Incidental non-infectious masses on cardiac implantable electronic device leads
View through CrossRef
Abstract
Introduction
Incidentally detected masses on the leads of cardiac implantable electronic devices (CIED) present a clinical challenge, raising suspicion of infective device endocarditis. Data on the prevalence of such findings are scarce and outdated.
Purpose
Our aim was to determine the prevalence and evaluate predisposing clinical factors of incidental non-infectious CIED lead masses during transoesophageal echocardiography (TOE).
Methods
In this retrospective single-centre study, we analysed all TOE examinations performed in patients with CIED leads between January 2010 and November 2023. Patients with suspected or confirmed infectious endocarditis were excluded from this study. Patients with and without incidental non-infectious lead masses were compared regarding clinical characteristics, anticoagulation, type of CIED, and indication for TOE.
Results
In total, 120 patients with CIED were included. Twenty-five patients (20,8%) presented with non-infectious CIED lead masses. Laboratory findings and cardiovascular risk factors, such as arterial hypertension, dyslipidaemia, diabetes mellitus or chronic kidney disease did not differ significantly between both groups. Moreover, no association was observed between the incidence of CIED lead masses and the type of CIED implanted. Of notice, patients without therapeutic anticoagulation had significantly higher prevalence of CIED lead masses (OR 2.59, 95% CI: 1.04-6.46.; p=0.02), whereas the distribution of CHA2DS2-VASc scores did not differ significantly between both groups.
Conclusion
Non-infectious CIED lead masses in TOE is a frequent incidental finding. The absence of the oral anticoagulation seems to be the only clinical risk factor for such finding in our study, suggesting possible thrombogenic etiology.
The high prevalence of incidental non-infectious lead masses should be kept in mind in order to avoid overdiagnosis of CIED infection and unnecessary lead extraction.
Oxford University Press (OUP)
Title: Incidental non-infectious masses on cardiac implantable electronic device leads
Description:
Abstract
Introduction
Incidentally detected masses on the leads of cardiac implantable electronic devices (CIED) present a clinical challenge, raising suspicion of infective device endocarditis.
Data on the prevalence of such findings are scarce and outdated.
Purpose
Our aim was to determine the prevalence and evaluate predisposing clinical factors of incidental non-infectious CIED lead masses during transoesophageal echocardiography (TOE).
Methods
In this retrospective single-centre study, we analysed all TOE examinations performed in patients with CIED leads between January 2010 and November 2023.
Patients with suspected or confirmed infectious endocarditis were excluded from this study.
Patients with and without incidental non-infectious lead masses were compared regarding clinical characteristics, anticoagulation, type of CIED, and indication for TOE.
Results
In total, 120 patients with CIED were included.
Twenty-five patients (20,8%) presented with non-infectious CIED lead masses.
Laboratory findings and cardiovascular risk factors, such as arterial hypertension, dyslipidaemia, diabetes mellitus or chronic kidney disease did not differ significantly between both groups.
Moreover, no association was observed between the incidence of CIED lead masses and the type of CIED implanted.
Of notice, patients without therapeutic anticoagulation had significantly higher prevalence of CIED lead masses (OR 2.
59, 95% CI: 1.
04-6.
46.
; p=0.
02), whereas the distribution of CHA2DS2-VASc scores did not differ significantly between both groups.
Conclusion
Non-infectious CIED lead masses in TOE is a frequent incidental finding.
The absence of the oral anticoagulation seems to be the only clinical risk factor for such finding in our study, suggesting possible thrombogenic etiology.
The high prevalence of incidental non-infectious lead masses should be kept in mind in order to avoid overdiagnosis of CIED infection and unnecessary lead extraction.
Related Results
AI and Incidental Findings
AI and Incidental Findings
Photo by Accuray on Unsplash
INTRODUCTION
Delayed and missed follow-up on incidental findings threatens patient health and is a major financial risk for healthcare systems. The hea...
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Abstract
Background
Urrets-Zavalia syndrome is a condition that arises after eye surgery, often linked to increased intraocular pressure followin...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Cardiac Myxoma Post-Transseptal Ablation: Coincidence or Causation?
Cardiac Myxoma Post-Transseptal Ablation: Coincidence or Causation?
Background: Cardiac myxomas are benign cardiac neoplasms usually found solitarily located within a single cardiac chamber, most commonly in the left atrium. With no established cau...
Implantable antennas for biomedical applications: a systematic review
Implantable antennas for biomedical applications: a systematic review
AbstractThis review presents an in-depth examination of implantable antennas for various biomedical purposes. The development of implantable antennas, including their designs, mate...
Whole-body magnetic resonance imaging (WB-MRI) with diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in prostate cancer: Prevalence and clinical significance of incidental findings
Whole-body magnetic resonance imaging (WB-MRI) with diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in prostate cancer: Prevalence and clinical significance of incidental findings
Objective:
Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) is now recommended as a first-line staging modality in prostate c...
Whole-body magnetic resonance imaging (WB-MRI) with diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in prostate cancer: Prevalence and clinical significance of incidental findings
Whole-body magnetic resonance imaging (WB-MRI) with diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in prostate cancer: Prevalence and clinical significance of incidental findings
Abstract
Background
Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) is now recommended as a first-line staging modality in prostate c...
Impact of Chronotropic Incompetence and Correlation with Exercise Tolerance in Patients with Implantable Cardiac Devices Undergoing a Phase II Cardiac Rehabilitation Program
Impact of Chronotropic Incompetence and Correlation with Exercise Tolerance in Patients with Implantable Cardiac Devices Undergoing a Phase II Cardiac Rehabilitation Program
Objective: Since patients with implantable cardiac devices tend to develop chronotropic incompetence (CI) associated with the effect of the device itself or the pharmacological eff...