Percutaneous Balloon Mitral Commissurotomy During Pregnancy
View through CrossRef
Percutaneous balloon mitral commissurotomy was performed in 16 pregnant women aged 23 ±3 years (range, 16-39 years) who had severe mitral stenosis at pregnancies of mean gesta tional age 25 ±6 weeks. Ten patients were in New York Heart Association functional class III, and six patients were in functional class IV at the time of the procedure. All patients were symptomatic despite maximal medical therapy. The procedure was performed with the Inoue balloon. The mitral valve area increased from 0.9 ±0.3 to 1.8 ±0.3 cm
2
(p < 0.05). The mitral valve pressure gradient decreased from 23 ±7 to 6 ±3 mm Hg (p < 0.05). The left atrial pressure decreased from 28 ±8 to 10 ±4 mm Hg (p < 0.05). The pulmonary artery pressure decreased from 59 ±18 to 33 ± 12 mm Hg (p<0.05). Fourteen patients continued their pregnancies to mean gestational age 37 ±2 weeks; all infants were healthy. Two patients had premature deliv eries more than 1 month after the procedure due to obstetrical reasons. The two newborns died at day 2 of respiratory distress. Eleven women had vaginal deliveries and five had cesarean sections. All clinically improved to New York Heart Association functional class I or II. Excessive blood loss from the femoral puncture site that required transfusion occurred in one patient. Mitral regurgitation increased one degree in four patients, from 0 to 1 +. Patients were observed until delivery. None had restenosis. The degree of mitral regurgitation remained unchanged. Percutaneous balloon mitral commissurotomy can be performed safely during pregnancy. It will effectively improve hemodynamics and symptoms in pregnant patients who have severe mitral stenosis and persistent congestive heart failure symptoms despite conventional medical treatment. There are no immediate detrimental effects of radiation on the fetus. Risks are lower than previously reported when surgical commissurotomy was performed.
Title: Percutaneous Balloon Mitral Commissurotomy During Pregnancy
Description:
Percutaneous balloon mitral commissurotomy was performed in 16 pregnant women aged 23 ±3 years (range, 16-39 years) who had severe mitral stenosis at pregnancies of mean gesta tional age 25 ±6 weeks.
Ten patients were in New York Heart Association functional class III, and six patients were in functional class IV at the time of the procedure.
All patients were symptomatic despite maximal medical therapy.
The procedure was performed with the Inoue balloon.
The mitral valve area increased from 0.
9 ±0.
3 to 1.
8 ±0.
3 cm
2
(p < 0.
05).
The mitral valve pressure gradient decreased from 23 ±7 to 6 ±3 mm Hg (p < 0.
05).
The left atrial pressure decreased from 28 ±8 to 10 ±4 mm Hg (p < 0.
05).
The pulmonary artery pressure decreased from 59 ±18 to 33 ± 12 mm Hg (p<0.
05).
Fourteen patients continued their pregnancies to mean gestational age 37 ±2 weeks; all infants were healthy.
Two patients had premature deliv eries more than 1 month after the procedure due to obstetrical reasons.
The two newborns died at day 2 of respiratory distress.
Eleven women had vaginal deliveries and five had cesarean sections.
All clinically improved to New York Heart Association functional class I or II.
Excessive blood loss from the femoral puncture site that required transfusion occurred in one patient.
Mitral regurgitation increased one degree in four patients, from 0 to 1 +.
Patients were observed until delivery.
None had restenosis.
The degree of mitral regurgitation remained unchanged.
Percutaneous balloon mitral commissurotomy can be performed safely during pregnancy.
It will effectively improve hemodynamics and symptoms in pregnant patients who have severe mitral stenosis and persistent congestive heart failure symptoms despite conventional medical treatment.
There are no immediate detrimental effects of radiation on the fetus.
Risks are lower than previously reported when surgical commissurotomy was performed.
Related Results
Immediate maternal and fetal outcome following percutaneous mitral valve balloon commissurotomy: a 6-year single-center experience from sub-Saharan Africa
Immediate maternal and fetal outcome following percutaneous mitral valve balloon commissurotomy: a 6-year single-center experience from sub-Saharan Africa
AbstractBackground:Mitral stenosis is the most common valvular heart disease during pregnancy. When severe, it leads to significant maternal and fetal morbidity and mortality. Perc...
Playing Pregnancy: The Ludification and Gamification of Expectant Motherhood in Smartphone Apps
Playing Pregnancy: The Ludification and Gamification of Expectant Motherhood in Smartphone Apps
IntroductionLike other forms of embodiment, pregnancy has increasingly become subject to representation and interpretation via digital technologies. Pregnancy and the unborn entity...
Prior surgical mitral commissurotomy and echocardiographic score influence in mitral balloon valvuloplasty. Immediate post procedure results
Prior surgical mitral commissurotomy and echocardiographic score influence in mitral balloon valvuloplasty. Immediate post procedure results
Abstract
Introduction
Percutaneous mitral balloon valvuloplasty is effective in mitral stenosis. Objectives: to evaluate prior m...
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Objective: To evaluate accuracy of mitral leaflet separation index for the determination of mitral stenosis severity in patients with rheumatic mitral stenosis.
Method: The prospec...
Mid-term results of percutaneous transmitral commissurotomy (PTMC) in central iran
Mid-term results of percutaneous transmitral commissurotomy (PTMC) in central iran
Objectives: Percutaneous Trans-Mitral Commissurotomy (PTMC) is an effective non-surgical treatment in patients with severe rheumatic mitral valve stenosis. This study aimed to eval...
FREQUENCY OF ACUTE MITRAL REGURGITATION IN POST PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY PATIENTS WITH SEVERE MITRAL STENOSIS
FREQUENCY OF ACUTE MITRAL REGURGITATION IN POST PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY PATIENTS WITH SEVERE MITRAL STENOSIS
Objectives: To determine the frequency of Acute Mitral Regurgitation in Post Percutaneous Transvenous Mitral Commissurotomy (PTMC) patients with severe mitral stenosis (MS).
Method...
Diagnostic accuracy of total echo score and total commissural morphology score for the prediction of outcome after percutaneous transvenous mitral commissurotomy (PTMC)
Diagnostic accuracy of total echo score and total commissural morphology score for the prediction of outcome after percutaneous transvenous mitral commissurotomy (PTMC)
INTRODUCTION: Percutaneous transvenous mitral commissurotomy (PTMC), a procedure that treats certain individuals with mitral stenosis, is now frequently used as an alternative to c...
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...