Javascript must be enabled to continue!
Performance Comparison Of Shunt Rf Mems Switches
View through CrossRef
This is an attempt to compare three different shunt configured RF MEMS switches which offers a choice for applications in satellite and antennas. Advanced RF communication domain demands for design and modeling of RF MEMS switch which provides extremely reduced pull-in voltage, better isolation, low insertion loss, and with greater reliability. The proposed work manages with comparison of design modeling and performance of three different shunt configured RF MEMS switches. The proposed shunt configured RF MEMS switches are designed with different dimensions with different meandering techniques with perforations on beam structure helps in reducing the amount of voltage required for actuation of switch which is known as pull-in voltage. Comparative study of three different RF MEMS switches which involves in conducting electromechanical analysis are carried out using COMSOL multi physics tool and electromagnetic analysis are carried out using HFSS tool. Moreover the comparative study involves in comparing the values of pull-in voltage, switching time and capacitance, stress, insertion loss, return loss and isolation of three different RF MEMS switches. Proposed first switch model derives pull-in voltage of 16.9v with the switching time of 1.2µs, isolation of 47.70 dB at 5GHz and insertion loss of 0.0865 dB and return loss of 41.55 dB. Proposed second switch model derives pull-in voltage of 18.5v with the switching time of 2.5µs, isolation of 37.20 dB at 8GHz and insertion loss of 0.1177 dB and return loss of 38.60 dB. Proposed third switch model delivers pull-in voltage of 18.75v with the switching time of 2.56µs, isolation of 44.1552 dB at 8GHz and insertion loss of 0.0985 dB and return loss of 42.1004 dB.
Title: Performance Comparison Of Shunt Rf Mems Switches
Description:
This is an attempt to compare three different shunt configured RF MEMS switches which offers a choice for applications in satellite and antennas.
Advanced RF communication domain demands for design and modeling of RF MEMS switch which provides extremely reduced pull-in voltage, better isolation, low insertion loss, and with greater reliability.
The proposed work manages with comparison of design modeling and performance of three different shunt configured RF MEMS switches.
The proposed shunt configured RF MEMS switches are designed with different dimensions with different meandering techniques with perforations on beam structure helps in reducing the amount of voltage required for actuation of switch which is known as pull-in voltage.
Comparative study of three different RF MEMS switches which involves in conducting electromechanical analysis are carried out using COMSOL multi physics tool and electromagnetic analysis are carried out using HFSS tool.
Moreover the comparative study involves in comparing the values of pull-in voltage, switching time and capacitance, stress, insertion loss, return loss and isolation of three different RF MEMS switches.
Proposed first switch model derives pull-in voltage of 16.
9v with the switching time of 1.
2µs, isolation of 47.
70 dB at 5GHz and insertion loss of 0.
0865 dB and return loss of 41.
55 dB.
Proposed second switch model derives pull-in voltage of 18.
5v with the switching time of 2.
5µs, isolation of 37.
20 dB at 8GHz and insertion loss of 0.
1177 dB and return loss of 38.
60 dB.
Proposed third switch model delivers pull-in voltage of 18.
75v with the switching time of 2.
56µs, isolation of 44.
1552 dB at 8GHz and insertion loss of 0.
0985 dB and return loss of 42.
1004 dB.
Related Results
High Isolation X-Band RF MEMS Shunt Switches on Groove Etched Substrates
High Isolation X-Band RF MEMS Shunt Switches on Groove Etched Substrates
Developments in RF MEMS switches have demonstrated great potential at low-loss microwave application. MEMS shunt switches have a few advantages compared to the FET or p-i-n diode c...
Uncommon complications of ventriculoperitoneal shunt surgery: review of four cases and literature review
Uncommon complications of ventriculoperitoneal shunt surgery: review of four cases and literature review
Abstract
Background
Ventriculoperitoneal shunt is one of the most popular cerebrospinal fluid diversion procedures worldwide. Complications are common, but uncommon complications a...
(Invited) A 1-mG MEMS Sensor
(Invited) A 1-mG MEMS Sensor
MEMS (microelectromechanical systems) technology has contributed substantially to the miniaturization of inertial sensors, such as accelerometers and gyroscopes [1]. Nowadays, MEMS...
Role of Antibiotic-Impregnated Shunts in Preventing Shunt-Related Infections: Long-Term Outcomes in Pediatric Patients
Role of Antibiotic-Impregnated Shunts in Preventing Shunt-Related Infections: Long-Term Outcomes in Pediatric Patients
Background: The most common treatment for pediatric hydrocephalus is the implantation of a ventriculoperitoneal (VP) shunt. Shunt-related infections, however, continue to be one of...
Reconfigurable band pass filter based on DMTL structure
Reconfigurable band pass filter based on DMTL structure
This paper presents the design and optimization of CPW (coplanar
waveguide) based tunable band pass filter by using RF MEMS capacitive
switches and distributed MEMS transmission li...
Assessing the Effectiveness of Neuro-Endoscopic Procedures in the Treatment of Hydrocephalus
Assessing the Effectiveness of Neuro-Endoscopic Procedures in the Treatment of Hydrocephalus
Objective: The purpose of this systematic study is to assess the mortality results of early vs. delayed VP shunt implantation for hydrocephalus caused by myelomeningocele and exami...
Cerebrospinal Fluid Shunt Complications after Urological Procedures in Children with Myelodysplasia
Cerebrospinal Fluid Shunt Complications after Urological Procedures in Children with Myelodysplasia
ABSTRACT
OBJECTIVE
Invasive urological procedures, commonly performed on patients with myelodysplasia, may contribute to the occ...
Indications of ventriculoperitoneal shunt: a prospective study
Indications of ventriculoperitoneal shunt: a prospective study
Background: Shunts have been used to drain the Cerebrospinal fluid into practically every body cavity, organ system and tissue spaces. Scraff has critically reviewed the efficacy o...