Javascript must be enabled to continue!
An induced annealing technique for SiPMs neutron radiation damage
View through CrossRef
Abstract
The use of Silicon Photo-Multipliers (SiPMs) has become popular in the
design of High Energy Physics experimental apparatus with a growing
interest for their application in detector area where a significant
amount of non-ionising dose is delivered. For these devices, the main
effect caused by the neutron fluence is a linear increase of the leakage
current. In this paper, we present a technique that provides a
partial recovery of the neutron damage on SiPMs by means of an
Electrical Induced Annealing. Tests were performed, at the temperature of 20°C, on a sample of
three SiPM arrays (2×3) of 6 mm2 cells with 50 μm
pixel sizes: two from Hamamatsu and one from
SensL. These SiPMs have been exposed to neutrons generated by the Elbe Positron Source facility (Dresden),
up to a total fluence of 8 × 1011 n1
MeV-eq/cm2. Our techniques allowed to reduced the leakage
current of a factor ranging between 15-20 depending on the overbias
used and the SiPM vendor. Because, during the process the
SiPM current can reach O(100 mA), the sensors need to be operated in a condition that
provides thermal dissipation. Indeed, caution must be used when applying this kind of
procedures on the SiPMs, because it may damage permanently the devices themself.
Title: An induced annealing technique for SiPMs neutron radiation damage
Description:
Abstract
The use of Silicon Photo-Multipliers (SiPMs) has become popular in the
design of High Energy Physics experimental apparatus with a growing
interest for their application in detector area where a significant
amount of non-ionising dose is delivered.
For these devices, the main
effect caused by the neutron fluence is a linear increase of the leakage
current.
In this paper, we present a technique that provides a
partial recovery of the neutron damage on SiPMs by means of an
Electrical Induced Annealing.
Tests were performed, at the temperature of 20°C, on a sample of
three SiPM arrays (2×3) of 6 mm2 cells with 50 μm
pixel sizes: two from Hamamatsu and one from
SensL.
These SiPMs have been exposed to neutrons generated by the Elbe Positron Source facility (Dresden),
up to a total fluence of 8 × 1011 n1
MeV-eq/cm2.
Our techniques allowed to reduced the leakage
current of a factor ranging between 15-20 depending on the overbias
used and the SiPM vendor.
Because, during the process the
SiPM current can reach O(100 mA), the sensors need to be operated in a condition that
provides thermal dissipation.
Indeed, caution must be used when applying this kind of
procedures on the SiPMs, because it may damage permanently the devices themself.
Related Results
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Abstract
Introduction
Cancer is one of the major medical problems threatening human health. Breast cancer ...
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract
The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Proton Irradiation and Thermal Restoration of SiPMs for LEO Missions
Proton Irradiation and Thermal Restoration of SiPMs for LEO Missions
Silicon Photomultipliers (SiPMs) are optical sensors widely used in space applications due to their high photon detection efficiency, low power consumption, and robustness. However...
Proton Irradiation and Thermal Recovery of SiPMs for LEO Missions
Proton Irradiation and Thermal Recovery of SiPMs for LEO Missions
Silicon Photomultipliers (SiPMs) are optical sensors widely used in space applications due to their high photon detection efficiency, low power consumption, and robustness. However...
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
In our previous research which has published in 62th SPWLA symposium, a numerical simulation method was proposed which about the double particle detector CLYC (Cs2LiYCl6:CE) to get...

