Dimensional Optimization for Minimally Invasive Surgery Robot Based on Double Space and Kinematic Accuracy Reliability Index
View through CrossRef
Abstract
To improve the kinematic performance of the remote center mechanism for surgical robot, a double space index and kinematic accuracy reliability index are proposed to optimize the dimensional sizes of mechanism. First, the influence of the angular error on the position error and the operability of the remote center in the workspace are analyzed. The position error space and operability space index are weighted to establish the double space index. Second, a kinematic accuracy reliability index is established based on the influence of joint clearance on output position accuracy. Finally, the dimensional sizes of remote center adjustment mechanism and double parallelogram mechanism are optimized based on proposed optimization indices. Multipopulation genetic algorithm is used to obtain the optimal size parameters under the corresponding index. The optimized double space index is 56.7%, which is 56.5% higher than before optimization. The optimized kinematic accuracy reliability is 0.91, which is 22.9% higher than before optimization. The kinematic performance of remote center mechanism has been significantly improved after optimization.
Title: Dimensional Optimization for Minimally Invasive Surgery Robot Based on Double Space and Kinematic Accuracy Reliability Index
Description:
Abstract
To improve the kinematic performance of the remote center mechanism for surgical robot, a double space index and kinematic accuracy reliability index are proposed to optimize the dimensional sizes of mechanism.
First, the influence of the angular error on the position error and the operability of the remote center in the workspace are analyzed.
The position error space and operability space index are weighted to establish the double space index.
Second, a kinematic accuracy reliability index is established based on the influence of joint clearance on output position accuracy.
Finally, the dimensional sizes of remote center adjustment mechanism and double parallelogram mechanism are optimized based on proposed optimization indices.
Multipopulation genetic algorithm is used to obtain the optimal size parameters under the corresponding index.
The optimized double space index is 56.
7%, which is 56.
5% higher than before optimization.
The optimized kinematic accuracy reliability is 0.
91, which is 22.
9% higher than before optimization.
The kinematic performance of remote center mechanism has been significantly improved after optimization.
Related Results
Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
The robot null space : new uses for new robotic systems
The robot null space : new uses for new robotic systems
This doctoral thesis deals with the use of the robot redundancy to execute several tasks simultaneously at different levels of priority and its application to two different robotic...
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
Abstract
Background
Minimally invasive technique for esophagectomy has emerged as the standard of care for resectable esophageal...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Teori dan Praktik Kinematika Robot Lengan
Teori dan Praktik Kinematika Robot Lengan
Robot makin banyak diterapkan dalam dunia industri dan kehidupan sehari-hari. Robot dimanfaatkan untuk membantu pekerjaan manusia agar manusia dapat menyelesaikan pekerjaan lebih e...
Robot performance measurement and calibration using a 3D computer vision system
Robot performance measurement and calibration using a 3D computer vision system
SummaryPresent day robot systems are manufactured to perform within industry accepted tolerances. However, to use such systems for tasks requiring high precision, various methods o...
Rancang Bangun Kendali Robot Beroda menggunakan Sistem Android
Rancang Bangun Kendali Robot Beroda menggunakan Sistem Android
Robot merupakan salah satu bidang sedang banyak mendapatkan perhatian, tidak hanya di Indonesia tapi juga di dunia. Di Indonesia sendiri terdapat kontes robot yang sangat bergengsi...
The early results of Robotic surgeryin treating pancreatic and hepatobiliarydiseases at Binh Dan Hospital
The early results of Robotic surgeryin treating pancreatic and hepatobiliarydiseases at Binh Dan Hospital
Tóm tắt
Đặt vấn đề: Phẫu thuật nội soi đã được áp dụng phổ biến trong bệnh lý gan mật tụy. Gần đây, phẫu thuật nội soi robot hỗ trợ là một tiến bộ mới của phẫu thuật ống mật chủ, t...