Javascript must be enabled to continue!
Use of Small Specimens for Evaluation of Irradiated Materials
View through CrossRef
Small specimens are playing the key role in evaluating properties of irradiated materials. The use of small specimens provides several advantages. Typically, only small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose. Small volume of irradiated material may also allow for easier handling of specimens. Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal. However, use of small specimens imposes variety of challenges as well. These challenges are associated with proper accounting for size effects and transferability of small specimen data to the real structures of interest. The PCVN specimen as well as any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of RPVs. The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs. Precracking and testing of Charpy surveillance specimens would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data. However, there is a growing number of indications that there might be a bias in the reference fracture toughness transition temperature, To values derived from PCVN and compact specimens. The present paper summarizes data from the series of experiments that use subsize specimens for evaluation of the transition fracture toughness of reactor pressure vessel (RPV) steels. Two types of compact specimens and three types of three-point bend specimens from five RPV materials were used in these subsize experiments. The current results showed that To determined from PCVN specimens with width (W) to thickness (B) ratio W/B = 1, on average, are lower than To determined from compact specimens with W/B = 2. At the same time, three-point bend specimens with W/B = 2 exhibited To values that were very similar to To values derived from compact specimens. Constraint corrections developed by Dodds et al. are applied to assess the bias.
American Society of Mechanical Engineers
Title: Use of Small Specimens for Evaluation of Irradiated Materials
Description:
Small specimens are playing the key role in evaluating properties of irradiated materials.
The use of small specimens provides several advantages.
Typically, only small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose.
Small volume of irradiated material may also allow for easier handling of specimens.
Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal.
However, use of small specimens imposes variety of challenges as well.
These challenges are associated with proper accounting for size effects and transferability of small specimen data to the real structures of interest.
The PCVN specimen as well as any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of RPVs.
The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs.
Precracking and testing of Charpy surveillance specimens would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data.
However, there is a growing number of indications that there might be a bias in the reference fracture toughness transition temperature, To values derived from PCVN and compact specimens.
The present paper summarizes data from the series of experiments that use subsize specimens for evaluation of the transition fracture toughness of reactor pressure vessel (RPV) steels.
Two types of compact specimens and three types of three-point bend specimens from five RPV materials were used in these subsize experiments.
The current results showed that To determined from PCVN specimens with width (W) to thickness (B) ratio W/B = 1, on average, are lower than To determined from compact specimens with W/B = 2.
At the same time, three-point bend specimens with W/B = 2 exhibited To values that were very similar to To values derived from compact specimens.
Constraint corrections developed by Dodds et al.
are applied to assess the bias.
Related Results
Structure and Properties of PA66/Irradiated LLDPE Blends
Structure and Properties of PA66/Irradiated LLDPE Blends
The oxygen-containing groups such as C—O, C=O, and C(=O)O were introduced onto linear low density polyethylene (LLDPE) chains by ultraviolet irradiation in air. The irradiated LLDP...
The Master Curve Fracture Toughness Evaluation of Irradiated Plate Material JRQ Using Miniature-C(T) Specimens
The Master Curve Fracture Toughness Evaluation of Irradiated Plate Material JRQ Using Miniature-C(T) Specimens
The Master Curve approach is a powerful tool to evaluate material-specific fracture toughness of ferritic steels, such as RPV steels, using a limited number of specimens. However, ...
An ultrasonographic evaluation of skin thickness in breast cancer patients after postmastectomy radiation therapy
An ultrasonographic evaluation of skin thickness in breast cancer patients after postmastectomy radiation therapy
Abstract
Background
To determine the usefulness of ultrasonography in the assessment of post radiotherapy skin changes in postmastectomy breast c...
Rejuvenation of irradiated AS‐1 red cells
Rejuvenation of irradiated AS‐1 red cells
BACKGROUND: Gamma irradiation of blood components is used to prevent transfusion‐associated graft‐versus‐host disease. The demand for irradiated blood components is increasing beca...
The irradiated human mandible
The irradiated human mandible
Mandibular bone is known to be susceptible to irradiation damage, especially when radiation dose exceeds 50 Gy. This can result in compromised wound healing and ultimately osteorad...
Anastomotic Blood-Flow Reduction in Rat Small Intestine with Chronic Radiation Damage
Anastomotic Blood-Flow Reduction in Rat Small Intestine with Chronic Radiation Damage
<b>Background/Aims: </b>Anastomoses in previously irradiated intestine are prone to leakage, possibly due to an impeded blood supply. Whether or not chronic radiation d...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract
The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Immunogenicity and protective efficacy of irradiated Salmonella Gallinarum against homologous challenge infection in Bovans brown chickens
Immunogenicity and protective efficacy of irradiated Salmonella Gallinarum against homologous challenge infection in Bovans brown chickens
Fowl typhoid is a systemic poultry disease caused by Salmonella Gallinarum (SG). It is responsible for significant economic loss, due to its severe morbidity and mortality. An irr...

