Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Double sequential defibrillation: is it ready for prime time?

View through CrossRef
Purpose of review Refractory ventricular fibrillation, which fails to respond to defibrillation, is associated with poor survival. Despite this, there are no treatments that are proven effective beyond standard defibrillation and cardiopulmonary resuscitation. Double sequential external defibrillation (DSED) has been proposed as an alternative defibrillation strategy for this patient population. In this review, we will discuss key evidence surrounding DSED, as we present two opposing arguments, ‘pro’ that DSED is ready for clinical practice and ‘con’ that more research is needed prior to implementation of this technique. Recent findings The Double Sequential External Defibrillation for Refractory Ventricular Fibrillation (DOSE VF) randomized clinical trial demonstrated improved patient outcomes for patients with refractory ventricular fibrillation who did not respond to standard defibrillation attempts. There remain unanswered questions with respect to the mechanism by which DSED may improve outcomes and the logistics of implementation into clinical practice. Summary This article discusses some of the key controversies surrounding DSED and whether this novel defibrillation strategy is ready for integration into standard practice. Further research is ongoing that may help to answer further questions related to the utility of DSED.
Title: Double sequential defibrillation: is it ready for prime time?
Description:
Purpose of review Refractory ventricular fibrillation, which fails to respond to defibrillation, is associated with poor survival.
Despite this, there are no treatments that are proven effective beyond standard defibrillation and cardiopulmonary resuscitation.
Double sequential external defibrillation (DSED) has been proposed as an alternative defibrillation strategy for this patient population.
In this review, we will discuss key evidence surrounding DSED, as we present two opposing arguments, ‘pro’ that DSED is ready for clinical practice and ‘con’ that more research is needed prior to implementation of this technique.
Recent findings The Double Sequential External Defibrillation for Refractory Ventricular Fibrillation (DOSE VF) randomized clinical trial demonstrated improved patient outcomes for patients with refractory ventricular fibrillation who did not respond to standard defibrillation attempts.
There remain unanswered questions with respect to the mechanism by which DSED may improve outcomes and the logistics of implementation into clinical practice.
Summary This article discusses some of the key controversies surrounding DSED and whether this novel defibrillation strategy is ready for integration into standard practice.
Further research is ongoing that may help to answer further questions related to the utility of DSED.

Related Results

CONTINUOUS COMPRESSION WITHOUT DEFIBRILLATION FAVOURED NO SHORT-TERM SURVIVAL IN PROLONGED VENTRICULAR FIBRILLATION
CONTINUOUS COMPRESSION WITHOUT DEFIBRILLATION FAVOURED NO SHORT-TERM SURVIVAL IN PROLONGED VENTRICULAR FIBRILLATION
Objectives Aims: During the 2005 American Heart Association (AHA) Consensus Conference, compression first versus defibrillation first for sudden cardiac arrest wi...
Cost Effectiveness of Defibrillation by Targeted Responders in Public Settings
Cost Effectiveness of Defibrillation by Targeted Responders in Public Settings
Background— Out-of-hospital cardiac arrest is frequent and has poor outcomes. Defibrillation by trained targeted nontraditional responders improves surviva...
Public access defibrillation: challenges and new solutions
Public access defibrillation: challenges and new solutions
Purpose of review The purpose of this article is to review the current status of public access defibrillation and the various utility modalities of early defibrillation...
ONE-SHOCK VERSUS CONTINUOUS DEFIBRILLATION IN AN 8-MIN VENTRICULAR FIBRILLATION CANINE MODEL OF CARDIAC ARREST
ONE-SHOCK VERSUS CONTINUOUS DEFIBRILLATION IN AN 8-MIN VENTRICULAR FIBRILLATION CANINE MODEL OF CARDIAC ARREST
Objectives To investigate the resuscitation effect of a one-shock defibrillation protocol versus conventional continuous defibrillation with treatment variation i...
The incidence of cardiac arrest requiring defibrillation and defibrillation protocols in Australasian hyperbaric units
The incidence of cardiac arrest requiring defibrillation and defibrillation protocols in Australasian hyperbaric units
Introduction: Cardiac arrest (CA) during hyperbaric oxygen treatment (HBOT) is exceedingly rare with only a few cases reported. It is unknown if in-chamber defibrillation of a pati...
‘Power under pressure’ – defibrillation during hyperbaric oxygen therapy: a scoping review
‘Power under pressure’ – defibrillation during hyperbaric oxygen therapy: a scoping review
Introduction: Although defibrillation is the standard treatment for cardiac arrest with shockable rhythms, its safety during hyperbaric oxygen therapy (HBOT) remains uncertain, as ...

Back to Top