Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

PERFORMANCE EVALUATION OF SOLAR PHOTOVOLTAIC PANEL MOUNTED ON SLOPED CORRUGATED METAL SHEET ROOF IN KANO STATE NORTHWEST NIGERIA

View through CrossRef
Installation of solar photovoltaic system on roof has advantages of proper utilization of space, help in avoiding shading effects and reduction of dust accumulation on the panels. However, electrical efficiency and lifespan of solar photovoltaic panel tends to decrease due to the increase in surface temperature above the operation temperature of the panels due to its contact with the roofing sheets. The performance of solar photovoltaic panels was experimentally investigated on   corrugated metal sheet (CMS) roof at four different heights (0, 100, 200, and 300mm). Four polycrystalline silicon photovoltaic panels of 10 watts each were selected from the same manufacturer. The temperatures on the roof and on the photovoltaic panels’ surfaces were measured at different solar hours. Also, the outputs of the solar panels together with the irradiance available were measured at same hours using an electronic data logger and imported to an Excel software.  Irradiance variation, gap between roof and photovoltaic panels, and heating effect on panels were found to be the parameters affecting the photovoltaic system’s performance. The highest temperature attained by the photovoltaic panel is when it was directly mounted on the roof as 76.5°C while the other photovoltaic panels mounted at a gap height of 100mm, 200mm and 300mm attained the highest temperature of 71.8oC, 69,6oC and 68.0oC respectively. The panels’ extra heat was originating from CMS roof vicinity. Output powers from the panels were unequal throughout the experiment whilst exhibited similar behavior. The panels’ temperature dropped... 
Title: PERFORMANCE EVALUATION OF SOLAR PHOTOVOLTAIC PANEL MOUNTED ON SLOPED CORRUGATED METAL SHEET ROOF IN KANO STATE NORTHWEST NIGERIA
Description:
Installation of solar photovoltaic system on roof has advantages of proper utilization of space, help in avoiding shading effects and reduction of dust accumulation on the panels.
However, electrical efficiency and lifespan of solar photovoltaic panel tends to decrease due to the increase in surface temperature above the operation temperature of the panels due to its contact with the roofing sheets.
The performance of solar photovoltaic panels was experimentally investigated on   corrugated metal sheet (CMS) roof at four different heights (0, 100, 200, and 300mm).
Four polycrystalline silicon photovoltaic panels of 10 watts each were selected from the same manufacturer.
The temperatures on the roof and on the photovoltaic panels’ surfaces were measured at different solar hours.
Also, the outputs of the solar panels together with the irradiance available were measured at same hours using an electronic data logger and imported to an Excel software.
  Irradiance variation, gap between roof and photovoltaic panels, and heating effect on panels were found to be the parameters affecting the photovoltaic system’s performance.
The highest temperature attained by the photovoltaic panel is when it was directly mounted on the roof as 76.
5°C while the other photovoltaic panels mounted at a gap height of 100mm, 200mm and 300mm attained the highest temperature of 71.
8oC, 69,6oC and 68.
0oC respectively.
The panels’ extra heat was originating from CMS roof vicinity.
Output powers from the panels were unequal throughout the experiment whilst exhibited similar behavior.
The panels’ temperature dropped.
 .

Related Results

The Impact of Roof Material Profile and Pigmentation on the Performance of Photovoltaic Modules
The Impact of Roof Material Profile and Pigmentation on the Performance of Photovoltaic Modules
This study combines simulations and experiments to study the heat interactions between various types of roofs and the photovoltaic (PV) modules installed on them. Specifically, the...
Changes in Tiled Roof Landscape of Jeseoksa Temple Site in Iksan
Changes in Tiled Roof Landscape of Jeseoksa Temple Site in Iksan
This study focused on the fact that the main role of roof tiles is the finishing material of the roof, and looked at the shape of the roof that functions as a series of components ...
RANCANG BANGUN SISTEM GERAK PANEL SURYA BERBASIS ARDUINO UNO
RANCANG BANGUN SISTEM GERAK PANEL SURYA BERBASIS ARDUINO UNO
Panel Surya (Panel Photovoltaik) adalah suatu panel yang terdiri dari kumpulan sel surya berfungsi merubah energi cahaya menjadi energi listrik dengan memanfaatkan efek photovoltai...
Solar Trackers Using Six-Bar Linkages
Solar Trackers Using Six-Bar Linkages
Abstract A solar panel faces the sun or has the solar ray normal to its face to enhance power reaping. A fixed solar panel can only meet this condition at one moment...
Roof truss systems under blast loads
Roof truss systems under blast loads
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] Designing roof systems for blast loading is quite complex. Many uncertainties still exist in this vital resea...
Solar wind interaction with comet 67P around perihelion
Solar wind interaction with comet 67P around perihelion
AbstractNear perihelion, when comet 67P was most active, the Rosetta spacecraft resided inside the comet induced magnetosphere. The solar wind magnetic field was still present, but...

Back to Top