Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

ANALISIS EFISIENSI TURBIN UAP UNIT 1 DI PT. PJB UBJOM PLTU PULANG PISAU KALIMANTAN TENGAH

View through CrossRef
This study aims to determine the performance of steam turbine PT. PJB UBJOM PLTU Pulang Pisau Kalimantan Tengah the results of data obtained during each performance test in commisioning 2016 and 2018. This research data is taken from the control room of PT. PJB UBJOM PLTU Pulang Pisau, variable data obtained in the form of load, main inlet steam temperature, main inlet steam pressure, HP heater feed outlet temperature, HP heater feed outlet pressure, main steam flow, and turbine by pass flow. The data is processed to get the turbine heat rate and the efficiency per time of each performance test and then averaging the data results over time, then comparing the turbine heat rate and the average efficiency of each performance test. The calculation of turbine heat rate using heat & mass balance method, turbine efficiency is obtained by comparing the energy of 1 kW with turbine heat rate and multiplying 100%. The result of the average heat turbine calculation per performance test highest ie September 2016 is 3,51and Juli 2018 is 3,27. The average value of turbine efficiency in September 2016 was 29,03% and Juli 2018 was 33,84. Turbine power plant performance of PT. PJB UBJOM PLTU Pulang Pisau increase from 2016 to 2018 by 4,81 %.Keywords:Turbin Heat Rate, Efisiensi Turbin
Center for Journal Management and Publication, Lambung Mangkurat University
Title: ANALISIS EFISIENSI TURBIN UAP UNIT 1 DI PT. PJB UBJOM PLTU PULANG PISAU KALIMANTAN TENGAH
Description:
This study aims to determine the performance of steam turbine PT.
PJB UBJOM PLTU Pulang Pisau Kalimantan Tengah the results of data obtained during each performance test in commisioning 2016 and 2018.
This research data is taken from the control room of PT.
PJB UBJOM PLTU Pulang Pisau, variable data obtained in the form of load, main inlet steam temperature, main inlet steam pressure, HP heater feed outlet temperature, HP heater feed outlet pressure, main steam flow, and turbine by pass flow.
The data is processed to get the turbine heat rate and the efficiency per time of each performance test and then averaging the data results over time, then comparing the turbine heat rate and the average efficiency of each performance test.
The calculation of turbine heat rate using heat & mass balance method, turbine efficiency is obtained by comparing the energy of 1 kW with turbine heat rate and multiplying 100%.
The result of the average heat turbine calculation per performance test highest ie September 2016 is 3,51and Juli 2018 is 3,27.
The average value of turbine efficiency in September 2016 was 29,03% and Juli 2018 was 33,84.
Turbine power plant performance of PT.
PJB UBJOM PLTU Pulang Pisau increase from 2016 to 2018 by 4,81 %.
Keywords:Turbin Heat Rate, Efisiensi Turbin.

Related Results

ASSOCIATION OF THE SERUM LEVELS OF C-REACTIVE PROTEIN WITH ITS GENE POLYMORPHISMS AND ACUTE CORONARY SYNDROME
ASSOCIATION OF THE SERUM LEVELS OF C-REACTIVE PROTEIN WITH ITS GENE POLYMORPHISMS AND ACUTE CORONARY SYNDROME
Objectives To investigate the association of the serum levels of CRP with its gene polymorphisms and the risk of ACS in Chinese Han population in Sunan region. ...
Pengaruh Deposisi dan Erosi Pada Sudu-Sudu Terhadap Kinerja Turbin PLT Panas Bumi Patuha
Pengaruh Deposisi dan Erosi Pada Sudu-Sudu Terhadap Kinerja Turbin PLT Panas Bumi Patuha
Turbin uap seringkali mengalami masalah deposisi dan erosi pada bagian sudu yang dapat menurunkan kinerja turbin uap. Oleh karena itu, diperlukan analisis deposisi dan erosi pada s...
PENGUJIAN TURBIN ANGIN DARRIEUS DI PANTAI MATEMATIK DELI SERDANG DENGAN VARIASI JUMLAH BLADE
PENGUJIAN TURBIN ANGIN DARRIEUS DI PANTAI MATEMATIK DELI SERDANG DENGAN VARIASI JUMLAH BLADE
Salah satu faktor yang mempengaruhi efisiensi energi yang dibangkitkan adalah jumlah bilah angin. Penelitian ini dapat memberikan reverensi kepada masyarakat secara umum dan khusus...
Perancangan turbin uap untuk siklus gabungan
Perancangan turbin uap untuk siklus gabungan
Turbin gas beroperasi pada temperatur yang tinggi, sekitar 1100 — 1650”C. Temperatur gas-gas hasil pembakaran pada turbin gas biasanya masih cukup tinggi, sehingga masih mengandung...
Hubungan Status Gizi dan Anemia dengan Penyakit Jantung Bawaan pada Anak
Hubungan Status Gizi dan Anemia dengan Penyakit Jantung Bawaan pada Anak
Latar belakang. Penyakit Jantung Bawaan (PJB) adalah kelainan kongenital pada struktur dan fungsi sirkulasi. Morbiditas dan mortalitas PJB dipengaruhi berbagai faktor, seperti stat...
Penentuan Dimensi Sudu Turbin dan Sudut Kemiringan Poros Turbin pada Turbin Ular Archimedes
Penentuan Dimensi Sudu Turbin dan Sudut Kemiringan Poros Turbin pada Turbin Ular Archimedes
Abstrak  Telah dilakukan penelitian penentuan dimensi sudu turbin dan sudut kemiringan poros turbin pada turbin ulir Archimedes.  Penelitian ini melakukan kajian pada beberapa para...
PENGARUH BUKAAN SUDU PENGARAH TERHADAP KERUGIAN HEAD DAN PERFORMANSI TURBIN FRANCIS VERTIKAL
PENGARUH BUKAAN SUDU PENGARAH TERHADAP KERUGIAN HEAD DAN PERFORMANSI TURBIN FRANCIS VERTIKAL
Pembangkit Listrik Tenaga Air masih menjadi tumpuan utama pembangkitan energi listrik di dunia khususnya Indonesia.Data pada tahun 2006 menunjukan bahwa hampir 20% kebutuhan listri...