Background: Distal femur fractures pose significant treatment challenges due to their anatomical complexity and varied injury mechanisms. Locking compression plates (LCPs) have emerged as a favorable fixation method, particularly for complex and osteoporotic fractures. Despite global advancements, limited local data exist on the functional outcomes following LCP fixation in the regional population.
Objective: To determine the functional outcome in patients with distal femur fractures treated with locking compression plates using Neer’s scoring system.
Methods: This descriptive study was conducted over six months at the Department of Orthopedics, Khyber Teaching Hospital, Peshawar. A total of 152 patients aged 18–60 years with AO type A or C distal femur fractures were included. Exclusion criteria were open wounds, pathological fractures, peri-prosthetic fractures, delayed presentations, and significant comorbidities. Surgical fixation was performed using the Swashbuckler approach, followed by individualized rehabilitation protocols. Functional outcomes were assessed four weeks postoperatively using Neer’s criteria. Data were analyzed using SPSS version 25.
Results: Among 152 patients, the mean age was 38.6 ± 11.5 years; 63.8% were male. Right-sided fractures were more common (56.6%). Type A fractures slightly outnumbered type C (50.7% vs. 49.3%). Neer’s score showed excellent outcomes in 55.9% of cases, good in 29.6%, fair in 13.2%, and poor in 1.3%. Type A fractures showed superior results compared to type C. No major intraoperative complications were reported.
Conclusion: LCP fixation for distal femur fractures yields promising early functional outcomes, particularly in type A fractures. It supports early mobilization, anatomical alignment, and satisfactory recovery, reinforcing its role as a preferred surgical modality in such injuries.
Health and Research Insights
Title: FUNCTIONAL OUTCOME IN PATIENTS WITH DISTAL FEMUR FRACTURE TREATED WITH LOCKING COMPRESSION PLATE
Description:
Background: Distal femur fractures pose significant treatment challenges due to their anatomical complexity and varied injury mechanisms.
Locking compression plates (LCPs) have emerged as a favorable fixation method, particularly for complex and osteoporotic fractures.
Despite global advancements, limited local data exist on the functional outcomes following LCP fixation in the regional population.
Objective: To determine the functional outcome in patients with distal femur fractures treated with locking compression plates using Neer’s scoring system.
Methods: This descriptive study was conducted over six months at the Department of Orthopedics, Khyber Teaching Hospital, Peshawar.
A total of 152 patients aged 18–60 years with AO type A or C distal femur fractures were included.
Exclusion criteria were open wounds, pathological fractures, peri-prosthetic fractures, delayed presentations, and significant comorbidities.
Surgical fixation was performed using the Swashbuckler approach, followed by individualized rehabilitation protocols.
Functional outcomes were assessed four weeks postoperatively using Neer’s criteria.
Data were analyzed using SPSS version 25.
Results: Among 152 patients, the mean age was 38.
6 ± 11.
5 years; 63.
8% were male.
Right-sided fractures were more common (56.
6%).
Type A fractures slightly outnumbered type C (50.
7% vs.
49.
3%).
Neer’s score showed excellent outcomes in 55.
9% of cases, good in 29.
6%, fair in 13.
2%, and poor in 1.
3%.
Type A fractures showed superior results compared to type C.
No major intraoperative complications were reported.
Conclusion: LCP fixation for distal femur fractures yields promising early functional outcomes, particularly in type A fractures.
It supports early mobilization, anatomical alignment, and satisfactory recovery, reinforcing its role as a preferred surgical modality in such injuries.
Related Results
Comparative study of operative treatment of distal femur fractures using retrograde intramedullary nail versus locking plate; Retrospective study
Comparative study of operative treatment of distal femur fractures using retrograde intramedullary nail versus locking plate; Retrospective study
Introduction: The overall incidence of distal femur fractures is approximately 37 per 100,000 person-years.1 These fractures are either caused by high energy trauma in younger grou...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
Outcome of a Nail-plate Fixation Combination for a Distal Femur Fracture in a 99-year-old Patient
Outcome of a Nail-plate Fixation Combination for a Distal Femur Fracture in a 99-year-old Patient
Introduction: This report describes the use of a combination of a retrograde femoral nail and distal femur locking plate for the treatment of an open intra-articular distal femur f...
MANAGEMENT OF DISTAL FEMUR FRACTURES IN ADULT WITH LOCKING COMPRESSION PLATE
MANAGEMENT OF DISTAL FEMUR FRACTURES IN ADULT WITH LOCKING COMPRESSION PLATE
Objective: To evaluate the clinical outcomes and radiological union of distal third femur fractures by using distal femur locking plate, in Zagazig university hospitals and KafrSaa...
Functional and Radiological Outcomes after Locking Compression Plate Fixation of Adult Distal Femur Fractures: A Prospective Observational Study
Functional and Radiological Outcomes after Locking Compression Plate Fixation of Adult Distal Femur Fractures: A Prospective Observational Study
Abstract
Background:
Distal femoral fractures remain challenging injuries because stable fixation must be combined with a...
Risk factors, classification, and operative choices of femur fractures at a Tertiary Hospital: first report from Somalia
Risk factors, classification, and operative choices of femur fractures at a Tertiary Hospital: first report from Somalia
AbstractA traumatic femur fracture is a significant cause of morbidity, affecting one to three million individuals annually. The present is the first study investigated the epidemi...
Comparison of Dynamic and Locking Compression Plates in Humeral Shaft Fractures
Comparison of Dynamic and Locking Compression Plates in Humeral Shaft Fractures
Objectives: To compare the functional outcome of shoulder in humeral shaft fractures fixed with dynamic compression plate versus locking compression plate. Design: This was an RCT ...
Role of Distal Femur Anatomical Plate in Fracture of Distal Femur
Role of Distal Femur Anatomical Plate in Fracture of Distal Femur
Introduction: Distal femur fractures are mostly caused due to vehicular injuries in the middle-aged population. Operative treatment has been preferred with open reduction and inter...