Javascript must be enabled to continue!
Minimally Sufficient Experimental Design using Identifiability Analysis
View through CrossRef
ABSTRACTMathematical models are increasingly being developed and calibrated in tandem with data collection, empowering scientists to intervene in real time based on quantitative model predictions. Well-designed experiments can help augment the predictive power of a mathematical model but the question of when to collect data to maximize its utility for a model is non-trivial. Here we define data as model-informative if it results in a unique parametrization, assessed through the lens of practical identifiability. The framework we propose identifies an optimal experimental design (how much data to collect and when to collect it) that ensures parameter identifiability (permitting confidence in model predictions), while minimizing experimental time and costs. We demonstrate the power of the method by applying it to a modified version of a classic site-of-action pharmacokinetic/pharmacodynamic model that describes distribution of a drug into the tumor microenvironment (TME), where its efficacy is dependent on the level of target occupancy in the TME. In this context, we identify a minimal set of time points when data needs to be collected that robustly ensures practical identifiability of model parameters. The proposed methodology can be applied broadly to any mathematical model, allowing for the identification of a minimally sufficient experimental design that collects the most informative data.
Title: Minimally Sufficient Experimental Design using Identifiability Analysis
Description:
ABSTRACTMathematical models are increasingly being developed and calibrated in tandem with data collection, empowering scientists to intervene in real time based on quantitative model predictions.
Well-designed experiments can help augment the predictive power of a mathematical model but the question of when to collect data to maximize its utility for a model is non-trivial.
Here we define data as model-informative if it results in a unique parametrization, assessed through the lens of practical identifiability.
The framework we propose identifies an optimal experimental design (how much data to collect and when to collect it) that ensures parameter identifiability (permitting confidence in model predictions), while minimizing experimental time and costs.
We demonstrate the power of the method by applying it to a modified version of a classic site-of-action pharmacokinetic/pharmacodynamic model that describes distribution of a drug into the tumor microenvironment (TME), where its efficacy is dependent on the level of target occupancy in the TME.
In this context, we identify a minimal set of time points when data needs to be collected that robustly ensures practical identifiability of model parameters.
The proposed methodology can be applied broadly to any mathematical model, allowing for the identification of a minimally sufficient experimental design that collects the most informative data.
Related Results
A new method for a priori practical identifiability
A new method for a priori practical identifiability
Abstract
Background and objective
Practical identifiability analysis – to determine whether a model property can be determined ...
ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
Minimally invasive surgery has revolutionized the treatment of various medical conditions, offering significant benefits in terms of recovery and fewer complications. In the field ...
Identifiability analysis in conceptual sewer modelling
Identifiability analysis in conceptual sewer modelling
For a sufficient calibration of an environmental model not only parameter sensitivity but also parameter identifiability is an important issue. In identifiability analysis it is po...
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
Abstract
Background
Minimally invasive technique for esophagectomy has emerged as the standard of care for resectable esophageal...
Making predictions using poorly identified mathematical models
Making predictions using poorly identified mathematical models
Abstract
Many commonly used mathematical models in the field of mathematical biology involve challenges of parameter non-identifiability. Practic...
Oncological outcomes in minimally invasive gastric cancer surgery
Oncological outcomes in minimally invasive gastric cancer surgery
In the first part of this dissertation an assessment was made on current available
evidence regarding outcomes in minimally invasive gastrectomy in comparison to open
gastrectomy. ...
Fuzheng Xiaoliu granules reduce the 2-year recurrence rate of early-stage hepatitis B virus-related hepatocellular carcinoma after comprehensive minimally invasive surgery: a study protocol for a prospective, multicenter, central randomized, double-blind,
Fuzheng Xiaoliu granules reduce the 2-year recurrence rate of early-stage hepatitis B virus-related hepatocellular carcinoma after comprehensive minimally invasive surgery: a study protocol for a prospective, multicenter, central randomized, double-blind,
Abstract
Background: Hepatitis B virus (HBV) infection is one of the most common risk factors for hepatocellular carcinoma (HCC). With the continuous improvement of minimal...

