SU‐E‐T‐458: Impact of Parameters for Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer

View through CrossRef
Purpose:Different parameters Result in different plans. As the developing of volumetric modulated arc therapy for rectal cancer, the purpose of this study was to work out appropriate parameters for the optimization of rectal cancer.Methods:For ten cases which were optimized using Oncentra4.3 version, varying systematically the number of arcs, collimator angle and the delivery time to create different plans. Homogeneity in planning target volume, median dose in the organs at risk and number of monitor units were evaluated for statistical analysis. Measurements were performed with Delt4, taking the delivery time, and compared to the calculation by the gamma method.Results:Plans with collimator 45° were little superior to plans with collimator 0°. Single arc achieved lower homogeneous indices in the planning target volume compared with dual arc, but also requiring less monitor units per fraction dose than dual arc. Single arc needs less monitor units for the treatment; the measured delivery time was reduced from 4 min of dual arc to 2.5 min of single arc. All the plans could achieve good pass rate with gamma method.Conclusion:Some of the parameters have been found as the appropriate sets which can be used as standard for volumetric modulated arc therapy of rectal cancer.
Title: SU‐E‐T‐458: Impact of Parameters for Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer
Description:
Purpose:Different parameters Result in different plans.
As the developing of volumetric modulated arc therapy for rectal cancer, the purpose of this study was to work out appropriate parameters for the optimization of rectal cancer.
Methods:For ten cases which were optimized using Oncentra4.
3 version, varying systematically the number of arcs, collimator angle and the delivery time to create different plans.
Homogeneity in planning target volume, median dose in the organs at risk and number of monitor units were evaluated for statistical analysis.
Measurements were performed with Delt4, taking the delivery time, and compared to the calculation by the gamma method.
Results:Plans with collimator 45° were little superior to plans with collimator 0°.
Single arc achieved lower homogeneous indices in the planning target volume compared with dual arc, but also requiring less monitor units per fraction dose than dual arc.
Single arc needs less monitor units for the treatment; the measured delivery time was reduced from 4 min of dual arc to 2.
5 min of single arc.
All the plans could achieve good pass rate with gamma method.
Conclusion:Some of the parameters have been found as the appropriate sets which can be used as standard for volumetric modulated arc therapy of rectal cancer.

Related Results

Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Objectives: This study aimed to find the optimal radiotherapy VMAT plans, that achieved high conformity and homogeneity to the planned target volume (PTV), and minimize the dose to...
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...
Feasibility of 4D VMAT-CT
Feasibility of 4D VMAT-CT
Abstract Objective. Feasibility of three-dimensional (3D) tracking of volumetric modulated arc therapy (VMAT) based on VMAT–computed tomography (V...
Evaluation of Delta 4 system in patient specific QA for VMAT technique: Retrospective lung VMAT cases
Evaluation of Delta 4 system in patient specific QA for VMAT technique: Retrospective lung VMAT cases
Abstract The objective of this study was to evaluate the Delta 4 system for lung VMAT technique. The standard fields and VMAT plans were generated into the homogeneo...
Edoxaban and Cancer-Associated Venous Thromboembolism: A Meta-analysis of Clinical Trials
Edoxaban and Cancer-Associated Venous Thromboembolism: A Meta-analysis of Clinical Trials
Abstract Introduction Cancer patients face a venous thromboembolism (VTE) risk that is up to 50 times higher compared to individuals without cancer. In 2010, direct oral anticoagul...