Javascript must be enabled to continue!
Development of Smart Meter to Monitor Real Time Energy Consumption for Sustainability
View through CrossRef
This study constructed a Smart Energy Meter where energy consumption can be viewed by the consumers based on rreal time using data from smart meters. Its goals are to increase productivity, make readings more precise, and take less time to determine an individual residence's energy consumption. The device is made up of the PZEM-016 AC Energy Meter, RS-485 UART Serial Converter, NodeMCU ESP8266, Blynk IoT Application, Arduino Uno R3, and LCD Arduino Keypad Module Shield Board. The PZEM-016 is used in this smart energy meter to measure voltage, current, power, frequency, power factor, and energy consumption. Because it lacks its own display, an RS-485 was utilized to communicate with the NodeMCU and Arduino Uno. The NodeMCU sends the parameters to Blynk IoT App as long as it is connected to a fixed mobile WiFi. The Blynk will then display a real-time measurement of the parameters. The Arduino Uno is programmed to display the parameters to the LCD Keypad Module. The device was tested in an actual household. The researchers conducted 48-hour observation on the household where the energy displayed in the Blynk IoT App and the LCD display matches at approximately 9 kWh which is the same as the actual energy meter of the house that is 9kWh. The device is also tested on different appliances which resulted in the same energy consumption in both the Blynk IoT App and LCD display with the ratingsof the appliances. The device was found functional.
Title: Development of Smart Meter to Monitor Real Time Energy Consumption for Sustainability
Description:
This study constructed a Smart Energy Meter where energy consumption can be viewed by the consumers based on rreal time using data from smart meters.
Its goals are to increase productivity, make readings more precise, and take less time to determine an individual residence's energy consumption.
The device is made up of the PZEM-016 AC Energy Meter, RS-485 UART Serial Converter, NodeMCU ESP8266, Blynk IoT Application, Arduino Uno R3, and LCD Arduino Keypad Module Shield Board.
The PZEM-016 is used in this smart energy meter to measure voltage, current, power, frequency, power factor, and energy consumption.
Because it lacks its own display, an RS-485 was utilized to communicate with the NodeMCU and Arduino Uno.
The NodeMCU sends the parameters to Blynk IoT App as long as it is connected to a fixed mobile WiFi.
The Blynk will then display a real-time measurement of the parameters.
The Arduino Uno is programmed to display the parameters to the LCD Keypad Module.
The device was tested in an actual household.
The researchers conducted 48-hour observation on the household where the energy displayed in the Blynk IoT App and the LCD display matches at approximately 9 kWh which is the same as the actual energy meter of the house that is 9kWh.
The device is also tested on different appliances which resulted in the same energy consumption in both the Blynk IoT App and LCD display with the ratingsof the appliances.
The device was found functional.
Related Results
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
ABSTRACTOn a global and regional scale, Indonesia has one of the least environmentally sustainable economies in the Asia-Pacific region. Consumption is one of the key factors contr...
Domestic water meter optimal replacement period to minimize water revenue loss
Domestic water meter optimal replacement period to minimize water revenue loss
Water meter under-registration results in apparent losses and lost revenue for municipalities. Municipalities should scientifically determine the optimal replacement periods for th...
Introducing Optimal Energy Hub Approach in Smart Green Ports based on Machine Learning Methodology
Introducing Optimal Energy Hub Approach in Smart Green Ports based on Machine Learning Methodology
Abstract
The integration of renewable energy systems in port facilities is essential for achieving sustainable and environmentally friendly operations. This paper presents ...
INVESTIGATING THE ROLE OF DATA ANALYTICS IN MONITORING AND MANAGING ENERGY CONSUMPTION IN SMART HOMES, AIMING TO ENHANCE EFFICIENCY AND REDUCE COSTS
INVESTIGATING THE ROLE OF DATA ANALYTICS IN MONITORING AND MANAGING ENERGY CONSUMPTION IN SMART HOMES, AIMING TO ENHANCE EFFICIENCY AND REDUCE COSTS
Smart home technology is progressing rapidly due to the need for better energy management and resulting new potentials for controlling energy. While smart homes use different conne...
Implementation of IOT Based Smart Energy Meter in Oman
Implementation of IOT Based Smart Energy Meter in Oman
Managing the energy efficient and conserving it intelligently for appliances is very much important. On the other side, it may be possible events mistake cause while reading on ene...
Energy Sources and Gross Domestic Product: International Evidence
Energy Sources and Gross Domestic Product: International Evidence
The relationship between energy consumption and economic growth received a significant amount of attention in energy economics literature [Al-Iraiani (2006)]. Rufael (2006) stated ...
Reinventing Smart Water Management System through ICT and IoT Driven Solution for Smart Cities
Reinventing Smart Water Management System through ICT and IoT Driven Solution for Smart Cities
Purpose: Worldwide water scarcity is one of the major problems to deal with. Smart Cities also faces this challenging problem due to its ever-increasing population and limited sour...
Smart Manufacturing Application in Precision Manufacturing
Smart Manufacturing Application in Precision Manufacturing
Industry 4.0 presents an opportunity to gain a competitive advantage through productivity, flexibility, and speed. It also empowers the manufacturing sector to drive the sustainabi...

