The Nucleus Contour Electrode Array: An Electrophysiological Study
View through CrossRef
AbstractObjective/Hypothesis Positioning intracochlear electrodes adjacent to the modiolus would lead to a reduction in threshold levels and latencies, as measured with electrically evoked auditory brainstems responses. Recently, Cochlear Corporation introduced a new perimodiolar array (Contour electrode) characterized by a platinum stylet inserted into the array's silicone carrier that keeps the electrode in a straightened configuration before insertion. After completion of the insertion, the withdrawal of the stylet allows the array to coil within the cochlea positioning electrodes closer to the modiolus. The purpose of the study was to analyze the stimulation properties of the Contour electrode by evaluating the effects of the withdrawal of the stylet on electrical auditory brainstem response (EABR) characteristics.Methods Electrical auditory brainstem response registrations were performed intraoperatively on three electrodes (1 apical, 1 medial, 1 basal) before and after the removal of the stylet in 10 patients implanted with the Nucleus 24 Contour device. A within‐patient comparison of EABR characteristics was performed. The Student t test was used to assess differences in EABR measures obtained before and after the stylet removal.Results Mean EABR thresholds were significantly lower after the removal of the stylet than with the stylet in situ for all three electrodes tested. After the removal of the stylet, latencies of waves III and V significantly decreased, whereas amplitudes significantly increased.Conclusion Reduction in EABR threshold levels and latencies as well as an increase in waves III and V amplitudes after the stylet removal all demonstrate the effectiveness of the Contour system in positioning intracochlear electrodes closer to auditory neurons.
Title: The Nucleus Contour Electrode Array: An Electrophysiological Study
Description:
AbstractObjective/Hypothesis Positioning intracochlear electrodes adjacent to the modiolus would lead to a reduction in threshold levels and latencies, as measured with electrically evoked auditory brainstems responses.
Recently, Cochlear Corporation introduced a new perimodiolar array (Contour electrode) characterized by a platinum stylet inserted into the array's silicone carrier that keeps the electrode in a straightened configuration before insertion.
After completion of the insertion, the withdrawal of the stylet allows the array to coil within the cochlea positioning electrodes closer to the modiolus.
The purpose of the study was to analyze the stimulation properties of the Contour electrode by evaluating the effects of the withdrawal of the stylet on electrical auditory brainstem response (EABR) characteristics.
Methods Electrical auditory brainstem response registrations were performed intraoperatively on three electrodes (1 apical, 1 medial, 1 basal) before and after the removal of the stylet in 10 patients implanted with the Nucleus 24 Contour device.
A within‐patient comparison of EABR characteristics was performed.
The Student t test was used to assess differences in EABR measures obtained before and after the stylet removal.
Results Mean EABR thresholds were significantly lower after the removal of the stylet than with the stylet in situ for all three electrodes tested.
After the removal of the stylet, latencies of waves III and V significantly decreased, whereas amplitudes significantly increased.
Conclusion Reduction in EABR threshold levels and latencies as well as an increase in waves III and V amplitudes after the stylet removal all demonstrate the effectiveness of the Contour system in positioning intracochlear electrodes closer to auditory neurons.
Related Results
Hu similarity coefficient: a clinically oriented metric to evaluate contour accuracy in radiation therapy
Hu similarity coefficient: a clinically oriented metric to evaluate contour accuracy in radiation therapy
Abstract
To propose a clinically oriented quantitative metric, Hu similarity coefficient (HSC), to evaluate contour quality, gauge the performance of auto contour...
Boosting Oxygen Electrode Performance via a Redox-Treatment
Boosting Oxygen Electrode Performance via a Redox-Treatment
Introduction
The transition to a sustainable energy system complying with climate policy targets is a huge societal challenge. “Hard to electri...
HU Coefficient: A Clinically Oriented Metric to Evaluate Contour Accuracy in Radiation Therapy
HU Coefficient: A Clinically Oriented Metric to Evaluate Contour Accuracy in Radiation Therapy
Abstract
Purpose
To propose a clinically oriented quantitative metric, the HU coefficient, to evaluate contour quality, gauge the performance of auto contouring methods, a...
Supercapacitive MnO2/PEDOT: PSS Modified 3D-Printed Polymeric Micro-Pillar Electrode for Extraction of Photosynthetic Electrons
Supercapacitive MnO2/PEDOT: PSS Modified 3D-Printed Polymeric Micro-Pillar Electrode for Extraction of Photosynthetic Electrons
Photosynthetic bio-electrochemical cells (PBECs) have been reported as having promising potential for the renewable energy field. When photosynthesis occurs, photosynthetic electro...
Modelling the role of contour integration in visual inference
Modelling the role of contour integration in visual inference
Abstract
Under difficult viewing conditions, the brain’s visual system uses a variety of recurrent modulatory mechanisms to augment feed-forward processing. One res...
Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method
Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method
OBJECTIVES: Cochlear-implant companies manufacture devices with different electrode array types. Some arrays have a straight geometry designed for minimal neuronal trauma, while ot...
Cycling Behavior of Iron Electrodes in Alkaline Batteries
Cycling Behavior of Iron Electrodes in Alkaline Batteries
Iron based alkaline battery systems such as nickel-iron and iron-air batteries are very attractive candidates for grid-scale energy storage applications [1]. Iron, which is the pri...
Percolation Investigation of Polymer-Based Battery Electrodes and Its Influence on Capacity Utilization
Percolation Investigation of Polymer-Based Battery Electrodes and Its Influence on Capacity Utilization
Our oral presentation will offer a comprehensive exploration of the intricate dynamics governing organic radical battery electrodes, focusing on the percolation phenomena and its c...