Effectiveness of an Endotracheal Tube Adjustable Stabilizing Set to Prevent Unplanned Extubation in Preterm Infants: A Quasi-experimental Study
View through CrossRef
Preterm infants born before 34 weeks of gestation often face respiratory challenges and may require resuscitation with an endotracheal tube and ventilator support. Unplanned extubation is a common problem for such infants, affecting their care and outcomes. This quasi-experimental study compared the incidence of unplanned extubation, stability of vital signs and oxygen saturation between a control group (n = 24) receiving routine care in a neonatal intensive care unit and an experimental group (n = 24) receiving routine care along with the use of the Endotracheal Tube Adjustable Stabilizing Set, developed by the researchers. The latter set comprises an endotracheal tube-holding cap, head-locked pillows, and an oxygen meter. Data were analyzed using descriptive statistics, t-tests, chi-square tests, and Fisher’s exact tests.
Results show that the control group had an average tracheal tube insertion time of 78.94 hours, while the experimental group had an average of 39.35 hours. The incidence of unplanned extubation was 33.33% (8 cases) in the control group and 4.17% (1 case) in the experimental group. The unplanned extubation rate per 100 ventilator days was 4.41 times in the experimental group, significantly less than in the control group (23.84 times). The experimental group also exhibited significantly more time spent on vital signs and oxygen saturation within normal limits than the control group. In conclusion, using the Endotracheal Tube Adjustable Stabilizing Set in neonatal care can improve patient outcomes by reducing the incidence of unplanned extubation and stabilizing vital signs. This set has passed patentability evaluation for product design and enhances neonatal care by stabilizing endotracheal tubes, reducing slippage, and helping nurses provide more effective care. However, further testing in different settings with larger sample sizes and an equal average tracheal tube insertion time between the two groups is recommended to validate these findings.
Thailand Nursing and Midwifery Council
Title: Effectiveness of an Endotracheal Tube Adjustable Stabilizing Set to Prevent Unplanned Extubation in Preterm Infants: A Quasi-experimental Study
Description:
Preterm infants born before 34 weeks of gestation often face respiratory challenges and may require resuscitation with an endotracheal tube and ventilator support.
Unplanned extubation is a common problem for such infants, affecting their care and outcomes.
This quasi-experimental study compared the incidence of unplanned extubation, stability of vital signs and oxygen saturation between a control group (n = 24) receiving routine care in a neonatal intensive care unit and an experimental group (n = 24) receiving routine care along with the use of the Endotracheal Tube Adjustable Stabilizing Set, developed by the researchers.
The latter set comprises an endotracheal tube-holding cap, head-locked pillows, and an oxygen meter.
Data were analyzed using descriptive statistics, t-tests, chi-square tests, and Fisher’s exact tests.
Results show that the control group had an average tracheal tube insertion time of 78.
94 hours, while the experimental group had an average of 39.
35 hours.
The incidence of unplanned extubation was 33.
33% (8 cases) in the control group and 4.
17% (1 case) in the experimental group.
The unplanned extubation rate per 100 ventilator days was 4.
41 times in the experimental group, significantly less than in the control group (23.
84 times).
The experimental group also exhibited significantly more time spent on vital signs and oxygen saturation within normal limits than the control group.
In conclusion, using the Endotracheal Tube Adjustable Stabilizing Set in neonatal care can improve patient outcomes by reducing the incidence of unplanned extubation and stabilizing vital signs.
This set has passed patentability evaluation for product design and enhances neonatal care by stabilizing endotracheal tubes, reducing slippage, and helping nurses provide more effective care.
However, further testing in different settings with larger sample sizes and an equal average tracheal tube insertion time between the two groups is recommended to validate these findings.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Cardiovascular Malformations Among Preterm Infants
Cardiovascular Malformations Among Preterm Infants
Objective. Preterm birth and cardiovascular malformations are the 2 most common causes of neonatal and infant death, but there are no published population-based reports on the rela...
Analysis of factors influencing unplanned extubation in children and implementation of nursing strategies (Preprint)
Analysis of factors influencing unplanned extubation in children and implementation of nursing strategies (Preprint)
BACKGROUND
Unplanned extubation (UEX) serves as a crucial indicator for monitoring the quality of nursing care and can result in irreversible harm, impactin...
Predictive factors of extubation failure in pediatric cardiac intensive care unit: A single-center retrospective study from Thailand
Predictive factors of extubation failure in pediatric cardiac intensive care unit: A single-center retrospective study from Thailand
Introduction/objectiveExtubation failure increases morbidity and mortality in pediatric cardiac patients, a unique population including those with congenital heart disease or acqui...
Effectiveness and Safety of Extubation before Reversal of Neuromuscular Blockade versus Traditional Technique in Providing Smooth Extubation
Effectiveness and Safety of Extubation before Reversal of Neuromuscular Blockade versus Traditional Technique in Providing Smooth Extubation
Background:
Traditional extubation often leads to bucking, coughing, and undesirable hemodynamic changes. Extubation just before administering reversal could re...
Risk factors and outcomes associated with unplanned intraoperative extubation of the pediatric surgical patient: An analysis of the NSQIP‐P database
Risk factors and outcomes associated with unplanned intraoperative extubation of the pediatric surgical patient: An analysis of the NSQIP‐P database
AbstractBackgroundUnplanned intraoperative extubation is a rare but potentially catastrophic safety event. Inadvertent extubation in the neonatal and pediatric critical care settin...
Effects of preterm birth and bronchopulmonary dysplasia on infants’ pulmonary function: A cohort study of 117 infants
Effects of preterm birth and bronchopulmonary dysplasia on infants’ pulmonary function: A cohort study of 117 infants
Abstract
Background
Despite improved preterm infant survival rates in recent years, the increasing prevalence of preterm birth requires ongoing attention to associated ris...
FAKTOR YANG BERHUBUNGAN DENGAN KEJADIAN PERSALINAN PREMATUR DI RSUD DR SOETOMO
FAKTOR YANG BERHUBUNGAN DENGAN KEJADIAN PERSALINAN PREMATUR DI RSUD DR SOETOMO
AbstrakLatar Belakang: Secara global, persalinan preterm menjadi penyebab utama kematian neonatus usia dini 0-7 hari pertama kehidupan dengan menimbulkan dampak morbiditas yang tin...