Javascript must be enabled to continue!
Picosecond time-resolved pump-probe XUV absorption L-edge spectroscopy
View through CrossRef
We present what we believe to be the first measurements of broadband XUV absorption spectroscopy with picosecond time scale resolution. A 10-Hz, 60 mJ 100-fs laser system is used to create a quasi-continuum of XUV radiation (30 Å < λ < 300 Å) from a gold plasmas to act as a probe source. The temporal duration of the probe is typically on the order of 20 ps but can be made shorter or longer by varying the laser parameters.1 Part of the 100-fs laser beam also provides a delta-function pump beam to heat a sample onto which the XUV probe source is focused by a novel XUV imaging optics. Time-resolved results are gathered by two different methods: 1) a variable delay between the pump laser and the probe XUV source is used to collect spatially-resolved spectra of the sample's absorption at different times during the laser heating and 2) a unique jitter-free x-ray streak camera2 developed at the Center for Ultrafast Optical Science is used to obtain temporally-resolved absorption spectra. This broadband time-resolved absorption spectroscopy technique offers a very interesting and flexible alternative to synchrotrons for experiments such as time-resolved EXAFS, chemical dynamics and ion characterization in laser ablation plumes.
Title: Picosecond time-resolved pump-probe XUV absorption L-edge spectroscopy
Description:
We present what we believe to be the first measurements of broadband XUV absorption spectroscopy with picosecond time scale resolution.
A 10-Hz, 60 mJ 100-fs laser system is used to create a quasi-continuum of XUV radiation (30 Å < λ < 300 Å) from a gold plasmas to act as a probe source.
The temporal duration of the probe is typically on the order of 20 ps but can be made shorter or longer by varying the laser parameters.
1 Part of the 100-fs laser beam also provides a delta-function pump beam to heat a sample onto which the XUV probe source is focused by a novel XUV imaging optics.
Time-resolved results are gathered by two different methods: 1) a variable delay between the pump laser and the probe XUV source is used to collect spatially-resolved spectra of the sample's absorption at different times during the laser heating and 2) a unique jitter-free x-ray streak camera2 developed at the Center for Ultrafast Optical Science is used to obtain temporally-resolved absorption spectra.
This broadband time-resolved absorption spectroscopy technique offers a very interesting and flexible alternative to synchrotrons for experiments such as time-resolved EXAFS, chemical dynamics and ion characterization in laser ablation plumes.
Related Results
Studies of 1fs scale dynamics in atoms and molecules
Studies of 1fs scale dynamics in atoms and molecules
Coherent light pulses of few to hundreds of femtoseconds (fs) duration haveprolically served the eld of ultrafast phenomena. While fs pulses addressmainly dynamics of nuclear motio...
Control over Extreme-Ultraviolet High-Harmonic Generation from Gases and Solids
Control over Extreme-Ultraviolet High-Harmonic Generation from Gases and Solids
The light source that has revolutionized attosecond science over the last decades is based on the process of high-harmonic generation (HHG), which is a unique method to generate a ...
Histological investigation of picosecond laser-toning and fractional laser therapy
Histological investigation of picosecond laser-toning and fractional laser therapy
Background and Aims: Rejuvenation therapy using picosecond pulse laser and picosecond pulsed fractional therapy with a fractional lens have been performed with clinical effects eva...
Extreme-ultraviolet and nonlinear spectroscopy of thin-film functional materials
Extreme-ultraviolet and nonlinear spectroscopy of thin-film functional materials
This thesis explores different aspects of extreme-ultraviolet (XUV) and nonlinear spectroscopy and applies them to several relevant thin film materials. Both of these rely on ultra...
Magic graphs
Magic graphs
DE LA TESIS<br/>Si un graf G admet un etiquetament super edge magic, aleshores G es diu que és un graf super edge màgic. La tesis està principalment enfocada a l'estudi del c...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps, from fairly recent test data are in conflict with traditional relationships. Additional testing is in progres...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps from fairly recent test data are in conflict with traditional relationships. Additional testing is in progress...

