Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of Hybrid III Leg Geometry on Upper Tibia Bending Moments

View through CrossRef
<div class="htmlview paragraph">The knee and ankle joint pivots of the Hybrid III dummy's leg are positioned in approximately the same orientation as the knee and ankle joint rotation centers of a human in a normal driving posture. However, the dummy's leg assembly is not simply a straight member between these two pivots. It is a zigzag-shaped solid link composed of one long straight section in the middle and short angled sections at either end, which form the pivots. The upper and lower tibia load cells are mounted on the straight middle section, making the upper tibia load cell location anterior to the line between the ankle and knee pivots and the lower tibia load cell location slightly posterior to the line between the pivots. Hence, an approximately vertical force on the foot can act along the line behind the upper tibia load cell and in front of the lower tibia load cell, creating bending moments. The upper tibia moment would bow the leg forward (negative Y moment by SAE J211 convention), and the lower tibia moment generated would bow the leg rearward (positive Y moment). Such spurious bending moments, particularly at the upper tibia, can be large enough to suggest a significant risk of proximal tibia fracture that likely would not exist in humans subjected to the same forces. Several instances of forward bending of the proximal tibia coincident with axial loading on the lower tibia have been identified among the data recorded in 64 km/h (40 mi/h) frontal offset crash tests conducted by the Insurance Institute for Highway Safety. The ratio of upper tibia bending moment to measured tibia axial force was approximately equal to the distance between the center of the upper tibia load cell and the line connecting the knee and ankle pivots. In addition, other measures recorded on the same leg indicated the proximal tibia bending was due predominantly to an upward force on the foot. This paper describes how the potentially erroneous indications of proximal tibia fracture risk were identified and suggests a method for estimating more realistic moments at the upper and lower load cell locations.</div>
Title: Effect of Hybrid III Leg Geometry on Upper Tibia Bending Moments
Description:
<div class="htmlview paragraph">The knee and ankle joint pivots of the Hybrid III dummy's leg are positioned in approximately the same orientation as the knee and ankle joint rotation centers of a human in a normal driving posture.
However, the dummy's leg assembly is not simply a straight member between these two pivots.
It is a zigzag-shaped solid link composed of one long straight section in the middle and short angled sections at either end, which form the pivots.
The upper and lower tibia load cells are mounted on the straight middle section, making the upper tibia load cell location anterior to the line between the ankle and knee pivots and the lower tibia load cell location slightly posterior to the line between the pivots.
Hence, an approximately vertical force on the foot can act along the line behind the upper tibia load cell and in front of the lower tibia load cell, creating bending moments.
The upper tibia moment would bow the leg forward (negative Y moment by SAE J211 convention), and the lower tibia moment generated would bow the leg rearward (positive Y moment).
Such spurious bending moments, particularly at the upper tibia, can be large enough to suggest a significant risk of proximal tibia fracture that likely would not exist in humans subjected to the same forces.
Several instances of forward bending of the proximal tibia coincident with axial loading on the lower tibia have been identified among the data recorded in 64 km/h (40 mi/h) frontal offset crash tests conducted by the Insurance Institute for Highway Safety.
The ratio of upper tibia bending moment to measured tibia axial force was approximately equal to the distance between the center of the upper tibia load cell and the line connecting the knee and ankle pivots.
In addition, other measures recorded on the same leg indicated the proximal tibia bending was due predominantly to an upward force on the foot.
This paper describes how the potentially erroneous indications of proximal tibia fracture risk were identified and suggests a method for estimating more realistic moments at the upper and lower load cell locations.
</div>.

Related Results

ANALISIS PENGARUH RADIUS BENDING PADA PROSES BENDING MENGGUNAKAN PELAT SPCC-SD TERHADAP PERUBAHAN STRUKTUR MIKRO
ANALISIS PENGARUH RADIUS BENDING PADA PROSES BENDING MENGGUNAKAN PELAT SPCC-SD TERHADAP PERUBAHAN STRUKTUR MIKRO
Paper ini membahas tentang pengaruh radius bending pada kualitas hasil bending dan pengaruhnya terhadap perubahan microstructure. Proses bending merupakan salah satu proses pembent...
Muscle Metabolism during Exercise in Hemiparetic Patients
Muscle Metabolism during Exercise in Hemiparetic Patients
1. A group of eight male patients with moderate hemiparesis was studied at rest and during 40 min of exercise on four occasions. Both two-leg and one-leg exercise were performed an...
Prevalence, Patterns and Associated Factors of Acute Tibia Plateau Fractures among Adults with Tibia Fractures in Uganda
Prevalence, Patterns and Associated Factors of Acute Tibia Plateau Fractures among Adults with Tibia Fractures in Uganda
Abstract Background: The Tibia plateau makes up one of the most critical load bearing articular surface in the human body. An injury to this vital anatomic region affects k...
SCF Equations for T/Y and K Square-to-Round Tubular Joint
SCF Equations for T/Y and K Square-to-Round Tubular Joint
Summary A parametric stress analysis of T/Y and K square-to-round tubular joints subjected to axial loads and in-plane and out-of-plane bending moments has been p...
Apparent Diffusion Coefficient Measurement of Myelofibrosis in Mouse Tibia v1
Apparent Diffusion Coefficient Measurement of Myelofibrosis in Mouse Tibia v1
The goal of this Co-Clinical Imaging Research Program (CIRP) pre-clinical imaging protocol (PIP) is to provide detailed description of key steps used to achieve a stated level of t...
PIP MRI Magnetization Transfer Ratio (MTR) Measurement of Myelofibrosis in Mouse Tibia v2
PIP MRI Magnetization Transfer Ratio (MTR) Measurement of Myelofibrosis in Mouse Tibia v2
The goal of this Co-Clinical Imaging Research Program (CIRP) pre-clinical imaging protocol (PIP) is to provide detailed description of key steps used to achieve a stated level of t...
PIP MRI Magnetization Transfer Ratio (MTR) Measurement of Myelofibrosis in Mouse Tibia v1
PIP MRI Magnetization Transfer Ratio (MTR) Measurement of Myelofibrosis in Mouse Tibia v1
The goal of this Co-Clinical Imaging Research Program (CIRP) pre-clinical imaging protocol (PIP) is to provide detailed description of key steps used to achieve a stated level of t...
Proton Density Fat Fraction (PDFF) Measurement of Myelofibrosis in Mouse Tibia v1
Proton Density Fat Fraction (PDFF) Measurement of Myelofibrosis in Mouse Tibia v1
This document details procedures for PDFF measurement in MF mouse tibia to achieve stated performance claims.In this profile PDFF values are expressed in “% units” on a 0 to 100% s...

Back to Top