Research on optimisation of minimum air clearance of 1000 kV UHV AC substation
View through CrossRef
Based on air clearance discharge characteristic curve and insulation coordination method, it is pointed out that the minimum air clearance of 1000 kV ultra‐high voltage (UHV) AC substation can be further optimised. On the basis of analysis of the merits and demerits of the two insulation coordination methods for air clearances of UHV substation stated in the national standard GB/Z 24842–2009, it is concluded that using statistical method for insulation coordination is more reasonable and feasible. The minimum air clearance of UHV substation is optimised with the statistical method based on 1000 μs switching impulse characteristic test results. According to the study results, the phase‐to‐earth air clearance A1′ can be 1 m less than that specified in standard, the air clearance between conductors 0.5 m less than that specified in standard, and the phase‐to‐phase air clearance of grading ring and tubular bus 0.6 and 1.8 m, respectively, less than that specified in standard.
Institution of Engineering and Technology (IET)
Title: Research on optimisation of minimum air clearance of 1000 kV UHV AC substation
Description:
Based on air clearance discharge characteristic curve and insulation coordination method, it is pointed out that the minimum air clearance of 1000 kV ultra‐high voltage (UHV) AC substation can be further optimised.
On the basis of analysis of the merits and demerits of the two insulation coordination methods for air clearances of UHV substation stated in the national standard GB/Z 24842–2009, it is concluded that using statistical method for insulation coordination is more reasonable and feasible.
The minimum air clearance of UHV substation is optimised with the statistical method based on 1000 μs switching impulse characteristic test results.
According to the study results, the phase‐to‐earth air clearance A1′ can be 1 m less than that specified in standard, the air clearance between conductors 0.
5 m less than that specified in standard, and the phase‐to‐phase air clearance of grading ring and tubular bus 0.
6 and 1.
8 m, respectively, less than that specified in standard.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Research on overvoltage and minimum air clearance on 1000 kV AC side of converter transformer in ±1100 kV Guquan converter station
Research on overvoltage and minimum air clearance on 1000 kV AC side of converter transformer in ±1100 kV Guquan converter station
In the hierarchically connected ultra‐high voltage (UHV) DC projects, the minimum air clearance on the 1000 kV AC side of converter transformer directly affects the layout and area...
Tower Air‐gaps discharge characteristics and insulation coordination for UHV AC double‐circuit line
Tower Air‐gaps discharge characteristics and insulation coordination for UHV AC double‐circuit line
In order to give out inverse V‐type insulator tower air‐gaps configuration of double‐circuit UHV AC power transmission line, different distance air‐gaps from high‐voltage electrode...
Élimination des vapeurs toxiques par oxydation : développement de procédures d'évaluation des systèmes de purification de l'air des conduits de ventilation
Élimination des vapeurs toxiques par oxydation : développement de procédures d'évaluation des systèmes de purification de l'air des conduits de ventilation
L'exposition à des composés organiques volatils (COV) dans les lieux de travail peut avoir des effets aigus, notamment sous forme d'irritation de la peau, des yeux, de la bouche et...
A research based on testing method for the whole substation cascaded in digital substation
A research based on testing method for the whole substation cascaded in digital substation
Substation as an important component of the power grid, its safe and steady operation is crucial to the power grid. After building new substation or renovating the old ones, they n...
Life Cycle Cost Prediction of Substation Based on Advanced PSO and Least Squares Support Vector Machine
Life Cycle Cost Prediction of Substation Based on Advanced PSO and Least Squares Support Vector Machine
Abstract
The rapid prediction of the full life cycle cost of substation has guiding significance for the construction of substation. In this paper, a substation full...
Life Cycle Cost Analysis and Optimization of Modular Substation
Life Cycle Cost Analysis and Optimization of Modular Substation
Due to the lack of high standardization and specialization, the production scale of modular substation is difficult to meet the established requirements. Compared with traditional ...
To Assess the Effectiveness of Hypertonic Saline Nebulized Suctioning On Airway Clearance Among Patients On Mechanical Ventilator In Selected Hospitals
To Assess the Effectiveness of Hypertonic Saline Nebulized Suctioning On Airway Clearance Among Patients On Mechanical Ventilator In Selected Hospitals
OBJECTIVES- 1) To assess the airway clearance of patients on mechanical ventilator in experimental and control group in selected hospitals. 2) To assess the effectiveness of hypert...