An Experimental Investigation and Computer Modeling of Direct Tension Pullout Test of Reinforced Concrete Cylinder

View through CrossRef
Executing the obligation of strengthened concrete is essential in investigating load exchanges from concrete to the inner reinforcing bar. The bond–displacement conduct and extreme pullout quality for pullout samples are essential information related to the durability of RC structures. The slip in the interface is basically due to a contrast in stresses between concrete and reinforcement. This distinction brings about the start of the split in encompassing concrete. This study examined the simple pullout solid 3D cylinder model strengthened by a reinforced steel bar, considered a line element for bond–slip conduct. The non-linear finite element model utilizing ANSYS software was established to concentrate on the concrete and steel reinforcement bond. Material nonlinearity because of cracking, crushing of concrete, and the steel reinforcing bar’s yielding were investigated. Test results showed that: a prediction model for early-age bond stress–slip relationship between steel bars and concrete was proposed based on modeling, which showed good agreement with test results. The precision of this model is explored by contrasting the finite element numerical analysis and that anticipated from test consequences of pullout examples. Immense homogeneity between the model and test results was found. This study could provide more accurate bond properties for structural analysis and design.
Title: An Experimental Investigation and Computer Modeling of Direct Tension Pullout Test of Reinforced Concrete Cylinder
Description:
Executing the obligation of strengthened concrete is essential in investigating load exchanges from concrete to the inner reinforcing bar.
The bond–displacement conduct and extreme pullout quality for pullout samples are essential information related to the durability of RC structures.
The slip in the interface is basically due to a contrast in stresses between concrete and reinforcement.
This distinction brings about the start of the split in encompassing concrete.
This study examined the simple pullout solid 3D cylinder model strengthened by a reinforced steel bar, considered a line element for bond–slip conduct.
The non-linear finite element model utilizing ANSYS software was established to concentrate on the concrete and steel reinforcement bond.
Material nonlinearity because of cracking, crushing of concrete, and the steel reinforcing bar’s yielding were investigated.
Test results showed that: a prediction model for early-age bond stress–slip relationship between steel bars and concrete was proposed based on modeling, which showed good agreement with test results.
The precision of this model is explored by contrasting the finite element numerical analysis and that anticipated from test consequences of pullout examples.
Immense homogeneity between the model and test results was found.
This study could provide more accurate bond properties for structural analysis and design.

Related Results

Experimental study on the pullout characteristics of toothed warp knitted geogrid in different sand fillers
Experimental study on the pullout characteristics of toothed warp knitted geogrid in different sand fillers
In order to investigate the pullout characteristics of a toothed geogrid, a commercialized warp-knitted geogrid was combined with rigid angle aluminum to form a qualified toothed g...
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
VOLUMETRIC RIGIDITY OF HYDRAULIC SYSTEMS
VOLUMETRIC RIGIDITY OF HYDRAULIC SYSTEMS
A hydraulic drive is a set of interacting hydraulic devices that is designed to be ghosted by means of a working fluid under pressure. The main element in hydraulic drives most mac...
Steel fiber concrete. Constructions. Terminology
Steel fiber concrete. Constructions. Terminology
The article discusses the terms and definitions that are increasingly appearing in the open press and on the Internet, confusing well-established concepts. The purpose of consideri...
Model for chloride ingress into reinforced concrete structure under load and marine environment
Model for chloride ingress into reinforced concrete structure under load and marine environment
The durability of reinforced concrete structures is very important and becomes serious problems in construction technology nowadays. Many factors, such as concrete proportion, serv...
Performance Evaluation of Nonwoven Geotextiles in Soil-Fabric Interaction
Performance Evaluation of Nonwoven Geotextiles in Soil-Fabric Interaction
A laboratory research program was undertaken to determine the influence of fabric mass and normal pressure on the stress-strain characteristics of a geotextile-soil inter face. Pul...
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Abstract The research aims to study the behaviour of concrete columns reinforced with fibreglass as bars exposed to seawater. Firstly, hardened concrete properties a...
Effects of concrete cover thickness and concrete strength on temperature transfer in high temperature exposed FRP reinforced concrete
Effects of concrete cover thickness and concrete strength on temperature transfer in high temperature exposed FRP reinforced concrete
While Fibre-Reinforced Plastics are lightweight, show a high tensile strength, and have no issue with corrosion, they are unfortunately brittle and perform poorly against temperatu...