Javascript must be enabled to continue!
Fluid Structure Interaction With Contact Surface Methodology for Evaluation of Endovascular Carotid Implants for Drug-Resistant Hypertension Treatment
View through CrossRef
Drug-resistant hypertensive patients may be treated by mechanical stimulation of stretch-sensitive baroreceptors located in the sinus of carotid arteries. To evaluate the efficacy of endovascular devices to stretch the carotid sinus such that the induced strain might trigger baroreceptors to increase action potential firing rate and thereby reduce systemic blood pressure, numerical simulations were conducted of devices deployed in subject-specific carotid models. Two models were chosen—a typical physiologic carotid and a diminutive atypical physiologic model representing a clinically worst case scenario—to evaluate the effects of device deployment in normal and extreme cases, respectively. Based on the anatomical dimensions of the carotids, two different device sizes were chosen out of five total device sizes available. A fluid structure interaction (FSI) simulation methodology with contact surface between the device and the arterial wall was implemented for resolving the stresses and strains induced by device deployment. Results indicate that device deployment in the carotid sinus of the physiologic model induces an increase of 2.5% and 7.5% in circumferential and longitudinal wall stretch, respectively, and a maximum of 54% increase in von Mises arterial stress at the sinus wall baroreceptor region. The second device, deployed in the diminutive carotid model, induces an increase of 6% in both circumferential and longitudinal stretch and a 50% maximum increase in von Mises stress at the sinus wall baroreceptor region. Device deployment has a minimal effect on blood-flow patterns, indicating that it does not adversely affect carotid bifurcation hemodynamics in the physiologic model. In the smaller carotid model, deployment of the device lowers wall shear stress at sinus by 16% while accelerating flow entering the external carotid artery branch. Our FSI simulations of carotid arteries with deployed device show that the device induces localized increase in wall stretch at the sinus, suggesting that this will activate baroreceptors and subsequently may control hypertension in drug-resistant hypertensive patients, with no consequential deleterious effects on the carotid sinus hemodynamics.
Title: Fluid Structure Interaction With Contact Surface Methodology for Evaluation of Endovascular Carotid Implants for Drug-Resistant Hypertension Treatment
Description:
Drug-resistant hypertensive patients may be treated by mechanical stimulation of stretch-sensitive baroreceptors located in the sinus of carotid arteries.
To evaluate the efficacy of endovascular devices to stretch the carotid sinus such that the induced strain might trigger baroreceptors to increase action potential firing rate and thereby reduce systemic blood pressure, numerical simulations were conducted of devices deployed in subject-specific carotid models.
Two models were chosen—a typical physiologic carotid and a diminutive atypical physiologic model representing a clinically worst case scenario—to evaluate the effects of device deployment in normal and extreme cases, respectively.
Based on the anatomical dimensions of the carotids, two different device sizes were chosen out of five total device sizes available.
A fluid structure interaction (FSI) simulation methodology with contact surface between the device and the arterial wall was implemented for resolving the stresses and strains induced by device deployment.
Results indicate that device deployment in the carotid sinus of the physiologic model induces an increase of 2.
5% and 7.
5% in circumferential and longitudinal wall stretch, respectively, and a maximum of 54% increase in von Mises arterial stress at the sinus wall baroreceptor region.
The second device, deployed in the diminutive carotid model, induces an increase of 6% in both circumferential and longitudinal stretch and a 50% maximum increase in von Mises stress at the sinus wall baroreceptor region.
Device deployment has a minimal effect on blood-flow patterns, indicating that it does not adversely affect carotid bifurcation hemodynamics in the physiologic model.
In the smaller carotid model, deployment of the device lowers wall shear stress at sinus by 16% while accelerating flow entering the external carotid artery branch.
Our FSI simulations of carotid arteries with deployed device show that the device induces localized increase in wall stretch at the sinus, suggesting that this will activate baroreceptors and subsequently may control hypertension in drug-resistant hypertensive patients, with no consequential deleterious effects on the carotid sinus hemodynamics.
Related Results
Pharmacogenomics and the Concept of Personalized Medicine for the Management of Hypertension
Pharmacogenomics and the Concept of Personalized Medicine for the Management of Hypertension
Hypertension poses a significant global burden due to low adherence to antihypertensive medications. Hypertension treatment aims to bring blood pressure within physiological ranges...
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
AbstractIntroductionIn patients with 70% to 99% diameter carotid artery stenosis cerebral blood flow reserve may be protective of future ischemic cerebral events. Reserve cerebral ...
Correlation Between Carotid Plaque Location And Carotid Blood Flow Dynamics
Correlation Between Carotid Plaque Location And Carotid Blood Flow Dynamics
Abstract
Purpose: This study was aimed to investigate the influence of carotid hemodynamics in common carotid artery (CCA) and internal carotid artery (ICA) on carotid plaq...
CORRELATION STUDY OF CAROTID ATHEROSCLEROSIS AND SERUM HIGH SENSITIVITY C-REACTIVE PROTEIN LEVELS IN ELDERLY HYPERTENSIVE PATIENTS
CORRELATION STUDY OF CAROTID ATHEROSCLEROSIS AND SERUM HIGH SENSITIVITY C-REACTIVE PROTEIN LEVELS IN ELDERLY HYPERTENSIVE PATIENTS
Objectives
To investigate the correlation of carotid atherosclerosis and serum high sensitivity C-reactive protein levels in elderly hypertensive patients
...
A Preliminary Study of Wall Shear Stress in Carotid Artery Stenting
A Preliminary Study of Wall Shear Stress in Carotid Artery Stenting
Abstract
Objective: To characterize carotid wall shear stress (WSS)following carotid artery stenting (CAS) in patients with carotid stenosis.
Methods: Twenty-eight patient...
Stenting of ultraembolic hazardous carotid stenotic lesions using the technique of triple antiembolic protection
Stenting of ultraembolic hazardous carotid stenotic lesions using the technique of triple antiembolic protection
Objective ‒ to develop a technique of triple antiembolic protection with the simultaneous use of proximal antiembolic protection systems, distal antiembolic filters and two-layer m...
A Study on Position and Lumen Geometry at the Origin of External Carotid Artery in Human Adult Cadavers
A Study on Position and Lumen Geometry at the Origin of External Carotid Artery in Human Adult Cadavers
Background: External carotid artery is the predominant source of blood supply to the structures in the head and neck region. Morphological anomalies in the external and internal c...
Blood Flow Acoustics in Carotid Artery
Blood Flow Acoustics in Carotid Artery
This paper aims to identify and study the blood flow and acoustics characteristics of different degrees of stenosis in the carotid artery. Blood flow will produce acoustics, but th...

