Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Design of prototype two element optically stimulated luminescence dosimeter badge for eye lens monitoring

View through CrossRef
A prototype two element eye lens dosimeter badge based on highly sensitive α-Al 2 O 3 :C optically stimulated luminescence dosimeters (OSLDs) was designed and developed. The badge consists of a plastic card in which two thin α-Al 2 O 3 :C optically stimulated luminescence (OSL) discs are placed. The OSLDs in the plastic card (when inserted into plastic cassette) are covered with energy compensation filters made up of 0.3 mm thick Cu and 1.35 mm thick Teflon discs positioned symmetrically on both sides of the dosimeter. The OSLD badge is useful for monitoring doses from photons and beta particles. In this paper, theoretical studies using Monte Carlo method as well as using the analytical technique have been performed to study the energy response of the bare α-Al 2 O 3 :C based disc dosimeters. These dosimeter discs have been found to exhibit over-response by a factor of ~ 3.4 at ~ 33 keV photon energy, whereas, beyond 80 keV photon energy, the response is nearly energy independent. Studies have also been performed to find the energy response of the α-Al 2 O 3 :C disc dosimeters under different metal filters, viz., Al, Cu, Sn etc., and under various thicknesses of Teflon. From theoretical simulations, it has been found that 0.3 mm thick Cu is sufficient to correct the over-response in lower energy region within acceptable limits. Further, Teflon disc (DuPont, USA) having thickness of 1.35 mm is found to be the optimized choice as filter for the second dosimeter disc. It is worth mentioning that the ratio of the response of the OSL disc under Teflon to that under Cu filter indicates average energy of X-ray photons and same is used to correct the over-response as well as to estimate the quantity H p (3). Also for higher photon energy region, the readout of the dosimeter disc under Teflon filter directly measures the quantity H p (3). Same holds true for beta particles having maximum beta energy, E max beyond 0.7 MeV.
Title: Design of prototype two element optically stimulated luminescence dosimeter badge for eye lens monitoring
Description:
A prototype two element eye lens dosimeter badge based on highly sensitive α-Al 2 O 3 :C optically stimulated luminescence dosimeters (OSLDs) was designed and developed.
The badge consists of a plastic card in which two thin α-Al 2 O 3 :C optically stimulated luminescence (OSL) discs are placed.
The OSLDs in the plastic card (when inserted into plastic cassette) are covered with energy compensation filters made up of 0.
3 mm thick Cu and 1.
35 mm thick Teflon discs positioned symmetrically on both sides of the dosimeter.
The OSLD badge is useful for monitoring doses from photons and beta particles.
In this paper, theoretical studies using Monte Carlo method as well as using the analytical technique have been performed to study the energy response of the bare α-Al 2 O 3 :C based disc dosimeters.
These dosimeter discs have been found to exhibit over-response by a factor of ~ 3.
4 at ~ 33 keV photon energy, whereas, beyond 80 keV photon energy, the response is nearly energy independent.
Studies have also been performed to find the energy response of the α-Al 2 O 3 :C disc dosimeters under different metal filters, viz.
, Al, Cu, Sn etc.
, and under various thicknesses of Teflon.
From theoretical simulations, it has been found that 0.
3 mm thick Cu is sufficient to correct the over-response in lower energy region within acceptable limits.
Further, Teflon disc (DuPont, USA) having thickness of 1.
35 mm is found to be the optimized choice as filter for the second dosimeter disc.
It is worth mentioning that the ratio of the response of the OSL disc under Teflon to that under Cu filter indicates average energy of X-ray photons and same is used to correct the over-response as well as to estimate the quantity H p (3).
Also for higher photon energy region, the readout of the dosimeter disc under Teflon filter directly measures the quantity H p (3).
Same holds true for beta particles having maximum beta energy, E max beyond 0.
7 MeV.

Related Results

METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
Relevance: The article discusses one of the ways to improve the DRG-05M dosimeter in brachytherapy by using new components and technologies in an improved scheme, which includes mo...
METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
METHODS FOR IMPROVING THE DRG-05M DOSIMETER IN BRACHYTHERAPY
Relevance: The article discusses one of the ways to improve the DRG-05M dosimeter in brachytherapy by using new components and technologies in an improved scheme, which includes m...
Badge-Type Noise Dosimeters Used in the Mining Industry
Badge-Type Noise Dosimeters Used in the Mining Industry
Currently, a number of manufacturers have developed and made commercially available badge-type (cordless) noise dosimeters. Previous studies conducted by the Mine Safety and Health...
Eye lens dose measurement in patients during brain arteriovenous malformation interventional neuro-radiology procedure
Eye lens dose measurement in patients during brain arteriovenous malformation interventional neuro-radiology procedure
Brain arteriovenous malformation (AVM) interventional neuroradiology (INR) is a complicated procedure which the patients may receive the high radiation dose exceeding the threshold...
Photodosimeter Badge System
Photodosimeter Badge System
The Committee on Phototherapy in the Newborn of the National Academy of Sciences has recommended10 development of a compact system to continuously measure radiant energy exposure o...
Development of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Development of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for p...
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Introduction. The structural approach to studying the mechanism of accommodation and its age-related changes focuses on analyzing morphometric parameters (size, shape, and position...

Back to Top