Investigation of some regular x-ray imaging parameters in suggestive radiography of four hospitals in Bangladesh
View through CrossRef
Analytic radiography is a normal image testing technique which has been utilized for quite a long time. It is recommended by specialists so they can identify any problem in patients' bodies without a cut. Thinking about its wide use, the principle objective of this investigation is to give a top notch picture by keeping the radiation portion as low as conceivable through identifying any variety in quality control (QC) boundaries. In this work, some standard quality control boundaries, for example, voltage exactness, time precision test, tube yield linearity, half value layer (HVL) of x-beam were measured. These quality control (QC) boundaries were estimated by a dosimeter keeping a distance of 100 cm from source. The voltage precision went from 0.31% to 4.67% and the time exactness test went from 0% to 2.29%. The consequences of this investigation show that all the QC boundaries are inside the acceptable level which guarantees the advancement of the low portion conveyed to the patients.
Institute for Research and Development, Suan Sunandha Rajabhat University
Title: Investigation of some regular x-ray imaging parameters in suggestive radiography of four hospitals in Bangladesh
Description:
Analytic radiography is a normal image testing technique which has been utilized for quite a long time.
It is recommended by specialists so they can identify any problem in patients' bodies without a cut.
Thinking about its wide use, the principle objective of this investigation is to give a top notch picture by keeping the radiation portion as low as conceivable through identifying any variety in quality control (QC) boundaries.
In this work, some standard quality control boundaries, for example, voltage exactness, time precision test, tube yield linearity, half value layer (HVL) of x-beam were measured.
These quality control (QC) boundaries were estimated by a dosimeter keeping a distance of 100 cm from source.
The voltage precision went from 0.
31% to 4.
67% and the time exactness test went from 0% to 2.
29%.
The consequences of this investigation show that all the QC boundaries are inside the acceptable level which guarantees the advancement of the low portion conveyed to the patients.
Related Results
The role of chest radiography in the diagnosis of bacteriologically confirmed pulmonary tuberculosis in hospitalised Xpert MTB/RIF-negative patients
The role of chest radiography in the diagnosis of bacteriologically confirmed pulmonary tuberculosis in hospitalised Xpert MTB/RIF-negative patients
The role of chest radiography to diagnose active tuberculosis in symptomatic patients who have a negative Xpert MTB/RIF (Xpert) test result is unclear. This study aimed to assess t...
Orthopedic Injury Diagnosis Using Digital Radiography: A Retrospective Study
Orthopedic Injury Diagnosis Using Digital Radiography: A Retrospective Study
Background: Hundred patients were examined to determine the effectiveness of digital radiography in detecting Orthopedic injuries. The decisive findings showed that digital radiogr...
Comparative Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Bone Fractures
Comparative Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Bone Fractures
Background: Bone fractures represent a substantial proportion of cases presenting to emergency and orthopedic departments worldwide, including in resource-limited settings like Nis...
Low-dose, X-ray-based Imaging of Lung Function
Low-dose, X-ray-based Imaging of Lung Function
<p>Chronic obstructive pulmonary disease (COPD) is characterized by chronic airflow limitation resulting from emphysema and small airway disease. Functional lung imaging of C...
Low-dose, X-ray-based Imaging of Lung Function
Low-dose, X-ray-based Imaging of Lung Function
<p>Chronic obstructive pulmonary disease (COPD) is characterized by chronic airflow limitation resulting from emphysema and small airway disease. Functional lung imaging of C...
K-Regular Matroids
K-Regular Matroids
<p>The class of matroids representable over all fields is the class of regular matroids. The class of matroids representable over all fields except perhaps GF(2) is the class...
Market Shares for Rural Inpatient Surgical Services: Where Does the Buck Stop?
Market Shares for Rural Inpatient Surgical Services: Where Does the Buck Stop?
ABSTRACT:Utilization of surgical services by rural citizens is poorly understood, and few data are available about rural hospitals’surgical market shares and their financial implic...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...