Javascript must be enabled to continue!
Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing
View through CrossRef
Multi-camera systems are widely applied in the three dimensional (3D) computer vision, especially when multiple cameras are distributed on both sides of the measured object. The calibration methods of multi-camera systems are critical to the accuracy of vision measurement and the key is to find an appropriate calibration target. In this paper, a high-precision camera calibration method for multi-camera systems based on transparent glass checkerboards and ray tracing is described, and is used to calibrate multiple cameras distributed on both sides of the glass checkerboard. Firstly, the intrinsic parameters of each camera are obtained by Zhang’s calibration method. Then, multiple cameras capture several images from the front and back of the glass checkerboard with different orientations, and all images contain distinct grid corners. As the cameras on one side are not affected by the refraction of glass checkerboard, extrinsic parameters can be directly calculated. However, the cameras on the other side are influenced by the refraction of glass checkerboard, and the direct use of projection model will produce a calibration error. A multi-camera calibration method using refractive projection model and ray tracing is developed to eliminate this error. Furthermore, both synthetic and real data are employed to validate the proposed approach. The experimental results of refractive calibration show that the error of the 3D reconstruction is smaller than 0.2 mm, the relative errors of both rotation and translation are less than 0.014%, and the mean and standard deviation of reprojection error of the four-camera system are 0.00007 and 0.4543 pixels, respectively. The proposed method is flexible, highly accurate, and simple to carry out.
Title: Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing
Description:
Multi-camera systems are widely applied in the three dimensional (3D) computer vision, especially when multiple cameras are distributed on both sides of the measured object.
The calibration methods of multi-camera systems are critical to the accuracy of vision measurement and the key is to find an appropriate calibration target.
In this paper, a high-precision camera calibration method for multi-camera systems based on transparent glass checkerboards and ray tracing is described, and is used to calibrate multiple cameras distributed on both sides of the glass checkerboard.
Firstly, the intrinsic parameters of each camera are obtained by Zhang’s calibration method.
Then, multiple cameras capture several images from the front and back of the glass checkerboard with different orientations, and all images contain distinct grid corners.
As the cameras on one side are not affected by the refraction of glass checkerboard, extrinsic parameters can be directly calculated.
However, the cameras on the other side are influenced by the refraction of glass checkerboard, and the direct use of projection model will produce a calibration error.
A multi-camera calibration method using refractive projection model and ray tracing is developed to eliminate this error.
Furthermore, both synthetic and real data are employed to validate the proposed approach.
The experimental results of refractive calibration show that the error of the 3D reconstruction is smaller than 0.
2 mm, the relative errors of both rotation and translation are less than 0.
014%, and the mean and standard deviation of reprojection error of the four-camera system are 0.
00007 and 0.
4543 pixels, respectively.
The proposed method is flexible, highly accurate, and simple to carry out.
Related Results
Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing
Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing
Multi-cameras system is widely applied in 3D computer vision especially when multiple cameras are distributed on both sides of the measured object. The calibration methods of multi...
Optimized global map projections for specific applications: the triptychial projection and the Spilhaus projection
Optimized global map projections for specific applications: the triptychial projection and the Spilhaus projection
<p>There is no perfect global map projection. A projection may be area preserving or conformal (shape preserving on small scales) in some regions, but it will inevita...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Principles and applications of pencil tracing
Principles and applications of pencil tracing
Pencil tracing, a new approach to ray tracing, is introduced for faster image synthesis with more physical fidelity. The paraxial approximation theory for efficiently tracing a pen...
Comparison of Visual Outcomes of Extended Depth of Focus Lenses in Patients With and Without Previous Laser Refractive Surgery
Comparison of Visual Outcomes of Extended Depth of Focus Lenses in Patients With and Without Previous Laser Refractive Surgery
PURPOSE:
To compare visual outcomes of eyes with and without previous laser refractive surgery that received an extended depth of focus intraocular lens during cataract...
IMPACT OF REFRACTIVE CORRECTION ON VISUAL FATIGUE, EYE MOVEMENT AND READING SPEED IN ADULTS
IMPACT OF REFRACTIVE CORRECTION ON VISUAL FATIGUE, EYE MOVEMENT AND READING SPEED IN ADULTS
Background
Refractive errors are a leading cause of visual impairment, significantly affecting daily activities that require sustained attention, such as reading. Uncorrected refra...
High-precision binocular camera calibration method based on a 3D calibration object
High-precision binocular camera calibration method based on a 3D calibration object
A high-precision binocular camera calibration method is proposed to address the issues of poor calibration accuracy and large calibration errors in current practical applications. ...
A calibration method combining hand-eye calibration and TCP calibration
A calibration method combining hand-eye calibration and TCP calibration
Abstract
Robots' traditional Tool Center Point (TCP) calibration and hand-eye calibration are implemented independently, which is likely to generate large cumulative errors...

