Javascript must be enabled to continue!
Dentinal Hypersensitivity Treatment with 1064 nm and 980 nm Diode Laser
View through CrossRef
Dentinal Hypersensitivity (DH), a prevalent oral health issue affecting approximately one-third of adults. In this six-months retrospective study, a comparison was made to assess the effectiveness of two diode lasers with different wavelengths (980 nm and 1064 nm) in the treatment of tooth affected by DH. In total, 160 patients were divided into two treatment groups: one receiving treatment with a 980 nm diode laser (n=80) and the other with a 1064 nm diode laser (n=80). Pain was assessed using the Visual Analogue Scale (VAS) at baseline, immediately post-treatment, and at 3- and 6-months follow-up. Both groups followed the same treatment protocol, involving the application of a graphite paste to the exposed dentin before laser irradiation. Both lasers operated at an output power of 0.5 W in continuous and non-contact mode, with a 320 µm spot size. A significant reduction in mean VAS scores at all follow-up intervals compared to baseline was noted. 980 nm group had mean VAS scores of 7.9, 2.36, 2.31, and 2.38, while the 1064 nm group had scores of 8.01, 1.01, 1.16, and 1.13 at baseline, immediately post-treatment, and at 3 and 6 months, respectively. At all times of follow-up, the 1064 nm wavelengths showed a statistically significant reduction in mean values of VAS compared to the 980 nm. The findings may inform future research on optimizing laser-based treatments for DH.
Title: Dentinal Hypersensitivity Treatment with 1064 nm and 980 nm Diode Laser
Description:
Dentinal Hypersensitivity (DH), a prevalent oral health issue affecting approximately one-third of adults.
In this six-months retrospective study, a comparison was made to assess the effectiveness of two diode lasers with different wavelengths (980 nm and 1064 nm) in the treatment of tooth affected by DH.
In total, 160 patients were divided into two treatment groups: one receiving treatment with a 980 nm diode laser (n=80) and the other with a 1064 nm diode laser (n=80).
Pain was assessed using the Visual Analogue Scale (VAS) at baseline, immediately post-treatment, and at 3- and 6-months follow-up.
Both groups followed the same treatment protocol, involving the application of a graphite paste to the exposed dentin before laser irradiation.
Both lasers operated at an output power of 0.
5 W in continuous and non-contact mode, with a 320 µm spot size.
A significant reduction in mean VAS scores at all follow-up intervals compared to baseline was noted.
980 nm group had mean VAS scores of 7.
9, 2.
36, 2.
31, and 2.
38, while the 1064 nm group had scores of 8.
01, 1.
01, 1.
16, and 1.
13 at baseline, immediately post-treatment, and at 3 and 6 months, respectively.
At all times of follow-up, the 1064 nm wavelengths showed a statistically significant reduction in mean values of VAS compared to the 980 nm.
The findings may inform future research on optimizing laser-based treatments for DH.
Related Results
Comparative Efficacy of Diode, Nd:YAG and Er:YAG Lasers Accompanied by Fluoride in Dentinal Tubule Obstruction
Comparative Efficacy of Diode, Nd:YAG and Er:YAG Lasers Accompanied by Fluoride in Dentinal Tubule Obstruction
Introduction: Recently, the management of dentin hypersensitivity by lasers has gained special attention. This study aimed to assess and compare the efficacy of the 980 nm diode, N...
RADIATING THE WAY TO DESENSITIZATION
RADIATING THE WAY TO DESENSITIZATION
INTRODUCTION
Dentinal hypersensitivity is a common clinical condition and the treatment outcome is not consistently successful with any particular treatment modalities. Two chief m...
Effect of DPSS Nd: YAG (532 nm) and diode (980 nm) laser treatment on fluoride uptake in dentin following silver diamine fluoride application: An in vitro study
Effect of DPSS Nd: YAG (532 nm) and diode (980 nm) laser treatment on fluoride uptake in dentin following silver diamine fluoride application: An in vitro study
Abstract
Fluoride treatment has long been recognized as an important method for treating dental decay. Silver Diamine Fluoride (SDF) treatment has emerged as a lo...
Surface and Mineral Changes of Primary Enamel After Laser Diode Irradiation and Application of Remineralization Agents: A Comparative In Vitro Study
Surface and Mineral Changes of Primary Enamel After Laser Diode Irradiation and Application of Remineralization Agents: A Comparative In Vitro Study
Aim: The purpose of this study is to evaluate the remineralization potential of primary teeth enamel after being exposed to different laser diode therapy. Methods: Ninety-six vesti...
Surface and Mineral Changes of Primary Enamel after Laser Diode Irradiation and Application of Remineralization Agents: A Comparative In Vitro Study
Surface and Mineral Changes of Primary Enamel after Laser Diode Irradiation and Application of Remineralization Agents: A Comparative In Vitro Study
Objectives: The purpose of this study is to evaluate the remineralization potential of primary teeth enamel after being exposed to different laser diode therapies. Methods: Ninety-...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract
Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
Hydrodynamics of dental dentinal fluid
Hydrodynamics of dental dentinal fluid
Background. Dentinal fluid is very close in its physical and mechanical properties and composition to blood plasma, which makes it a potentially aggressive biological environment f...
Utilizing Laser-Induced Fluorescence to Evaluate the Efficiency of Carbon Dioxide and Diode Lasers in Dentin Sealing after Tooth Preparation: An in-vitro Study
Utilizing Laser-Induced Fluorescence to Evaluate the Efficiency of Carbon Dioxide and Diode Lasers in Dentin Sealing after Tooth Preparation: An in-vitro Study
Abstract
Adhesive dentistry has made it feasible to design restorations with high aesthetic qualities and little invasiveness. However, the freshly cut dentin after the t...

