Javascript must be enabled to continue!
Corticospinal volleys evoked by anodal and cathodal stimulation of the human motor cortex.
View through CrossRef
1. In fifteen neurologically normal subjects, corticospinal volleys evoked by transcranial stimulation of the motor cortex were recorded from the spinal cord using epidural electrodes in the high‐thoracic and low‐thoracic regions during surgery to correct scoliosis. 2. Anodal stimulation at the vertex produced complex corticospinal volleys that could be recorded at both sites, with multiple waves analogous to the D and I waves documented in animal experiments. These volleys were of higher amplitude when the cathode was 7 cm lateral to the vertex rather than 7 cm anterior. There were no differences in conduction time between the two recording sites for D and I waves, when these waves could be identified at the low‐thoracic site. 3. Anodal stimuli of 150 V commonly produced a descending volley containing a single peak at both recording sites. Modest increases in stimulus intensity to 225‐375 V produced a peak 0.8 ms in advance of the wave of lowest threshold in thirteen subjects and, in seven subjects, further increases produced an additional peak 1.7 ms in advance of the first‐recruited wave. The early peaks increased in size with stimulus intensity, replacing the first‐recruited wave. These results suggest that the site of impulse initiation with electrical stimulation of the motor cortex shifts from superficial cortex to deep structures, approximately 5 and 10‐11 cm below the cortex. These sites are probably the internal capsule and the cerebral peduncle. 4. With cathode at the vertex and anode over the ‘hand area’ the response of lowest threshold occurred at the latency of the anodal D wave but could not be recorded at the low‐thoracic site, suggesting that it was generated by the anode over the ‘hand area’. Slightly higher intensities induced a ‘cathodal D wave’ and still higher intensities produced late peaks at latencies of anodal I waves. These cathodal D and I waves involved axons innervating lumbar segments. There was no evidence that cathodal stimulation preferentially produced I waves. Cathodal stimulation at the vertex with the anode 7 cm anteriorly produced similar results: D waves were produced at relatively low intensities, but I waves appeared at relatively high stimulus intensities if at all.(ABSTRACT TRUNCATED AT 400 WORDS)
Title: Corticospinal volleys evoked by anodal and cathodal stimulation of the human motor cortex.
Description:
1.
In fifteen neurologically normal subjects, corticospinal volleys evoked by transcranial stimulation of the motor cortex were recorded from the spinal cord using epidural electrodes in the high‐thoracic and low‐thoracic regions during surgery to correct scoliosis.
2.
Anodal stimulation at the vertex produced complex corticospinal volleys that could be recorded at both sites, with multiple waves analogous to the D and I waves documented in animal experiments.
These volleys were of higher amplitude when the cathode was 7 cm lateral to the vertex rather than 7 cm anterior.
There were no differences in conduction time between the two recording sites for D and I waves, when these waves could be identified at the low‐thoracic site.
3.
Anodal stimuli of 150 V commonly produced a descending volley containing a single peak at both recording sites.
Modest increases in stimulus intensity to 225‐375 V produced a peak 0.
8 ms in advance of the wave of lowest threshold in thirteen subjects and, in seven subjects, further increases produced an additional peak 1.
7 ms in advance of the first‐recruited wave.
The early peaks increased in size with stimulus intensity, replacing the first‐recruited wave.
These results suggest that the site of impulse initiation with electrical stimulation of the motor cortex shifts from superficial cortex to deep structures, approximately 5 and 10‐11 cm below the cortex.
These sites are probably the internal capsule and the cerebral peduncle.
4.
With cathode at the vertex and anode over the ‘hand area’ the response of lowest threshold occurred at the latency of the anodal D wave but could not be recorded at the low‐thoracic site, suggesting that it was generated by the anode over the ‘hand area’.
Slightly higher intensities induced a ‘cathodal D wave’ and still higher intensities produced late peaks at latencies of anodal I waves.
These cathodal D and I waves involved axons innervating lumbar segments.
There was no evidence that cathodal stimulation preferentially produced I waves.
Cathodal stimulation at the vertex with the anode 7 cm anteriorly produced similar results: D waves were produced at relatively low intensities, but I waves appeared at relatively high stimulus intensities if at all.
(ABSTRACT TRUNCATED AT 400 WORDS).
Related Results
miR-409-3p represses
Cited2
at the evolutionary emergence of the callosal and corticospinal projections
miR-409-3p represses
Cited2
at the evolutionary emergence of the callosal and corticospinal projections
Abstract
Callosal projection neurons are a broad population of interhemispheric projection neurons that extend an axon across the corpus callosum...
Corticospinal volleys evoked by electrical stimulation of human motor cortex after withdrawal of volatile anaesthetics.
Corticospinal volleys evoked by electrical stimulation of human motor cortex after withdrawal of volatile anaesthetics.
1. In twenty‐two neurologically normal patients undergoing surgery for scoliosis, corticospinal volleys to transcranial electrical stimulation of the motor cortex were recorded fro...
Molecular specification of cortico-brainstem versus corticospinal projection neurons in development
Molecular specification of cortico-brainstem versus corticospinal projection neurons in development
Abstract
Skilled motor control requires precise connections between subcerebral projection neurons (SCPN) in the cerebral cortex and their approp...
A meta-analytical review of transcranial direct current stimulation parameters on upper limb motor learning in healthy older adults and people with Parkinson’s disease
A meta-analytical review of transcranial direct current stimulation parameters on upper limb motor learning in healthy older adults and people with Parkinson’s disease
Abstract
Current literature lacks consolidated evidence for the impact of stimulation parameters on the effects of transcranial direct current stimulation (tDCS) in ...
Concurrent Bilateral M1 and Anodal Cerebellar tDCS Effects on Learning of a Bimanual Video Game Task
Concurrent Bilateral M1 and Anodal Cerebellar tDCS Effects on Learning of a Bimanual Video Game Task
ABSTRACT
Purpose
The primary motor cortex (M1) and the cerebellum are important sites of processing for motor learning of...
Whole-hand water flow stimulation increases motor cortical excitability: a study of transcranial magnetic stimulation and movement-related cortical potentials
Whole-hand water flow stimulation increases motor cortical excitability: a study of transcranial magnetic stimulation and movement-related cortical potentials
Previous studies examining the influence of afferent stimulation on corticospinal excitability have demonstrated that the intensity of afferent stimulation and the nature of the af...
Motor cortex activation in hemiparetic stroke patients
Motor cortex activation in hemiparetic stroke patients
100
Little is known about the function of surviving motor cortex after hemiparetic stroke. Though the corticospinal tract may be damaged, function may persis...
Cathodal Transcranial Direct Current Stimulation Does Not Change Implicit Associations Against Alcohol in Alcohol Use Disorder: A Preregistered Clinical Trial
Cathodal Transcranial Direct Current Stimulation Does Not Change Implicit Associations Against Alcohol in Alcohol Use Disorder: A Preregistered Clinical Trial
ABSTRACTAddictive behaviour is shaped by the dynamic interaction of implicit, bottom‐up and explicit, top‐down cognitive processes. In alcohol use disorder (AUD), implicit alcohol‐...

