Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Influence of ocular biometry on peripheral retinal visualization: A comparative study of Clarus and Optos widefield imaging systems

View through CrossRef
Abstract Background The purpose was to compare the Clarus 500 and Optos Daytona widefield imaging systems with respect to the farthest clinically assessable peripheral retinal structure in each quadrant, and to evaluate whether ocular biometry, particularly axial length and spherical equivalent, influences device specific widefield performance. Methods Twenty-six eyes underwent same day widefield imaging with Clarus 500 (Zeiss Meditec AG, Jena, Germany) and Optos Daytona (Optos plc, Dunfermline, UK). For each quadrant, the most peripheral anatomically interpretable structure was identified, and device differences were analyzed using McNemar tests. Associations with axial length and spherical equivalent, were evaluated using Mann-Whitney U tests and univariate and multivariate logistic regression. Receiver operating characteristic analysis was performed to assess the predictive value of axial length and to determine the optimal cutoff for device superiority. Results Both widefield systems showed similar performance in the superior temporal, inferior temporal, and inferior nasal quadrants with no statistically significant differences. In the superior nasal quadrant, however, eyes in which Clarus reached farther had significantly longer axial length (23.97 ± 1.62 mm versus 22.53 ± 0.94 mm, p = 0.016) and a more myopic spherical equivalent (− 2.05 ± 4.52 D versus + 2.69 ± 2.56 D, p = 0.019). Axial length significantly predicted Clarus superiority in univariate regression (odds ratio 2.39, p = 0.033). Receiver operating characteristic analysis demonstrated good discriminatory ability of axial length with an area under the curve of 0.782 and an optimal cutoff of 23.77 mm. Shorter and hyperopic eyes showed a tendency toward greater peripheral reach with Optos, although this trend did not achieve statistical significance. Conclusion The Clarus 500 and Optos Daytona provide comparable peripheral visualization in most retinal quadrants. Device differences become apparent in the superior nasal quadrant, where axial elongation and myopic ocular geometry enhance Clarus performance, while no statistically supported advantage for Optos is observed in shorter or hyperopic eyes. These findings underscore the relevance of ocular biometry in widefield retinal imaging and support individualized device selection in patients with myopic anatomy. Overall, both devices demonstrated robust and reliable performance, providing high quality widefield imaging suitable for comprehensive peripheral retinal assessment.
Title: Influence of ocular biometry on peripheral retinal visualization: A comparative study of Clarus and Optos widefield imaging systems
Description:
Abstract Background The purpose was to compare the Clarus 500 and Optos Daytona widefield imaging systems with respect to the farthest clinically assessable peripheral retinal structure in each quadrant, and to evaluate whether ocular biometry, particularly axial length and spherical equivalent, influences device specific widefield performance.
Methods Twenty-six eyes underwent same day widefield imaging with Clarus 500 (Zeiss Meditec AG, Jena, Germany) and Optos Daytona (Optos plc, Dunfermline, UK).
For each quadrant, the most peripheral anatomically interpretable structure was identified, and device differences were analyzed using McNemar tests.
Associations with axial length and spherical equivalent, were evaluated using Mann-Whitney U tests and univariate and multivariate logistic regression.
Receiver operating characteristic analysis was performed to assess the predictive value of axial length and to determine the optimal cutoff for device superiority.
Results Both widefield systems showed similar performance in the superior temporal, inferior temporal, and inferior nasal quadrants with no statistically significant differences.
In the superior nasal quadrant, however, eyes in which Clarus reached farther had significantly longer axial length (23.
97 ± 1.
62 mm versus 22.
53 ± 0.
94 mm, p = 0.
016) and a more myopic spherical equivalent (− 2.
05 ± 4.
52 D versus + 2.
69 ± 2.
56 D, p = 0.
019).
Axial length significantly predicted Clarus superiority in univariate regression (odds ratio 2.
39, p = 0.
033).
Receiver operating characteristic analysis demonstrated good discriminatory ability of axial length with an area under the curve of 0.
782 and an optimal cutoff of 23.
77 mm.
Shorter and hyperopic eyes showed a tendency toward greater peripheral reach with Optos, although this trend did not achieve statistical significance.
Conclusion The Clarus 500 and Optos Daytona provide comparable peripheral visualization in most retinal quadrants.
Device differences become apparent in the superior nasal quadrant, where axial elongation and myopic ocular geometry enhance Clarus performance, while no statistically supported advantage for Optos is observed in shorter or hyperopic eyes.
These findings underscore the relevance of ocular biometry in widefield retinal imaging and support individualized device selection in patients with myopic anatomy.
Overall, both devices demonstrated robust and reliable performance, providing high quality widefield imaging suitable for comprehensive peripheral retinal assessment.

Related Results

Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Prevalence of peripheral retinal findings in retinal patients using ultra-widefield pseudocolor fundus imaging
Prevalence of peripheral retinal findings in retinal patients using ultra-widefield pseudocolor fundus imaging
AbstractUltra-widefield retinal imaging is increasingly used in ophthalmology and optometry practices to image patients identifying peripheral abnormalities. However, the clinical ...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Inoculation with arbuscular mycorrhizal fungus Rhizophagus clarus on tomato promotes increasing yield under organic farming inputs
Inoculation with arbuscular mycorrhizal fungus Rhizophagus clarus on tomato promotes increasing yield under organic farming inputs
ABSTRACT: Organic agriculture comprises farming practices that discard synthetic pesticides and fertilizers. Tomato production demands huge amounts of fertilizers and pesticides. I...
Composing the puzzle: a case of acute unilateral vision loss
Composing the puzzle: a case of acute unilateral vision loss
A 75‐year‐old Caucasian male, with a medical history of hypertension, diabetes, and dyslipidemia, presented to the emergency department with sudden complete vision loss in his left...

Back to Top