Javascript must be enabled to continue!
Femtosecond Phase and Amplitude Controlled, Chirped Pulse Amplification: Terawatts to Petawatts
View through CrossRef
Chirped pulse amplification at 10 fs and powers > 1 TW faces many challenges. In conventional CPA systems, uncompensatable phase errors in the expansion and recompression process and distortions due to refractive optics produce broadenings which are much greater than 10 fs. In order to alleviate these problems, a novel expander/compressor design has been developed and a lens-free amplification system has been constructed. In addition, gain narrowing during amplification severely limits the final pulse duration. In order to control the pulse spectrum before amplification and thus minimize this problem, spectral masks have also been developed and implemented. The result is a compact multiterawatt laser system capable of producing 125-mJ, 30-fs, 800-nm pulses with near diffraction limited beam quality at a repetition rate of 10 Hz. Ongoing experiments with this 4 TW system include hard x-ray generation for diagnostic imaging, tunneling ionization XUV lasers, and tunable ultrashort pulse, high power IR generation. Because the design of this system can accommodate much larger bandwidth pulses and very large amounts of dispersive material, it is possible to directly scale these results to shorter durations and petawatt peak powers. Such a system could be constructed from currently available optical materials and components and would be capable of producing focused intensities > 1022 W/cm2.
Title: Femtosecond Phase and Amplitude Controlled, Chirped Pulse Amplification: Terawatts to Petawatts
Description:
Chirped pulse amplification at 10 fs and powers > 1 TW faces many challenges.
In conventional CPA systems, uncompensatable phase errors in the expansion and recompression process and distortions due to refractive optics produce broadenings which are much greater than 10 fs.
In order to alleviate these problems, a novel expander/compressor design has been developed and a lens-free amplification system has been constructed.
In addition, gain narrowing during amplification severely limits the final pulse duration.
In order to control the pulse spectrum before amplification and thus minimize this problem, spectral masks have also been developed and implemented.
The result is a compact multiterawatt laser system capable of producing 125-mJ, 30-fs, 800-nm pulses with near diffraction limited beam quality at a repetition rate of 10 Hz.
Ongoing experiments with this 4 TW system include hard x-ray generation for diagnostic imaging, tunneling ionization XUV lasers, and tunable ultrashort pulse, high power IR generation.
Because the design of this system can accommodate much larger bandwidth pulses and very large amounts of dispersive material, it is possible to directly scale these results to shorter durations and petawatt peak powers.
Such a system could be constructed from currently available optical materials and components and would be capable of producing focused intensities > 1022 W/cm2.
Related Results
Study of the multipass amplification of the chirped pulse and its inverse problem
Study of the multipass amplification of the chirped pulse and its inverse problem
The multipass amplification characters of the chirped pulse in gain medium were studied with the Schrdinger equation and population equation. The inverse problem of multipass ampl...
Amplification characteristics of N<i/>2+ lasing at multiple wavelengths generated by polarization-modulated femtosecond laser fields
Amplification characteristics of N<i/>2+ lasing at multiple wavelengths generated by polarization-modulated femtosecond laser fields
Multiple gain routes complicate the amplification behaviors of N2+ lasing. A direct comparison of the amplification processes of various lasing lines of N2+ is still lacking to dat...
Femtosecond pulse shaping technology and its applications
Femtosecond pulse shaping technology and its applications
By controlling the spectral amplitude, phase and polarization of the femtosecond laser pulse in the frequency domain, a shaped femtosecond laser pulse with almost arbitrary pulse s...
Study on the extremely large seismic ground motion amplification on weak-motion seismograms from the Gongquan valley
Study on the extremely large seismic ground motion amplification on weak-motion seismograms from the Gongquan valley
The Ms 6.0 Changning Earthquake in 2019 caused severe damage to Gongquan Town, Sichuan. Our on-site investigation of seismic damage found that the three-dimensional topography and ...
Data Mining of Tongue and Pulse based on Tongue Diagnosis and Pulse Diagnosis Instruments:Evaluation of Machine-Learning Assisting Classification of Fatigue Subjects (Preprint)
Data Mining of Tongue and Pulse based on Tongue Diagnosis and Pulse Diagnosis Instruments:Evaluation of Machine-Learning Assisting Classification of Fatigue Subjects (Preprint)
BACKGROUND
Fatigue is one of the most common subjective symptom,due to lack of objective diagnostic criteria ,it is often neglected,especially in the early ...
Femtosecond Laser Machining At Submicron And Nano Scale
Femtosecond Laser Machining At Submicron And Nano Scale
The arrival of the femtosecond laser with a MHz repetition rate has provided the industry with a new tool to conduct submicron and nano scale machining. Several advantages such as ...
Femtosecond Laser Machining At Submicron And Nano Scale
Femtosecond Laser Machining At Submicron And Nano Scale
The arrival of the femtosecond laser with a MHz repetition rate has provided the industry with a new tool to conduct submicron and nano scale machining. Several advantages such as ...
Dual-parameter sensing based on symmetrically chirped long-period fiber grating
Dual-parameter sensing based on symmetrically chirped long-period fiber grating
<sec>A dual-parameter sensor based on a symmetrically chirped long-period fiber grating (SCLPFG) is proposed and demonstrated. The SCLPFG consists of two segments of long-per...