Clinical accuracy and agreement between tympanic and forehead body temperature measurements for screening of patients with COVID‐19

View through CrossRef
AbstractAimTo investigate the accuracy, reliability and agreement between infrared forehead thermometers versus infrared tympanic thermometers temperature, a cross‐sectional study was conducted in April 2020.MethodsThe forehead and tympanic temperatures of 615 subjects were measured simultaneously in three exposed SARS‐COV‐2 groups at one hospital in Iran, during April 2020. These comparisons were evaluated by Bland–Altman Plot, repeatability, Passing–Bablok regression and Lin's concordance correlation coefficient. The receiver operating characteristic (ROC) analysis was done to describe the discrimination accuracy of a diagnostic test. The study adhered to STROBE checklist for cross‐sectional studies.ResultsA Bland–Altman plot indicated that the limits of agreement between the forehead and tympanic temperature were −0.259 to +0.19°C. Passing–Bablok regression analysis illustrated that the infrared forehead was not linearly related to tympanic temperatures (reference method), with a slope estimate that was significantly different from 1.00. The infrared forehead thermometer showed poor precision and lower accuracy than the tympanic. The forehead temperature readings had 60.0% sensitivity and 44.4% specificity (p > .05) to predict disease.ConclusionAccording to the results of study, there is no evidence that the assessment of temperature by infrared forehead thermometer could discriminate between the two groups (positive and negative).
Title: Clinical accuracy and agreement between tympanic and forehead body temperature measurements for screening of patients with COVID‐19
Description:
AbstractAimTo investigate the accuracy, reliability and agreement between infrared forehead thermometers versus infrared tympanic thermometers temperature, a cross‐sectional study was conducted in April 2020.
MethodsThe forehead and tympanic temperatures of 615 subjects were measured simultaneously in three exposed SARS‐COV‐2 groups at one hospital in Iran, during April 2020.
These comparisons were evaluated by Bland–Altman Plot, repeatability, Passing–Bablok regression and Lin's concordance correlation coefficient.
The receiver operating characteristic (ROC) analysis was done to describe the discrimination accuracy of a diagnostic test.
The study adhered to STROBE checklist for cross‐sectional studies.
ResultsA Bland–Altman plot indicated that the limits of agreement between the forehead and tympanic temperature were −0.
259 to +0.
19°C.
Passing–Bablok regression analysis illustrated that the infrared forehead was not linearly related to tympanic temperatures (reference method), with a slope estimate that was significantly different from 1.
00.
The infrared forehead thermometer showed poor precision and lower accuracy than the tympanic.
The forehead temperature readings had 60.
0% sensitivity and 44.
4% specificity (p > .
05) to predict disease.
ConclusionAccording to the results of study, there is no evidence that the assessment of temperature by infrared forehead thermometer could discriminate between the two groups (positive and negative).

Related Results

Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Abstract Introduction The exact manner in which large language models (LLMs) will be integrated into pathology is not yet fully comprehended. This study examines the accuracy, bene...
KECEMASAN SAAT PANDEMI COVID 19: LITERATUR REVIEW Hardiyati, Efri Widianti, Taty Hernawaty Departemen Keperawatan Jiwa Poltekkes Kemenkes Mamuju Sulbar, Universitas Pad...
Tijelo u opusu Janka Polića Kamova
Tijelo u opusu Janka Polića Kamova
The doctoral disertation is dedicated to the concept of the body in the works of Janko Polić Kamov. The body is approached as a signifier system on the basis of which numerous and ...
Hearing assessment and status of tympanic membrane pre and post-operated tympanoplasty in cases of CSOM.
Hearing assessment and status of tympanic membrane pre and post-operated tympanoplasty in cases of CSOM.
Objectives: To compare assessment of hearing by PTA and status of tympanic membrane by oto-endoscope, pre-operative and post-operative tympanoplasty. Study Design: Retrospective/ C...
Burden of the Beast
Burden of the Beast
Introduction Throughout the COVID-19 pandemic, and its fluctuating waves of infections and the emergence of new variants, Indigenous populations in Australia and worldwide have re...
Diagnostic Agreement Study: Otoscopy vs Tympanometry in Otitis Media with Effusion
Diagnostic Agreement Study: Otoscopy vs Tympanometry in Otitis Media with Effusion
Background: Otitis media with effusion is a common pediatric condition leading to hearing impairment. Accurate diagnosis is essential and relies primarily on otoscopy and tympanome...
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
Abstract Introduction Human immunodeficiency virus (HIV) and Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV2) surface glycoproteins, including shared epitope motifs, sho...

Back to Top