Javascript must be enabled to continue!
Numerical Simulation on Temperature and Moisture Fields Around Cooling Towers Used in Mine Ventilation System
View through CrossRef
For heat rejection, small air-cooling towers are widely used in mine ventilation systems. However, the thermal efficiency of the cooling towers can be significantly affected by their geometrical arrangement and crosswind conditions. In certain ambient conditions, heated air coming from an exit of one tower can flow to intakes of other towers, which leads to a reduction in the thermal efficiency of the entire ventilation system. The aim of this study was to investigate the influence of crosswind speed and tower spacing on the temperature and moisture content of intakes of cooling towers. For this purpose, a three-dimensional CFD model of the non-isothermal turbulent flow of moist air around cooling towers is proposed. The model is based on the Reynolds-averaged Navier–Stokes equations with a standard turbulence model which are supplemented by heat transfer and moisture transport equations. The investigation of the effects of the crosswind speed and the tower spacing was carried out for two cooling towers by multiparametric numerical simulation using the CFD model. It was shown that the upstream tower protects the downstream one from the effect of the crosswind. The increase in the crosswind speed causes a rise in temperature and moisture content at the intakes of the downstream tower. The increase in the tower spacing, in general, contributes to a decrease in air temperature at the intakes of the downstream tower. However, at low crosswind speed, the heat transfer at the intakes can rise with the tower spacing due to a reduction in the protection possibilities of the upstream tower. Results of the numerical simulation of airflow around three cooling towers indicated that the increase in the number of cooling towers contributes to a rise in temperature and moisture content at the intakes.
Title: Numerical Simulation on Temperature and Moisture Fields Around Cooling Towers Used in Mine Ventilation System
Description:
For heat rejection, small air-cooling towers are widely used in mine ventilation systems.
However, the thermal efficiency of the cooling towers can be significantly affected by their geometrical arrangement and crosswind conditions.
In certain ambient conditions, heated air coming from an exit of one tower can flow to intakes of other towers, which leads to a reduction in the thermal efficiency of the entire ventilation system.
The aim of this study was to investigate the influence of crosswind speed and tower spacing on the temperature and moisture content of intakes of cooling towers.
For this purpose, a three-dimensional CFD model of the non-isothermal turbulent flow of moist air around cooling towers is proposed.
The model is based on the Reynolds-averaged Navier–Stokes equations with a standard turbulence model which are supplemented by heat transfer and moisture transport equations.
The investigation of the effects of the crosswind speed and the tower spacing was carried out for two cooling towers by multiparametric numerical simulation using the CFD model.
It was shown that the upstream tower protects the downstream one from the effect of the crosswind.
The increase in the crosswind speed causes a rise in temperature and moisture content at the intakes of the downstream tower.
The increase in the tower spacing, in general, contributes to a decrease in air temperature at the intakes of the downstream tower.
However, at low crosswind speed, the heat transfer at the intakes can rise with the tower spacing due to a reduction in the protection possibilities of the upstream tower.
Results of the numerical simulation of airflow around three cooling towers indicated that the increase in the number of cooling towers contributes to a rise in temperature and moisture content at the intakes.
Related Results
British Food Journal Volume 45 Issue 1 1943
British Food Journal Volume 45 Issue 1 1943
The complex cellular structure and chemical nature of fruit and vegetable tissues retard evaporation so that under no conditions of temperature and humidity does the rate of evapor...
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Aims.To determine the practicality and safety of head cooling with mild or minimal systemic hypothermia in term neonates with moderate to severe hypoxic-ischemic encephalopathy.Met...
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Abstract
In Large Gas Turbines, turbine components in particular blades and vanes operate at significantly high temperatures. As a result, cooling of these component...
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
CT ventilation imaging is an exciting functional imaging modality that combines four‐dimensional computed tomography (4DCT) and deformable image registration (DIR) to provide exqui...
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Modern gas turbine units (GTUs) operate at extremely high temperatures, with mainstream gas temperatures reaching 1700–1750 °C in transport and military applications, while heat-re...
Study on Flow Coefficient of Film Cooling Hole in Combustor
Study on Flow Coefficient of Film Cooling Hole in Combustor
The cooling hole is an important structural component of gas turbine combustion chamber. A part of air enters the combustion chamber through the cooling hole through the external p...
Structural Retrofit Analysis of Converting a Conventional Wet Cooling Tower to a High-Level Water Collecting Cooling Tower
Structural Retrofit Analysis of Converting a Conventional Wet Cooling Tower to a High-Level Water Collecting Cooling Tower
Conventional natural ventilation cooling towers are critical structures in coal-fired power plants. As the unit capacity of coal-fired power plants continues to increase, the circu...
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Abstract