Javascript must be enabled to continue!
Experimental study on ultrasonic cavitation intensity based on fluorescence analysis
View through CrossRef
Abstract
Ultrasonic cavitation effect has been widely used in mechanical engineering, chemical engineering, biomedicine, and many other fields. The quantitative characterization of ultrasonic cavitation intensity has always been a difficulty. Based on this, a fluorescence analysis method has been adopted to explore ultrasonic cavitation intensity in this paper. In the experiment of fluorescence intensity measurement, terephthalic acid (TA) was used as the fluorescent probe, ultrasonic power, ultrasonic frequency, and irradiation time were independent variables, and fluorescence intensity and fluorescence peak area were used as experimental results. The collapse of ultrasonic cavitation bubble will cause molecular bond breakage and release ·OH, and the non-fluorescent substance TA will form strong fluorescent substance TAOH with ·OH. The spectra of the treated samples were measured by an F-7000 fluorescence spectrophotometer. The results showed that the fluorescence intensity and fluorescence peak area increased rapidly after ultrasonic cavitation treatment, and then increased slowly with the increase of ultrasonic power, which gradually increased with the increase of irradiation time. They first decreased and then increased with the increase of ultrasonic frequency from 20 kHz to 40 kHz. This was due to the comprehensive influence of the changes of cavitation oscillation period, cavitation energy, and the number of cavitation bubbles caused by the variation of ultrasonic frequency. The irradiation time was the most influential factor, and the cavitation intensity of low frequency was higher overall. The fluorescence intensity and fluorescence peak area of the samples increased by 2-20 times after ultrasonic treatment, which could increase from 69.0 and 5238 to 1387 and 95451, respectively. After the irradiation time exceeded 25 min, the growth rate of fluorescence intensity slowed down, which was caused by the decrease of gas content and TA concentration in the solution. The study quantitatively characterized the cavitation intensity, reflecting the advantages of fluorescence analysis, and provided a basis for the further study of ultrasonic cavitation.
Title: Experimental study on ultrasonic cavitation intensity based on fluorescence analysis
Description:
Abstract
Ultrasonic cavitation effect has been widely used in mechanical engineering, chemical engineering, biomedicine, and many other fields.
The quantitative characterization of ultrasonic cavitation intensity has always been a difficulty.
Based on this, a fluorescence analysis method has been adopted to explore ultrasonic cavitation intensity in this paper.
In the experiment of fluorescence intensity measurement, terephthalic acid (TA) was used as the fluorescent probe, ultrasonic power, ultrasonic frequency, and irradiation time were independent variables, and fluorescence intensity and fluorescence peak area were used as experimental results.
The collapse of ultrasonic cavitation bubble will cause molecular bond breakage and release ·OH, and the non-fluorescent substance TA will form strong fluorescent substance TAOH with ·OH.
The spectra of the treated samples were measured by an F-7000 fluorescence spectrophotometer.
The results showed that the fluorescence intensity and fluorescence peak area increased rapidly after ultrasonic cavitation treatment, and then increased slowly with the increase of ultrasonic power, which gradually increased with the increase of irradiation time.
They first decreased and then increased with the increase of ultrasonic frequency from 20 kHz to 40 kHz.
This was due to the comprehensive influence of the changes of cavitation oscillation period, cavitation energy, and the number of cavitation bubbles caused by the variation of ultrasonic frequency.
The irradiation time was the most influential factor, and the cavitation intensity of low frequency was higher overall.
The fluorescence intensity and fluorescence peak area of the samples increased by 2-20 times after ultrasonic treatment, which could increase from 69.
0 and 5238 to 1387 and 95451, respectively.
After the irradiation time exceeded 25 min, the growth rate of fluorescence intensity slowed down, which was caused by the decrease of gas content and TA concentration in the solution.
The study quantitatively characterized the cavitation intensity, reflecting the advantages of fluorescence analysis, and provided a basis for the further study of ultrasonic cavitation.
Related Results
Research progress in hydrofoil cavitation prediction and suppression methods
Research progress in hydrofoil cavitation prediction and suppression methods
To reduce the adverse damage caused by cavitation phenomena to the hydraulic machinery, such as surface erosion of the equipment, increased mechanical vibration, and decreased serv...
Non-Spherical Cavitation Bubbles: A Review
Non-Spherical Cavitation Bubbles: A Review
Cavitation is a phase-change phenomenon from the liquid to the gas phase due to an increased flow velocity. As it causes severe erosion and noise, it is harmful to hydraulic machin...
Research on cavitation acoustic characteristics of centrifugal pump based on fluid-acoustic field coupling method
Research on cavitation acoustic characteristics of centrifugal pump based on fluid-acoustic field coupling method
In order to study the change rules of interior acoustic field with the development of cavitation, this article presented a method that through comparing the experiment results with...
The Cavitation Nuclei Transient Characteristics of Lennard-Jones Fluid in Cavitation Inception
The Cavitation Nuclei Transient Characteristics of Lennard-Jones Fluid in Cavitation Inception
Abstract
In the field of ocean engineering, cavitation is widespread, for the study of cavitation nuclei transient characteristics in cavitation inception, we app...
Optimization of a novel biomimetic vortex generator structure based on cavitation intensity and stability control
Optimization of a novel biomimetic vortex generator structure based on cavitation intensity and stability control
Cavitation phenomena in the fields of hydraulic machinery and underwater submersibles have brought numerous negative impacts, such as vibration noise and mechanical damage. To supp...
CFD INVESTIGATION OF TURBULENT WATER FLOW IN A PIPE ELBOW: ASSESSMENT OF CAVITATION RISK
CFD INVESTIGATION OF TURBULENT WATER FLOW IN A PIPE ELBOW: ASSESSMENT OF CAVITATION RISK
Cavitation represents the formation and subsequent collapse of vapor or gas bubbles in the vicinity of solid surfaces. Depending on the mechanism of initiation, cavitation can be c...
Design and investigation of metal oxide catalysts as cavitation agents for assisted-catalytic reactions
Design and investigation of metal oxide catalysts as cavitation agents for assisted-catalytic reactions
Conception et investigation de catalyseurs à base d'oxyde métallique comme agents de cavitation pour les réactions catalytiques
La génération de radicaux formés in ...
Study on Unsteady Cavitation Flow and Pressure Pulsation Characteristics in the Regulating Valve
Study on Unsteady Cavitation Flow and Pressure Pulsation Characteristics in the Regulating Valve
A combined numerical‐experiment investigation on the unsteady cavitation flow and pressure fluctuation characteristics in the regulating valves is conducted in this paper. The cavi...

