Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Electrolyzed Salt Solutions Used against Major Postharvest Diseases of Fresh Fruit and Vegetables

View through CrossRef
Alternative means of control are becoming increasingly relevant to the improvement of safety and the reduction of postharvest losses and waste of fruit and vegetables, especially in view of the application of the EU Greed Deal. A previous study from our research group that focused on the electrolysis process of water and was conducted using NaCl and NaHCO3 as electrolytes proved to efficiently reduce pathogen inoculum in packinghouse washing water. In the present study, we examined the effect of the electrolyzed salt solutions (eNaCl and eNaHCO3) produced in the same experimental conditions previously reported to be used as postharvest treatments during handling and commercialization, and/or at the consumer’s site. We tested the electrolyzed solutions, obtained in the presence or absence of the salts, against five relevant fungal pathogens in terms of conidia viability, and on various hosts in terms of rot incidence/severity. Chemical parameters of electrolyzed and non-electrolyzed solutions were also assessed. Although a different susceptibility to treatments was observed among pathogens, electrolyzed sodium chloride (eNaCl) was the most efficient treatment for preventing spore germination, as well as for minimizing fruit rot. However, a consistent control of fungal viability and consequent rot was also achieved using electrolyzed tap water (eW). The eNaHCO3, although less efficient on fungal viability, provided a significant effect against fruit rot. The investigated electrolyzed solutions seem promising for reducing the waste of fresh fruit and vegetables.
Title: Electrolyzed Salt Solutions Used against Major Postharvest Diseases of Fresh Fruit and Vegetables
Description:
Alternative means of control are becoming increasingly relevant to the improvement of safety and the reduction of postharvest losses and waste of fruit and vegetables, especially in view of the application of the EU Greed Deal.
A previous study from our research group that focused on the electrolysis process of water and was conducted using NaCl and NaHCO3 as electrolytes proved to efficiently reduce pathogen inoculum in packinghouse washing water.
In the present study, we examined the effect of the electrolyzed salt solutions (eNaCl and eNaHCO3) produced in the same experimental conditions previously reported to be used as postharvest treatments during handling and commercialization, and/or at the consumer’s site.
We tested the electrolyzed solutions, obtained in the presence or absence of the salts, against five relevant fungal pathogens in terms of conidia viability, and on various hosts in terms of rot incidence/severity.
Chemical parameters of electrolyzed and non-electrolyzed solutions were also assessed.
Although a different susceptibility to treatments was observed among pathogens, electrolyzed sodium chloride (eNaCl) was the most efficient treatment for preventing spore germination, as well as for minimizing fruit rot.
However, a consistent control of fungal viability and consequent rot was also achieved using electrolyzed tap water (eW).
The eNaHCO3, although less efficient on fungal viability, provided a significant effect against fruit rot.
The investigated electrolyzed solutions seem promising for reducing the waste of fresh fruit and vegetables.

Related Results

Endoscope Disinfection with Acid Electrolyzed Water
Endoscope Disinfection with Acid Electrolyzed Water
Abstract:Reports of endoscope‐mediated infectious diseases have been increasing. In order to investigate the usefulness of acid electrolyzed water for endoscope disinfection, a tes...
British Food Journal Volume 35 Issue 5 1933
British Food Journal Volume 35 Issue 5 1933
The Fruit Control Act, 1924, is an important one as it provides for the establishment of a Fruit Control Board, and is described as an “Act to make Provision for Control of the Fru...
Electrolyzed Water for Selective Etching of Metals
Electrolyzed Water for Selective Etching of Metals
Electrolyzed water (EW) is a promising tool for wet cleaning of semiconductor devices. At the anode, hydroxyl radicals exhibiting a very high oxidation reduction potential (ORP) ar...
Quality Improvement of Chicken Meat Treated with Neutral Electrolyzed Water
Quality Improvement of Chicken Meat Treated with Neutral Electrolyzed Water
Background: Chicken meat during processing may be exposed to bacterial contamination through several different ways. Electrolyzed water, as a new sanitizer, has gained popularity i...
Antioxidant contents of pre‐packed fresh‐cut versus whole fruit and vegetables
Antioxidant contents of pre‐packed fresh‐cut versus whole fruit and vegetables
PurposeThe purpose of this paper is to evaluate the difference in antioxidant contents of pre‐packed fresh‐cut and whole fruit and vegetables as sold in the market.Design/methodolo...
Deformation of Allochthonous Salt and Evolution of Related Salt-Structural Systems, Eastern Louisiana Gulf Coast
Deformation of Allochthonous Salt and Evolution of Related Salt-Structural Systems, Eastern Louisiana Gulf Coast
Abstract Salt tectonics in the northern Gulf of Mexico involves both vertical diapirism and lateral silling or flow of salt into wings and tablets (sheets). Combi...
Postharvest Plant Pathology
Postharvest Plant Pathology
The purpose of the book 'Postharvest Plant Pathology' is to provide its readers recent developments and uated comprehensive information on postharvest pathogens & diseases of m...

Back to Top