Javascript must be enabled to continue!
Simultaneous Estimation of Atazanavir & Ritonavir in API & Marketed Formulations by Using RP-HPLC
View through CrossRef
Development and validation of RP-HPLC method for simultaneous estimation of Atazanavir and Ritonavir in their combined tablet dosage form. Atazanavir and Ritonavir are antiviral agents used in treatment of HIV. A simple, precise, rapid, accurate and cost-effective high- performance liquid chromatography (HPLC) method was successfully developed and validated for simultaneous estimation of Atazanavir and Ritonavir in their combined tablet dosage form. The selected mobile phase was Methanol: Phosphate Buffer in proportion 65:35 v/v respectively. The optimized columns used are C18 column, Symmetry and Zodiac column. X bridge C18 (4.6×150 mm, 5 µm) particle size was found to be ideal as it gave good peak shape and resolution at 1ml/min flow for Atazanavir and Ritonavir. In this study, the validation of Atazanavir and Ritonavir in API and marketed formulations were performed keeping in accordance with the parameters like system suitability, specificity, linearity, accuracy, precision (reproducibility & repeatability), robustness. The developed stability indicating method is capable for determination of impurities of Atazanavir and Ritonavir in combined tablet dosage form as well as individual dosage forms also. The method has been successfully validated according to ICH guidelines and the results obtained by using RP – HPLC are rapid, accurate and precise. The proposed methods were successfully applied for the analysis of synthetic mixtures and pharmaceutical formulations of Atazanavir and Ritonavir.
Title: Simultaneous Estimation of Atazanavir & Ritonavir in API & Marketed Formulations by Using RP-HPLC
Description:
Development and validation of RP-HPLC method for simultaneous estimation of Atazanavir and Ritonavir in their combined tablet dosage form.
Atazanavir and Ritonavir are antiviral agents used in treatment of HIV.
A simple, precise, rapid, accurate and cost-effective high- performance liquid chromatography (HPLC) method was successfully developed and validated for simultaneous estimation of Atazanavir and Ritonavir in their combined tablet dosage form.
The selected mobile phase was Methanol: Phosphate Buffer in proportion 65:35 v/v respectively.
The optimized columns used are C18 column, Symmetry and Zodiac column.
X bridge C18 (4.
6×150 mm, 5 µm) particle size was found to be ideal as it gave good peak shape and resolution at 1ml/min flow for Atazanavir and Ritonavir.
In this study, the validation of Atazanavir and Ritonavir in API and marketed formulations were performed keeping in accordance with the parameters like system suitability, specificity, linearity, accuracy, precision (reproducibility & repeatability), robustness.
The developed stability indicating method is capable for determination of impurities of Atazanavir and Ritonavir in combined tablet dosage form as well as individual dosage forms also.
The method has been successfully validated according to ICH guidelines and the results obtained by using RP – HPLC are rapid, accurate and precise.
The proposed methods were successfully applied for the analysis of synthetic mixtures and pharmaceutical formulations of Atazanavir and Ritonavir.
Related Results
Focus on slow rotators - first results from stellar occultations campaign on long-period asteroids
Focus on slow rotators - first results from stellar occultations campaign on long-period asteroids
<p><strong>Most asteroids are slow rotators &#160;</strong> &#160;&#160;&#160;&#160;&#160;...
Cometary Physics Laboratory: spectrophotometric experiments
Cometary Physics Laboratory: spectrophotometric experiments
<p><strong><span dir="ltr" role="presentation">1. Introduction</span></strong&...
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
<span style="font-size: 11pt; color: black; font-family: 'Times New Roman','serif'">ΠΗΛΙΝΑ ΙΓ&Delta...
Morphometry of an hexagonal pit crater in Pavonis Mons, Mars
Morphometry of an hexagonal pit crater in Pavonis Mons, Mars
<p><strong>Introduction:</strong></p>
<p>Pit craters are peculiar depressions found in almost every terrestria...
Un manoscritto equivocato del copista santo Theophilos († 1548)
Un manoscritto equivocato del copista santo Theophilos († 1548)
<p><font size="3"><span class="A1"><span style="font-family: 'Times New Roman','serif'">ΕΝΑ ΛΑΝ&...
A Touch of Space Weather - Outreach project for visually impaired students
A Touch of Space Weather - Outreach project for visually impaired students
<p><em><span data-preserver-spaces="true">'A Touch of Space Weather' is a project that brings space weather science into...
Ballistic landslides on comet 67P/Churyumov–Gerasimenko
Ballistic landslides on comet 67P/Churyumov–Gerasimenko
<p><strong>Introduction:</strong></p><p>The slow ejecta (i.e., with velocity lower than escape velocity) and l...
Stress transfer process in doublet events studied by numerical TREMOL simulations: Study case Ometepec 1982 Doublet.
Stress transfer process in doublet events studied by numerical TREMOL simulations: Study case Ometepec 1982 Doublet.
<pre class="western"><span><span lang="en-US">Earthquake doublets are a characteristic rupture <...

