Temperature Recording In Neonates by Non-Contact Thermometer Versus Routine Digital Thermometer - The Best Modality?

View through CrossRef
Introduction: Measurement of temperature in neonates should be accurate, reliable and reproducible, considering that they have a limited ability to regulate their own temperature. There is no ideal thermometer to measure temperature, however, there has been a constant endeavour to find more accurate and non-invasive means of measurement. The present study was conducted to find whether Non-Contact Infrared thermometers were as accurate as Digital Axillary thermometers in measuring temperatures in neonates. Methodology: This was a comparative diagnostic study, carried out in the maternity unit of a tertiary care hospital over a period of 6 weeks. A total of 154 neonates were recruited in the study through consecutive sampling and their temperatures recorded using Non-Contact Infrared Thermometer (NCIT) on forehead and Digital Axillary Thermometer (DAT) on axilla simultaneously. Results: The average temperature recording on forehead using NCIT and axilla using DAT, was in the range of 36 – 37oC, with the NCIT showing a higher recording as compared to the DAT. The mean difference between the two modalities was -0.46oC. A Bland-Altman plot analysis was done, in which majority of readings had wide variation, falling beyond the upper (0.57oC) and lower (-1.49oC) limits. A linear regression plot also showed a positive correlation between NCIT on forehead and DAT on axilla, with absolute R value = 0.2, which showed a weak correlation between the two. Conclusion: It was concluded that NCIT measurements on forehead are not as accurate as DAT measurements on axilla. However, a larger study, is needed to extrapolate these findings to the general population.    Conclusion: It was concluded that NCIT measurements on forehead are not as accurate as DAT measurements on axilla. However, a larger study, is needed to extrapolate these findings to the general population.
Title: Temperature Recording In Neonates by Non-Contact Thermometer Versus Routine Digital Thermometer - The Best Modality?
Description:
Introduction: Measurement of temperature in neonates should be accurate, reliable and reproducible, considering that they have a limited ability to regulate their own temperature.
There is no ideal thermometer to measure temperature, however, there has been a constant endeavour to find more accurate and non-invasive means of measurement.
The present study was conducted to find whether Non-Contact Infrared thermometers were as accurate as Digital Axillary thermometers in measuring temperatures in neonates.
Methodology: This was a comparative diagnostic study, carried out in the maternity unit of a tertiary care hospital over a period of 6 weeks.
A total of 154 neonates were recruited in the study through consecutive sampling and their temperatures recorded using Non-Contact Infrared Thermometer (NCIT) on forehead and Digital Axillary Thermometer (DAT) on axilla simultaneously.
Results: The average temperature recording on forehead using NCIT and axilla using DAT, was in the range of 36 – 37oC, with the NCIT showing a higher recording as compared to the DAT.
The mean difference between the two modalities was -0.
46oC.
A Bland-Altman plot analysis was done, in which majority of readings had wide variation, falling beyond the upper (0.
57oC) and lower (-1.
49oC) limits.
A linear regression plot also showed a positive correlation between NCIT on forehead and DAT on axilla, with absolute R value = 0.
2, which showed a weak correlation between the two.
Conclusion: It was concluded that NCIT measurements on forehead are not as accurate as DAT measurements on axilla.
However, a larger study, is needed to extrapolate these findings to the general population.
    Conclusion: It was concluded that NCIT measurements on forehead are not as accurate as DAT measurements on axilla.
However, a larger study, is needed to extrapolate these findings to the general population.

Related Results

Access Denied
Access Denied
Introduction As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer
A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer
Background: Sublingual temperature measurement is a quick and accurate representation of oral temperature and corresponds closely with core temperature. Sub-lin...
A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer
A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer
Background: Sublingual temperature measurement is a quick and accurate representation of oral temperature and corresponds closely with core temperature. Sub-lin...
A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer
A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer
Background: Sublingual temperature measurement is a quick and accurate representation of oral temperature and corresponds closely with core temperature. Sub-lin...
Association of Admission Temperature and Outcome among Neonates with Sepsis in a Tertiary Care Hospital
Association of Admission Temperature and Outcome among Neonates with Sepsis in a Tertiary Care Hospital
Background: Neonatal sepsis is a leading cause of mortality in the neonatal period, particularly in low- and middle-income countries. Temperature at admission may provide valuable ...
Temperature assessment in newborn: A better method
Temperature assessment in newborn: A better method
Abstract BACKGROUND Accurate temperature assessment is essential in neonatal care as minor temperature changes can have a significant impact on the health and well-being o...
Prediction model for rectal temperature in cats with different baseline characteristics using a non-contact infrared thermometer
Prediction model for rectal temperature in cats with different baseline characteristics using a non-contact infrared thermometer
Background and Aim: Body temperature is the most useful clinical parameter for evaluating animal health. In clinical practice, rectal temperature is the gold standard for assessing...
Does Gender Affect Levels of Hyperbilirubinemia in Term Neonates
Does Gender Affect Levels of Hyperbilirubinemia in Term Neonates
Introduction: Hyperbilirubinemia is a common & in most1cases, benign problem in1first month of1life which is often1physiologic & intervention is not1usually1necessary. In t...

Back to Top