Javascript must be enabled to continue!
Fermi level determination in organic thin films by the Kelvin probe method
View through CrossRef
We show that the Kelvin probe method (KPM) is well suited for in situ measurements of the Fermi level of organic vapor-deposited dye layers. The method works well even for high resistivity materials, is nondestructive, and does not need any top contacts. First results for zinc-phthalocyanine (ZnPc) and perfluorinated ZnPc (ZnPc–F16) are presented. The KPM results show that a 2.5% admixture of ZnPc–F16 to a ZnPc matrix leads to a 0.2 eV lowering of the Fermi level of ZnPc, i.e., ZnPc–F16 has acceptorlike properties relative to ZnPc.
Title: Fermi level determination in organic thin films by the Kelvin probe method
Description:
We show that the Kelvin probe method (KPM) is well suited for in situ measurements of the Fermi level of organic vapor-deposited dye layers.
The method works well even for high resistivity materials, is nondestructive, and does not need any top contacts.
First results for zinc-phthalocyanine (ZnPc) and perfluorinated ZnPc (ZnPc–F16) are presented.
The KPM results show that a 2.
5% admixture of ZnPc–F16 to a ZnPc matrix leads to a 0.
2 eV lowering of the Fermi level of ZnPc, i.
e.
, ZnPc–F16 has acceptorlike properties relative to ZnPc.
Related Results
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Phillip Noyce is one of Australia’s most prominent film makers—a successful feature film director with both iconic Australian narratives and many a Hollywood blockbuster under his ...
Desarrollo de nuevas estructuras laminares de nanocelulosa con propiedades avanzadas para el packaging
Desarrollo de nuevas estructuras laminares de nanocelulosa con propiedades avanzadas para el packaging
(English) Changes in the use of raw materials and major lifestyle changes in first world societies have driven the massive use of petroleum-based materials in a wide range of appli...
Spray Coated Nanocellulose Films Productions, Characterization and Application
Spray Coated Nanocellulose Films Productions, Characterization and Application
Nanocellulose (NC) is a biodegradable, renewable and sustainable material. It has strong potential to use as a functional material in various applications such as barriers, coating...
Study on equation of state based on Thomas-Fermi-Kirzhnits model
Study on equation of state based on Thomas-Fermi-Kirzhnits model
A wide-range semi-empirical equation of state is constructed for numerical simulation of high-energy density experiments, such as, wire-array Z-pinch etc. The equation of state con...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
A harmonic projection and least–squares method for quantifying Kelvin wave activity
A harmonic projection and least–squares method for quantifying Kelvin wave activity
Abstract. A new method for isolating the equatorial and coastal Kelvin wave signal from alongtrack satellite altimetry data is presented and applied to sea level anomaly (SLA) obse...
Does Xpert MTB/RIF Assay Give Rifampicin Resistance Results Without Identified Mutation? Review of Cases from Addis Ababa, Ethiopia.
Does Xpert MTB/RIF Assay Give Rifampicin Resistance Results Without Identified Mutation? Review of Cases from Addis Ababa, Ethiopia.
Abstract
Background: Xpert® MTB/RIF assay is currently used in Ethiopia for the rapid diagnosis of Mycobacterium tuberculosis (MTB) and mutations that confer Rifampicin res...
Does Xpert MTB/RIF Assay Give Rifampicin Resistance Results Without Identified Mutation? Review of Cases from Addis Ababa, Ethiopia.
Does Xpert MTB/RIF Assay Give Rifampicin Resistance Results Without Identified Mutation? Review of Cases from Addis Ababa, Ethiopia.
Abstract
Background: Xpert MTB/RIF Assay is currently used in Ethiopia for the rapid diagnosis of Mycobacterium tuberculosis (MTB) and mutations that confer Rifampicin resi...

