Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Spectral Entropy and Bispectral Index as Measures of the Electroencephalographic Effects of Sevoflurane

View through CrossRef
Background Recently, entropy algorithms have been proposed as electroencephalographic measures of anesthetic drug effects. Datex-Ohmeda (Helsinki, Finland) introduced the Entropy Module, a new electroencephalographic monitor designed for measuring depth of anesthesia. The monitor calculates a state entropy (SE) computed over the frequency range of 0.8-32 Hz and a response entropy (RE) computed over the frequency range of 0.8-47 Hz. The authors investigated the dose-response relation of SE and RE during sevoflurane anesthesia in comparison with the Bispectral Index (BIS). Methods Sixteen patients were studied without surgical stimulus. Anesthesia was induced by sevoflurane inhalation with a tight-fitting facemask. Sevoflurane concentrations were increased and subsequently decreased and increased two to four times until the measurement was stopped and patients were intubated for surgery. The performances of SE, RE, and BIS to predict the estimated sevoflurane effect site concentration, obtained by simultaneous pharmacokinetic and pharmacodynamic modeling, were compared by calculating the correlation coefficients and the prediction probability. Results State entropy, RE, and BIS values decreased continuously over the observed concentration range of sevoflurane. Correlation coefficients were slightly but not significantly better for entropy parameters (0.87 +/- 0.09 and 0.86 +/- 0.10 for SE and RE, respectively) than for BIS (0.85 +/- 0.12). Calculating the prediction probability confirmed these results with a prediction probability of 0.84 +/- 0.05 and 0.82 +/- 0.06 for SE and RE, respectively, and 0.80 +/- 0.06 for BIS. Conclusion State entropy and RE seem to be useful electroencephalographic measures of sevoflurane drug effect.
Title: Spectral Entropy and Bispectral Index as Measures of the Electroencephalographic Effects of Sevoflurane
Description:
Background Recently, entropy algorithms have been proposed as electroencephalographic measures of anesthetic drug effects.
Datex-Ohmeda (Helsinki, Finland) introduced the Entropy Module, a new electroencephalographic monitor designed for measuring depth of anesthesia.
The monitor calculates a state entropy (SE) computed over the frequency range of 0.
8-32 Hz and a response entropy (RE) computed over the frequency range of 0.
8-47 Hz.
The authors investigated the dose-response relation of SE and RE during sevoflurane anesthesia in comparison with the Bispectral Index (BIS).
Methods Sixteen patients were studied without surgical stimulus.
Anesthesia was induced by sevoflurane inhalation with a tight-fitting facemask.
Sevoflurane concentrations were increased and subsequently decreased and increased two to four times until the measurement was stopped and patients were intubated for surgery.
The performances of SE, RE, and BIS to predict the estimated sevoflurane effect site concentration, obtained by simultaneous pharmacokinetic and pharmacodynamic modeling, were compared by calculating the correlation coefficients and the prediction probability.
Results State entropy, RE, and BIS values decreased continuously over the observed concentration range of sevoflurane.
Correlation coefficients were slightly but not significantly better for entropy parameters (0.
87 +/- 0.
09 and 0.
86 +/- 0.
10 for SE and RE, respectively) than for BIS (0.
85 +/- 0.
12).
Calculating the prediction probability confirmed these results with a prediction probability of 0.
84 +/- 0.
05 and 0.
82 +/- 0.
06 for SE and RE, respectively, and 0.
80 +/- 0.
06 for BIS.
Conclusion State entropy and RE seem to be useful electroencephalographic measures of sevoflurane drug effect.

Related Results

Entropy-guided sevoflurane administration during cardiopulmonary bypass surgery in the paediatric population
Entropy-guided sevoflurane administration during cardiopulmonary bypass surgery in the paediatric population
Background Maintaining optimal anesthetic depth during cardiopulmonary bypass (CPB) in pediatric patients is challenging due to altered physiology and unreliable conven...
Mechanical seal friction condition monitoring based on bispectral characteristics
Mechanical seal friction condition monitoring based on bispectral characteristics
Purpose The purpose of this paper is to investigate the monitoring of the friction condition of mechanical seals. ...
Sevoflurane inhibits Human umbilical vein endothelial cells migration by up-regulating VE-cadherin expression
Sevoflurane inhibits Human umbilical vein endothelial cells migration by up-regulating VE-cadherin expression
Abstract Background Sevoflurane is a commonly used inhalation anesthesia and is famous for rapid onset of action, less metabolism in vivo and fast recovery. The aim of thi...
Sevoflurane inhibits Human umbilical vein endothelial cells migration by up-regulating VE-cadherin expression
Sevoflurane inhibits Human umbilical vein endothelial cells migration by up-regulating VE-cadherin expression
Abstract Background Sevoflurane is a commonly used inhalation anesthesia and is famous for rapid onset of action, less metabolism in vivo and fast recovery. The aim of this...
Sevoflurane in Status Asthmaticus: A Case Report and Literature Review
Sevoflurane in Status Asthmaticus: A Case Report and Literature Review
Background Sevoflurane and other inhaled anesthetics are gradually entering provider awareness as rescue therapies for patients in refractory status asthmaticus. This paper docume...

Back to Top