Javascript must be enabled to continue!
33 Use of novel global ultrasound imaging and continuous dipole density mapping to guide ablation in macro-reentrant tachycardias
View through CrossRef
Introduction
Persistent AF (PeAF) ablation continues to be a challenge, primarily because the mechanism of AF is not clearly defined and even when successfully ablated may evolve into multiple atrial tachycardias or flutters (AT/AFl) during the course of a procedure. Sequential mapping with existing 3D mapping systems can make procedures long and complex. We report the use of a novel simultaneous non-contact ultrasound (US) imaging and mapping system (AcQMap) to characterise of AT/AFl during PeAF ablation.
Methods
The AcQMap system consists of a basket catheter (48 US transducers, 48 electrodes) which simultaneously acquires 100,000+ US points/min to reconstruct chamber anatomy and 1 50 000 intracardiac unipolar voltage points/s to map cardiac activity. The 3D surface is algorithmically reconstructed from the US point-set with mesh-density comparable to a segmented CT.1 Inverse and forward algorithms are applied on intracardiac voltage to derive and display electrical activation as dipole density™ (DD) and unipolar voltage maps respectively, upon the US-constructed 3D anatomy.
Results
Data were collected from three patients booked for a first PeAF ablation (2 male, age 48±13 years, time in PerAF 1.7±1.2 years) who also demonstrated AT/AFl either before or during the procedure. All patients had previously failed DCCV and were receiving amiodarone. The AcQMap system was used to measure cardiac voltage, apply its DD algorithm and display electrical activation on the US constructed 3D anatomy to demonstrate the AFl/AT circuit. The circuit was validated using contact mapping and response to ablation. Left atrial (LA) and (right atrial) RA surface acquisition times were 296±20 s and 209±88 s respectively.
The maps demonstrated a macro-reentrant circuit in all patients and were used to guide ablation at the isthmus of the circuit. Procedural end point was bidirectional block. Patient 1 presented in typical right AFl (figure 1); Patient 2 presented in SR but with an easily inducible AT around the right upper PV; Patient 3 presented in AF which organised to an AT around the LA posterior wall, and after ablation and termination of this, subsequently to a typical right AFl. Figure 2 shows a Dd-based isochronal plot of the initial AT activation sequence from Patient 3, with breakout at the inferior aspect of the LA posterior wall. All AT/AFl terminated during formation of the ablation line. Maps were then created in SR, and during pacing to demonstrate bidirectional block.
Conclusions
Real-time US and DD based LA and RA reconstructions using the AcQMap system provide high resolution electro-anatomical maps, allowing rapid and accurate targeting of critical isthmuses for ablation of macro-reentrant AT/AFl. This technique also raises the possibility of mapping AF with more precision to identify areas of interest as potential ablation targets.
Reference
1. Heck PM et al. Europace 2015;17(s5):6–9.
Abstract 33 Figure 1
Abstract 33 Figure 2
Title: 33 Use of novel global ultrasound imaging and continuous dipole density mapping to guide ablation in macro-reentrant tachycardias
Description:
Introduction
Persistent AF (PeAF) ablation continues to be a challenge, primarily because the mechanism of AF is not clearly defined and even when successfully ablated may evolve into multiple atrial tachycardias or flutters (AT/AFl) during the course of a procedure.
Sequential mapping with existing 3D mapping systems can make procedures long and complex.
We report the use of a novel simultaneous non-contact ultrasound (US) imaging and mapping system (AcQMap) to characterise of AT/AFl during PeAF ablation.
Methods
The AcQMap system consists of a basket catheter (48 US transducers, 48 electrodes) which simultaneously acquires 100,000+ US points/min to reconstruct chamber anatomy and 1 50 000 intracardiac unipolar voltage points/s to map cardiac activity.
The 3D surface is algorithmically reconstructed from the US point-set with mesh-density comparable to a segmented CT.
1 Inverse and forward algorithms are applied on intracardiac voltage to derive and display electrical activation as dipole density™ (DD) and unipolar voltage maps respectively, upon the US-constructed 3D anatomy.
Results
Data were collected from three patients booked for a first PeAF ablation (2 male, age 48±13 years, time in PerAF 1.
7±1.
2 years) who also demonstrated AT/AFl either before or during the procedure.
All patients had previously failed DCCV and were receiving amiodarone.
The AcQMap system was used to measure cardiac voltage, apply its DD algorithm and display electrical activation on the US constructed 3D anatomy to demonstrate the AFl/AT circuit.
The circuit was validated using contact mapping and response to ablation.
Left atrial (LA) and (right atrial) RA surface acquisition times were 296±20 s and 209±88 s respectively.
The maps demonstrated a macro-reentrant circuit in all patients and were used to guide ablation at the isthmus of the circuit.
Procedural end point was bidirectional block.
Patient 1 presented in typical right AFl (figure 1); Patient 2 presented in SR but with an easily inducible AT around the right upper PV; Patient 3 presented in AF which organised to an AT around the LA posterior wall, and after ablation and termination of this, subsequently to a typical right AFl.
Figure 2 shows a Dd-based isochronal plot of the initial AT activation sequence from Patient 3, with breakout at the inferior aspect of the LA posterior wall.
All AT/AFl terminated during formation of the ablation line.
Maps were then created in SR, and during pacing to demonstrate bidirectional block.
Conclusions
Real-time US and DD based LA and RA reconstructions using the AcQMap system provide high resolution electro-anatomical maps, allowing rapid and accurate targeting of critical isthmuses for ablation of macro-reentrant AT/AFl.
This technique also raises the possibility of mapping AF with more precision to identify areas of interest as potential ablation targets.
Reference
1.
Heck PM et al.
Europace 2015;17(s5):6–9.
Abstract 33 Figure 1
Abstract 33 Figure 2.
Related Results
Stabilization of unstable reentrant atrial tachycardias via fractionated continuous electrical activity ablation (CHAOS study)
Stabilization of unstable reentrant atrial tachycardias via fractionated continuous electrical activity ablation (CHAOS study)
Abstract
Funding Acknowledgements
Type of funding sources: None.
Background. Unstable reentrant atrial tachyca...
Case report: Para Hisian Atrial Tachycardia
Case report: Para Hisian Atrial Tachycardia
Atrial tachycardia accounts for around 10% of supraventricular tachycardias (1). Atrial tachycardia can either be focal or macrorenentrant. Focal AT usually start at a focal p...
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
Introduction:
Novel ablation catheters equipped with
mini-electrodes (ME) offer high resolution mapping for target tissue.
This study aimed to evaluate the mappin...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract
Introduction
Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
Stabilization of unstable reentrant atrial tachycardias via fractionated continuous electrical activity ablation (CHAOS study).
Stabilization of unstable reentrant atrial tachycardias via fractionated continuous electrical activity ablation (CHAOS study).
Introduction. Unstable reentrant atrial tachycardias (ATs) (i.e. those
with frequent circuit modification or conversion to atrial fibrillation)
are challenging to ablate. We have t...
Linking White‐Tailed Deer Density, Nutrition, and Vegetation in a Stochastic Environment
Linking White‐Tailed Deer Density, Nutrition, and Vegetation in a Stochastic Environment
ABSTRACT
Density‐dependent behavior underpins white‐tailed deer (
Odocoileus virginianus
) theory and...
Mapping workflow trends in pulsed-field ablation procedures: an international glimpse
Mapping workflow trends in pulsed-field ablation procedures: an international glimpse
Abstract
Background
As pulsed field ablation (PFA) is increasingly used in the EP lab, the use of mapping, fluoroscopy, and intr...
The Burden of Road Traffic Injuries: A Global Perspective
The Burden of Road Traffic Injuries: A Global Perspective
Introduction Road Traffic Injury (RTI) pose a significant health challenge. It represents the eighth leading cause of death globally, prompting the UN to designate 2011-2020 as...

