Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Study on thermal insulation of liquefied natural gas cryogenic road tanker

View through CrossRef
The tanks designed for liquefied natural gas transport must be thermally insulated from the environment due to the low condensing temperature of the gas. The effectiveness of thermal insulation significantly affects the tank's operating parameters and its operating costs. As there is no perfect insulation, there is a need for analyses that would determine its suitability in specific applications. In this paper the issue of heat transfer through double-walled cryogenic tanks with evacuated insulation system was discussed. Afterwards the study of insulation variants of liquefied natural gas cryogenic road tanker was presented. The use of several layers of insulation made of modern and efficient materials such as aero-gel and fiberglass or the use of multi-layer isolation has been considered and compared to the use of perlite powder. The heat flux through insulation systems was tested for different variants of evacuated insulation under residual gas pressure of 10-1 Pa, 10-3 Pa, and 100 kPa. Finally, for selected insulation variants, the heat leakage was tested for 50 m3 liquefied natural gas road tanker. The investigation of heat-flow for the transient thermal analysis was performed by applying finite element method. The aim of the study was to determine the variant of insulation system with the relatively low heat leakage to the tank and low cost of materials and vacuum production.
Title: Study on thermal insulation of liquefied natural gas cryogenic road tanker
Description:
The tanks designed for liquefied natural gas transport must be thermally insulated from the environment due to the low condensing temperature of the gas.
The effectiveness of thermal insulation significantly affects the tank's operating parameters and its operating costs.
As there is no perfect insulation, there is a need for analyses that would determine its suitability in specific applications.
In this paper the issue of heat transfer through double-walled cryogenic tanks with evacuated insulation system was discussed.
Afterwards the study of insulation variants of liquefied natural gas cryogenic road tanker was presented.
The use of several layers of insulation made of modern and efficient materials such as aero-gel and fiberglass or the use of multi-layer isolation has been considered and compared to the use of perlite powder.
The heat flux through insulation systems was tested for different variants of evacuated insulation under residual gas pressure of 10-1 Pa, 10-3 Pa, and 100 kPa.
Finally, for selected insulation variants, the heat leakage was tested for 50 m3 liquefied natural gas road tanker.
The investigation of heat-flow for the transient thermal analysis was performed by applying finite element method.
The aim of the study was to determine the variant of insulation system with the relatively low heat leakage to the tank and low cost of materials and vacuum production.

Related Results

The Burden of Road Traffic Injuries: A Global Perspective
The Burden of Road Traffic Injuries: A Global Perspective
Introduction     Road Traffic Injury (RTI) pose a significant health challenge. It represents the eighth leading cause of death globally, prompting the UN to designate 2011-2020 as...
Transportation Distribution Analysis to Reduce Carbon Emissions
Transportation Distribution Analysis to Reduce Carbon Emissions
This study aims to investigate the role of PT. TBBM Tanker Car transportation distribution in distributing fuel oil with its tree logic in realizing a green energy system. The prim...
Thermal Performance and Building Energy Simulation of Precast Insulation Walls in Two Climate Zones
Thermal Performance and Building Energy Simulation of Precast Insulation Walls in Two Climate Zones
Traditional concrete buildings exhibit low energy consumption and high heat loss, which results in a larger environmental problem. Precast insulation walls are proposed for strengt...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Computation Model on a Chain-Turret-Moored Tanker in Irregular Seas
Computation Model on a Chain-Turret-Moored Tanker in Irregular Seas
Abstract To compute the low frequency mooring forces of, for instance, a turret moored storage/production tanker exposed to survival conditions the hydrodynamic e...
Low-Frequency Motions of Tankers on Tandem Offloading Condition
Low-Frequency Motions of Tankers on Tandem Offloading Condition
ABSTRACT In this paper a number of hydrodynamic aspects of tandem mooring operations of floating VLCCS will be discussed. The effect of shielding of the wind and ...
Manager Of Supply Planning And Projects
Manager Of Supply Planning And Projects
Abstract The Southern California Gas Company is responsible for providing gas service to 12 million southern Californians. SoCal Gas, like other major gas distrib...
A Cost Effective Analysis of Nigerian LNG
A Cost Effective Analysis of Nigerian LNG
Abstract Nigeria is the latest entrant in the world LNG market. This paper evaluates the economics of Nigerian LNG in light of prevailing trends in the supply, de...

Back to Top