Javascript must be enabled to continue!
Analyzing Droplet Size Distributions Inside a Self-Priming Venturi Scrubber for Filtered Containment Venting Systems
View through CrossRef
After the accident in the Fukushima Daiichi nuclear power plant, the interest of adding Filtered Containment Venting Systems (FCVS) on existing nuclear power plants to prevent radioactive releases to the environment during a severe accident has increased. Wet scrubbers are one possible design element which can be part of an FCVS system. The efficiency of this scrubber type is thereby depending, among others, on the thermal-hydraulic characteristics inside the scrubber. The flow structure is mainly established by the design of the gas inlet nozzle. The venturi geometry is one of the nozzle types that can be found in nowadays FCVS. It acts in two different steps on the removal process of the contaminants in the gas stream. Downstream the suction opening in the throat of the venturi, droplets are formed by atomization of the liquid film. The droplets are contributing to the capture of aerosols and volatile gases from the mixture coming from the containment. Studies state that the majority of the contaminants is scrubbed within this misty flow regime. At the top of the venturi, the gas stream is injected into the pool. The pressure drop at the nozzle exit leads to the formation of smaller bubbles, thus increasing the interfacial area concentration in the pool. In this work, the flow inside a full-scale venturi scrubber has been optically analyzed using shadowgraphy with a high-speed camera. The venturi nozzle was installed in the TRISTAN facility at PSI which was originally designed to investigate the flow dynamics of a tube rupture inside a full-length scale steam generator tube bundle. The data analysis was focused on evaluating the droplet size distribution and the Sauter mean diameter under different gas flow rates and operation modes. The scrubber was operated in two different ways, submerged and unsubmerged. The aim was to include the effect on the droplet sizes of using the nozzle in a submerged operation mode.
American Society of Mechanical Engineers
Title: Analyzing Droplet Size Distributions Inside a Self-Priming Venturi Scrubber for Filtered Containment Venting Systems
Description:
After the accident in the Fukushima Daiichi nuclear power plant, the interest of adding Filtered Containment Venting Systems (FCVS) on existing nuclear power plants to prevent radioactive releases to the environment during a severe accident has increased.
Wet scrubbers are one possible design element which can be part of an FCVS system.
The efficiency of this scrubber type is thereby depending, among others, on the thermal-hydraulic characteristics inside the scrubber.
The flow structure is mainly established by the design of the gas inlet nozzle.
The venturi geometry is one of the nozzle types that can be found in nowadays FCVS.
It acts in two different steps on the removal process of the contaminants in the gas stream.
Downstream the suction opening in the throat of the venturi, droplets are formed by atomization of the liquid film.
The droplets are contributing to the capture of aerosols and volatile gases from the mixture coming from the containment.
Studies state that the majority of the contaminants is scrubbed within this misty flow regime.
At the top of the venturi, the gas stream is injected into the pool.
The pressure drop at the nozzle exit leads to the formation of smaller bubbles, thus increasing the interfacial area concentration in the pool.
In this work, the flow inside a full-scale venturi scrubber has been optically analyzed using shadowgraphy with a high-speed camera.
The venturi nozzle was installed in the TRISTAN facility at PSI which was originally designed to investigate the flow dynamics of a tube rupture inside a full-length scale steam generator tube bundle.
The data analysis was focused on evaluating the droplet size distribution and the Sauter mean diameter under different gas flow rates and operation modes.
The scrubber was operated in two different ways, submerged and unsubmerged.
The aim was to include the effect on the droplet sizes of using the nozzle in a submerged operation mode.
Related Results
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
RANCANG BANGUN VENTURI SCRUBBER TERHADAP PENURUNAN EMISI JELAGA
RANCANG BANGUN VENTURI SCRUBBER TERHADAP PENURUNAN EMISI JELAGA
The industrial world and vehicles that currently exist make the pollution level increase. Often we see thick smoke rising out of the factory chimney, the thick smoke is a waste of ...
NGL Recovery - A New Concept for an Old Scrubber
NGL Recovery - A New Concept for an Old Scrubber
Abstract
Gas scrubbers are designed to protect process equipment, such as compressors, dehydration towers, pipelines and molecular sieves from liquids. The efficienc...
Study on Hydrogen Risk Venting Mitigation Measure of Small Steel Containment During Severe Accident
Study on Hydrogen Risk Venting Mitigation Measure of Small Steel Containment During Severe Accident
Abstract
The hydrogen risk in small steel containment is one of the most important safety problems of small modular reactor (SMR), effective measures need to be take...
Controlled production of double emulsion by microfluid technique
Controlled production of double emulsion by microfluid technique
All planned inertial confinement fusion (ICF) capsule targets except machined beryllium require plastic mandrels with tight requirements on which the ablator is built. In this pape...
Lattice Boltzmann simulation of droplet dynamics in a bifurcating micro-channel
Lattice Boltzmann simulation of droplet dynamics in a bifurcating micro-channel
The droplet dynamic in a bifurcating micro-channel, as one of the basic multiphase problems, is frequently encountered in the fields of science and engineering. Due to its great re...
Dust mitigation by a water droplet in between movable and modified wetting states surfaces
Dust mitigation by a water droplet in between movable and modified wetting states surfaces
AbstractA novel approach for mitigating environmental dust from hydrophobic surfaces using a water droplet is presented. A sessile droplet is sandwiched between two parallel plates...

