Low Cost Non-İnvasive Portable Monitor Platform for Cardiac Biopotential and Transthoracic Impedance Measurements

View through CrossRef
Abstract Purpose Simultaneous monitoring of ECG and thoracic electrical bioimpedance (TEB) is important in evaluating cardiovascular performance. TEB is a non-invasive technique based on measuring the impedance value that changes in the chest area depending on the heartbeat. Within the framework of this study, it can be used in home monitoring and biotelemetry applications to measure thoracic electrical bioimpedance (TEB), ECG and ICG. Methods Within the scope of this study, a four-electrode TEB measurement system was designed and built using the Raspberry Pi single board computer and its original monitor, ESP32 and EVAL-ADAS1000SDZ evaluation board. With the designed system, ECG and thoracic impedance measurements at 50 kHz current frequency were taken as real-time over a single channel. Delta_Z and ICG signals were created from thoracic impedance values with the developed software.ResultsWhile the thoracic impedance value varies between 15-45 Ω, the 67 thoracic impedance value measured with the designed system is approximately 1000 times the 68 reference value. The impedance change in the thoracic region was measured with the designed 69 system between 0.1-0.2 Ω values, and the compatibility of these values with reference values was 70 determined. While the reference value of the dZ / dt signal is 0.8 - 3.5 Ω / s, this value is between 2.3 - 71 5.3 Ω / s in the measurements taken with the designed system.Conclusion The prototype is achieved in detecting small changes in the thoracic impedance signal. The prototype is cheap, portable, small-sized and medically safe, so it is suitable for home care services and clinics. In addition, the developed system can be adapted to wearable technology. In order to increase the success of the system, the impedances values added to the thoracic impedance value should be determined and a calibration procedure should be established.
Springer Science and Business Media LLC
Title: Low Cost Non-İnvasive Portable Monitor Platform for Cardiac Biopotential and Transthoracic Impedance Measurements
Description:
Abstract Purpose Simultaneous monitoring of ECG and thoracic electrical bioimpedance (TEB) is important in evaluating cardiovascular performance.
TEB is a non-invasive technique based on measuring the impedance value that changes in the chest area depending on the heartbeat.
Within the framework of this study, it can be used in home monitoring and biotelemetry applications to measure thoracic electrical bioimpedance (TEB), ECG and ICG.
Methods Within the scope of this study, a four-electrode TEB measurement system was designed and built using the Raspberry Pi single board computer and its original monitor, ESP32 and EVAL-ADAS1000SDZ evaluation board.
With the designed system, ECG and thoracic impedance measurements at 50 kHz current frequency were taken as real-time over a single channel.
Delta_Z and ICG signals were created from thoracic impedance values with the developed software.
ResultsWhile the thoracic impedance value varies between 15-45 Ω, the 67 thoracic impedance value measured with the designed system is approximately 1000 times the 68 reference value.
The impedance change in the thoracic region was measured with the designed 69 system between 0.
1-0.
2 Ω values, and the compatibility of these values with reference values was 70 determined.
While the reference value of the dZ / dt signal is 0.
8 - 3.
5 Ω / s, this value is between 2.
3 - 71 5.
3 Ω / s in the measurements taken with the designed system.
Conclusion The prototype is achieved in detecting small changes in the thoracic impedance signal.
The prototype is cheap, portable, small-sized and medically safe, so it is suitable for home care services and clinics.
In addition, the developed system can be adapted to wearable technology.
In order to increase the success of the system, the impedances values added to the thoracic impedance value should be determined and a calibration procedure should be established.

Related Results

EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Cardiac Myxoma Post-Transseptal Ablation: Coincidence or Causation?
Cardiac Myxoma Post-Transseptal Ablation: Coincidence or Causation?
Background: Cardiac myxomas are benign cardiac neoplasms usually found solitarily located within a single cardiac chamber, most commonly in the left atrium. With no established cau...
Me-Doped Ti–Me Intermetallic Thin Films Used for Dry Biopotential Electrodes: A Comparative Case Study
Me-Doped Ti–Me Intermetallic Thin Films Used for Dry Biopotential Electrodes: A Comparative Case Study
In a new era for digital health, dry electrodes for biopotential measurement enable the monitoring of essential vital functions outside of specialized healthcare centers. In this p...
Instrumental modeling of Mutual Impedance experiments and validation tests in plasma chamber
Instrumental modeling of Mutual Impedance experiments and validation tests in plasma chamber
<p>Mutual impedance experiments are in situ space plasma diagnostic techniques for the determination of characteristic plasma parameters, such as the plasma density a...
Sondes à impédance mutuelle pour plateformes nanosatellite
Sondes à impédance mutuelle pour plateformes nanosatellite
Mutual impedance probes for nanosatellite platforms Les sondes à impédance mutuelle sont des expériences spatiales de diagnostic utilisées pour mesurer in situ la d...
(Keynote) On Interpretation of Impedance Spectroscopy Data
(Keynote) On Interpretation of Impedance Spectroscopy Data
Impedance spectroscopy represents a rich area of science that has been applied to many research disciplines, including those associated with corrosion and corrosion control, energy...
The biology of incipient, pre-invasive or intraepithelial neoplasia
The biology of incipient, pre-invasive or intraepithelial neoplasia
Invasive tumors (cancers or malignant lesions) typically develop in the setting in which there is the presence of putative non-invasive lesions and the development of these non-inv...

Back to Top