Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Effect of Systemic Nicotine on Osseointegration of Titanium Implants in the Rat Femur

View through CrossRef
Abstract The purpose of this study was to determine whether high levels of plasma nicotine, delivered via subcutaneously placed mini-osmotic pumps, had an effect on bone development and osseointegration of a titanium implant in rat femurs in both the short and long term. In this study, we hypothesized that systemic nicotine may not affect bone development, but may affect osseointegration in both the short and long term. Thirty rats were assigned to 4 groups. Group 1 (n  =  10) was subdivided into 2 groups, which both received nicotine during the duration of the experiment. Half of the group (n  =  5) was sacrificed at 2 weeks after implant placement, and the other half (n  =  5) was sacrificed at 4 weeks after implant placement. Group 2 (n  =  10) was treated identically; however, this group was given saline placebo rather than nicotine. Nicotine/saline was administered via subcutaneous mini-osmotic pumps. Serum analysis was assessed biweekly and weight was assessed weekly. Implant placement consisted of mini-implant placement in the femur of the rats under general anesthesia. After sacrifice, the femurs were harvested and analyzed. Biomechanical push-in test was used to determine the degree of osseointegration by evaluating the breakpoint load. Micro-CT was performed on the femurs of the remaining 10 rats to determine the bone density and architecture. Micro-CT showed no significant difference in bone morphometric analysis. Push-in test showed significant difference in axial load force required to dislodge the implant between the nicotine-treated and control rats both at 2 and at 4 weeks after implant placement. The evidence indicates that while there was no significant difference in bone development and remodeling with exposure to systemic nicotine, there was a significant difference in bone wound healing, specifically with the osseointegration of titanium implants at both 2 and 4 weeks after implant placement. In conclusion, systemic nicotine may have a significant impact on the osseointegration of implants in the rat femur. Additional studies need to be conducted to further understand the specific way in which nicotine adversely affects wound healing on the molecular level.
Title: The Effect of Systemic Nicotine on Osseointegration of Titanium Implants in the Rat Femur
Description:
Abstract The purpose of this study was to determine whether high levels of plasma nicotine, delivered via subcutaneously placed mini-osmotic pumps, had an effect on bone development and osseointegration of a titanium implant in rat femurs in both the short and long term.
In this study, we hypothesized that systemic nicotine may not affect bone development, but may affect osseointegration in both the short and long term.
Thirty rats were assigned to 4 groups.
Group 1 (n  =  10) was subdivided into 2 groups, which both received nicotine during the duration of the experiment.
Half of the group (n  =  5) was sacrificed at 2 weeks after implant placement, and the other half (n  =  5) was sacrificed at 4 weeks after implant placement.
Group 2 (n  =  10) was treated identically; however, this group was given saline placebo rather than nicotine.
Nicotine/saline was administered via subcutaneous mini-osmotic pumps.
Serum analysis was assessed biweekly and weight was assessed weekly.
Implant placement consisted of mini-implant placement in the femur of the rats under general anesthesia.
After sacrifice, the femurs were harvested and analyzed.
Biomechanical push-in test was used to determine the degree of osseointegration by evaluating the breakpoint load.
Micro-CT was performed on the femurs of the remaining 10 rats to determine the bone density and architecture.
Micro-CT showed no significant difference in bone morphometric analysis.
Push-in test showed significant difference in axial load force required to dislodge the implant between the nicotine-treated and control rats both at 2 and at 4 weeks after implant placement.
The evidence indicates that while there was no significant difference in bone development and remodeling with exposure to systemic nicotine, there was a significant difference in bone wound healing, specifically with the osseointegration of titanium implants at both 2 and 4 weeks after implant placement.
In conclusion, systemic nicotine may have a significant impact on the osseointegration of implants in the rat femur.
Additional studies need to be conducted to further understand the specific way in which nicotine adversely affects wound healing on the molecular level.

Related Results

Techniques to Remove Press-Fit Osseointegration Implants
Techniques to Remove Press-Fit Osseointegration Implants
Background: Transcutaneous osseointegration for amputees (TOFA) has proven to consistently, significantly improve the quality of life and...
The Transfer of Nicotine from Nicotine Salts to Mainstream Smoke
The Transfer of Nicotine from Nicotine Salts to Mainstream Smoke
Abstract Transfer of nicotine to mainstream smoke was measured for Reference cigarettes made with the addition of 20 -40 mg of seven different nicotine salts, d- and...
Rodent models for nicotine withdrawal
Rodent models for nicotine withdrawal
Background: Animal models are critical to improve our understanding of the neuronal mechanisms underlying nicotine withdrawal. Nicotine dependence in rodents ca...
Runahead threads
Runahead threads
Los temas de investigación sobre multithreading han ganado mucho interés en la arquitectura de computadores con la aparición de procesadores multihilo y multinucleo. Los procesador...

Back to Top