Javascript must be enabled to continue!
Simulation and Analysis of Novel Extendable Multilevel Inverter Topology
View through CrossRef
Multilevel inverter (MLI) has become more popular in high power, high voltage industries owing to its high quality output voltage waveform. This paper proposes a novel single phase extendable type MLI topology. The term ‘extendable’ is included since the presented topology can be extended with maximum number of dc voltage sources to synthesize larger output levels. This topology can be operated in both symmetrical and asymmetrical conditions. The major advantages of the proposed inverter topology include minimum switching components, reduced gate driver circuits, less harmonic distortion and reduced switching losses. The comparative analysis based on the number of switches, dc voltage sources and conduction switches between the proposed topology and other existing topologies is presented in this paper. The comparison results show that the proposed inverter topology requires fewer components. The performance of the proposed MLI topology has been analyzed in both symmetrical and asymmetrical conditions. The simulation model is developed using MATLAB/SIMULINK software to verify the performance of the proposed inverter topology and also the feasibility of the presented topology during the symmetrical condition has been validated experimentally.
World Scientific Pub Co Pte Ltd
Title: Simulation and Analysis of Novel Extendable Multilevel Inverter Topology
Description:
Multilevel inverter (MLI) has become more popular in high power, high voltage industries owing to its high quality output voltage waveform.
This paper proposes a novel single phase extendable type MLI topology.
The term ‘extendable’ is included since the presented topology can be extended with maximum number of dc voltage sources to synthesize larger output levels.
This topology can be operated in both symmetrical and asymmetrical conditions.
The major advantages of the proposed inverter topology include minimum switching components, reduced gate driver circuits, less harmonic distortion and reduced switching losses.
The comparative analysis based on the number of switches, dc voltage sources and conduction switches between the proposed topology and other existing topologies is presented in this paper.
The comparison results show that the proposed inverter topology requires fewer components.
The performance of the proposed MLI topology has been analyzed in both symmetrical and asymmetrical conditions.
The simulation model is developed using MATLAB/SIMULINK software to verify the performance of the proposed inverter topology and also the feasibility of the presented topology during the symmetrical condition has been validated experimentally.
Related Results
Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
AbstractThe inverter is considered the core of the PV power plant. The inverter’s failure leads to generation loss and decreases plant availability. So, it is required to investiga...
Modeling of A Single Phase 7-Level Cascaded H-Bridge Multilevel Inverter
Modeling of A Single Phase 7-Level Cascaded H-Bridge Multilevel Inverter
Recently, almost all industrial devices are mostly built on electronic devices which are precisely sensitive to harmonic. In order to meet the requirement from the industries deman...
A Modified Criss-Cross-Based T-Type MLI with Reduced Power Components
A Modified Criss-Cross-Based T-Type MLI with Reduced Power Components
Significant advancements in the field of power electronics have created an ideal opportunity to introduce various topologies of multilevel inverters. These multilevel inverter topo...
A five‐level nested neutral point‐clamped inverter topology
A five‐level nested neutral point‐clamped inverter topology
Abstract
Classical five‐level nested neutral point‐clamped (5L NNPC) inverter‐leg is a hybrid of the flying‐capacitor and diode‐clamped 5‐L inverter‐leg configura...
Three Phase Eleven Level Modular Multilevel Inverter with PD-PWM for Grid Connected System
Three Phase Eleven Level Modular Multilevel Inverter with PD-PWM for Grid Connected System
The prominence of Modular Multilevel Inverters (MMI) is rising owing their merits of simple mechanical
construction and good voltage sharing for semiconductor devices. Mostly Multi...
Design of Control Secheme and Performance Improvement for Multilevel Dc Link Inverter Fed PMBLDC Motor Drive
Design of Control Secheme and Performance Improvement for Multilevel Dc Link Inverter Fed PMBLDC Motor Drive
PMBLDC motors are gaining a lot of popularity due to their high efficiency as the Permanent Magnets do not carry current which results in negligible copper losses as compared to as...
Single-Phase Cascaded Grid Connected Multilevel Inverter for Interfacing Renewable Energy Sources With Microgrid
Single-Phase Cascaded Grid Connected Multilevel Inverter for Interfacing Renewable Energy Sources With Microgrid
In this paper, a novel single-phase cascaded grid connected multilevel inverter (MLI) is proposed for feeding power to microgrid from renewable energy sources (RESs). The proposed ...
Effective Power Utilization Strategy of Fuel Cell System Using FSTP Sepic Inverter
Effective Power Utilization Strategy of Fuel Cell System Using FSTP Sepic Inverter
Four-Switch mode Three-Phase (FSTP) inverter is considered as an advanced inverter structure to diminish the price, complication, dimension and losses during its switching...