The Nuclear Magnetic Flowmeter for Monitoring the Consumption and Composition of Oil and Its Complex Mixtures in Real-Time
View through CrossRef
The necessity of increasing the efficiency of primary oil purification in a drilling station or an offshore platform has been substantiated. We consider the problems that arise during the primary processing of oil mixtures. Important conditions for increasing the efficiency of primary purification (separation) of oil mixtures include measuring the consumption and determining the content of various impurities (water, undissolved particles) and air in them, with an error of no more than 2%. We analyzed the possibilities of using various designs of flowmeters to measure the consumption of the oil mixture coming from a well. It is also necessary to use other measuring instruments to control the state of this mixture, which creates additional problems (searching for an appropriate locations to place them, providing the required operating conditions). Various designs of nuclear magnetic flowmeters–relaxometers were considered, making it possible to measure the consumption of a liquid medium and its times of longitudinal T1 and transverse T2 relaxation with one device. The measured values of T1 and T2 determine the state of the medium. The design of the industrial nuclear magnetic flowmeter–relaxometer M-Phase 5000, which is used to control the flow and quality of oil and oil products, was considered in more detail. Problems were identified that did not allow using this design of a nuclear magnetic flowmeter–relaxometer in a drilling rig or offshore platform. A new design of a nuclear magnetic flowmeter–relaxometer was developed, implementing the methods for measuring q, T1, and T2. These methods and various technical solutions make it possible to use this device at a drilling station or offshore platform. The measurement errors of the consumption q, T1, and T2 were determined. The results of various media studies are presented and compared with q, T1, and T2 measurements on other devices and measured volume (to confirm the adequacy of q measurements). The application scopes of the developed nuclear magnetic flowmeter–relaxometer were determined, in addition to the systems of primary oil processing.
Title: The Nuclear Magnetic Flowmeter for Monitoring the Consumption and Composition of Oil and Its Complex Mixtures in Real-Time
Description:
The necessity of increasing the efficiency of primary oil purification in a drilling station or an offshore platform has been substantiated.
We consider the problems that arise during the primary processing of oil mixtures.
Important conditions for increasing the efficiency of primary purification (separation) of oil mixtures include measuring the consumption and determining the content of various impurities (water, undissolved particles) and air in them, with an error of no more than 2%.
We analyzed the possibilities of using various designs of flowmeters to measure the consumption of the oil mixture coming from a well.
It is also necessary to use other measuring instruments to control the state of this mixture, which creates additional problems (searching for an appropriate locations to place them, providing the required operating conditions).
Various designs of nuclear magnetic flowmeters–relaxometers were considered, making it possible to measure the consumption of a liquid medium and its times of longitudinal T1 and transverse T2 relaxation with one device.
The measured values of T1 and T2 determine the state of the medium.
The design of the industrial nuclear magnetic flowmeter–relaxometer M-Phase 5000, which is used to control the flow and quality of oil and oil products, was considered in more detail.
Problems were identified that did not allow using this design of a nuclear magnetic flowmeter–relaxometer in a drilling rig or offshore platform.
A new design of a nuclear magnetic flowmeter–relaxometer was developed, implementing the methods for measuring q, T1, and T2.
These methods and various technical solutions make it possible to use this device at a drilling station or offshore platform.
The measurement errors of the consumption q, T1, and T2 were determined.
The results of various media studies are presented and compared with q, T1, and T2 measurements on other devices and measured volume (to confirm the adequacy of q measurements).
The application scopes of the developed nuclear magnetic flowmeter–relaxometer were determined, in addition to the systems of primary oil processing.
Related Results
The Multifunctional Nuclear Magnetic Flowmeter for Control to the Consumption and Condition of Coolant in Nuclear Reactors
The Multifunctional Nuclear Magnetic Flowmeter for Control to the Consumption and Condition of Coolant in Nuclear Reactors
The necessity of coolant flow consumption measurement accuracy increase in the nuclear reactor primary circuit has been substantiated. Additionally, the need to control the coolant...
Swing-Rod Flowmeter - A New Downhole Flow Measurement Technology
Swing-Rod Flowmeter - A New Downhole Flow Measurement Technology
Abstract
In the process of separate layer injection and production, downhole flow measurement is always a difficult problem and is the bottleneck for realizing flow ...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
ABSTRACTOn a global and regional scale, Indonesia has one of the least environmentally sustainable economies in the Asia-Pacific region. Consumption is one of the key factors contr...
Method of liquid consumption measuring in nuclear magnetic flowmeters-relaxometers
Method of liquid consumption measuring in nuclear magnetic flowmeters-relaxometers
The need to expand the functionality of systems for monitoring the parameters of the flow of liquid media is substantiated. The advantages of using meters based on the phenomenon o...
The Optimization Application and Reserch of Electric Submersible Progressing Cavity Pump in Heavy Oil and Highly Deviated Wells
The Optimization Application and Reserch of Electric Submersible Progressing Cavity Pump in Heavy Oil and Highly Deviated Wells
Abstract
There are various types of reservoirs in Dagang oilfield, in which the geological reserves of heavy oil reservoirs account for 43.1% of the total geological...
Is the nuclear attraction just magnetic moment interaction between nucleons?
Is the nuclear attraction just magnetic moment interaction between nucleons?
Abstract
By reexamining the magnetic moment interaction between nucleons, it is argued in this article that the formula for calculating magnetic induction generated by magn...
Study on Nuclear Safety Management Based on Multiple Nuclear Power Plants Experience Feedback Management
Study on Nuclear Safety Management Based on Multiple Nuclear Power Plants Experience Feedback Management
Abstract
Nuclear power plant experience feedback management includes event reporting, screening, analysis, corrective action management and assessment. In the early ...