Study Design
Retrospective cohort study.
Objective
Limited clinical literature addresses potential differences in fusion features between Oblique lumbar interbody fusion (OLIF) and transforaminal lumbar interbody fusion (TLIF). We observed that in OLIF, there are many cases with the appearance of extra-vertebral bone bridges (EVB), a phenomenon distinct from traditional TLIF fusion. This study aims to compare fusion rates, cage subsidence, and fusion features among OLIF stand-alone (OLIF-SA), OLIF with posterior pedicle screw fixation (OLIF-PS), and TLIF.
Methods
We retrospectively analyzed 198 patients (311 levels) undergoing OLIF-SA, OLIF-PS, or TLIF from July 2017 to June 2021. We assessed patient-reported outcomes, cage subsidence, fusion rate, and fusion features on CT scans.
Results
The study included 64 OLIF-SA patients (102 levels), 60 OLIF-PS patients (99 levels), and 74 TLIF patients (110 levels). Cage settling rates were 33.3% (OLIF-SA), 17.2% (OLIF-PS), and 32.8% (TLIF), with significant differences between OLIF-PS and TLIF (
P
< 0.05). Cage subsidence rates showed no significant difference: 11.8% (OLIF-SA), 9.1% (OLIF-PS), and 12.7% (TLIF) (
P
> 0.05). Fusion rates were 100% (OLIF-SA), 97.0% (OLIF-PS), and 96.4% (TLIF) (
P
= 0.167). Lateral fusion rates significantly differed: 49.0% (OLIF-SA), 30.3% (OLIF-PS), and 10.9% (TLIF) (
P
< 0.001). Preoperative osteophytes strongly promote lateral fusion (
P
< 0.001). VAS and ODI scores improved significantly post-surgery (
P
< 0.01).
Conclusions
OLIF-SA, OLIF-PS, and TLIF surgeries show satisfactory results with comparable fusion rates. Notably, distinctive differences exist in fusion features between OLIF and TLIF surgeries, with lateral fusion more prevalent in OLIF, particularly in OLIF-SA surgeries.
Title: Lateral Fusion is a Unique Feature in Oblique Lumbar Interbody Fusion Surgery: A Retrospective Cohort Study
Description:
Study Design
Retrospective cohort study.
Objective
Limited clinical literature addresses potential differences in fusion features between Oblique lumbar interbody fusion (OLIF) and transforaminal lumbar interbody fusion (TLIF).
We observed that in OLIF, there are many cases with the appearance of extra-vertebral bone bridges (EVB), a phenomenon distinct from traditional TLIF fusion.
This study aims to compare fusion rates, cage subsidence, and fusion features among OLIF stand-alone (OLIF-SA), OLIF with posterior pedicle screw fixation (OLIF-PS), and TLIF.
Methods
We retrospectively analyzed 198 patients (311 levels) undergoing OLIF-SA, OLIF-PS, or TLIF from July 2017 to June 2021.
We assessed patient-reported outcomes, cage subsidence, fusion rate, and fusion features on CT scans.
Results
The study included 64 OLIF-SA patients (102 levels), 60 OLIF-PS patients (99 levels), and 74 TLIF patients (110 levels).
Cage settling rates were 33.
3% (OLIF-SA), 17.
2% (OLIF-PS), and 32.
8% (TLIF), with significant differences between OLIF-PS and TLIF (
P
< 0.
05).
Cage subsidence rates showed no significant difference: 11.
8% (OLIF-SA), 9.
1% (OLIF-PS), and 12.
7% (TLIF) (
P
> 0.
05).
Fusion rates were 100% (OLIF-SA), 97.
0% (OLIF-PS), and 96.
4% (TLIF) (
P
= 0.
167).
Lateral fusion rates significantly differed: 49.
0% (OLIF-SA), 30.
3% (OLIF-PS), and 10.
9% (TLIF) (
P
< 0.
001).
Preoperative osteophytes strongly promote lateral fusion (
P
< 0.
001).
VAS and ODI scores improved significantly post-surgery (
P
< 0.
01).
Conclusions
OLIF-SA, OLIF-PS, and TLIF surgeries show satisfactory results with comparable fusion rates.
Notably, distinctive differences exist in fusion features between OLIF and TLIF surgeries, with lateral fusion more prevalent in OLIF, particularly in OLIF-SA surgeries.
Related Results
Determinants of lateral fusion in single-level oblique lateral lumbar interbody fusion: a retrospective analysis of fusion patterns and clinical outcomes
Determinants of lateral fusion in single-level oblique lateral lumbar interbody fusion: a retrospective analysis of fusion patterns and clinical outcomes
Study Design: Retrospective cohort study.Purpose: This study aimed to (1) determine the incidence of lateral fusion following single-level oblique lateral interbody fusion (OLIF); ...
Minimally Invasive Oblique Lateral Interbody Fusion for L4-5: Surgical Outcomes and Perioperative Complications
Minimally Invasive Oblique Lateral Interbody Fusion for L4-5: Surgical Outcomes and Perioperative Complications
Abstract
Purpose:Oblique lateral interbody fusion is increasingly being used by spine surgeons due to its many advantages. Although clinical analysis of oblique lateral int...
Endoscopic Transforaminal Lumbar Interbody Fusion
Endoscopic Transforaminal Lumbar Interbody Fusion
One of the most common surgical cures for lumbar degenerative illnesses is lumbar fusion. Traditional open lumbar fusion is often used in clinical settings and has positive clinica...
Effect Comparison Of MIS-TLIF Under MED and Quadrant Modes in The Treatment of Lu mbar Spinal Stenosis
Effect Comparison Of MIS-TLIF Under MED and Quadrant Modes in The Treatment of Lu mbar Spinal Stenosis
Background Lumbar spinal stenosis is one of the common causes of low back and leg pain. Lumbar intervertebral disc degeneration leads to the decrease of intervertebral height, the ...
Transforaminal lumbar interbody fusion in iatrogenic lumbar instability
Transforaminal lumbar interbody fusion in iatrogenic lumbar instability
Background
Lumbosacral instability is one of the causes of failed back surgery syndrome, and it is characterized by loss of disc height with translational and in many c...
Surgical Outcomes of Lumbar Spondylolisthesis Treated with Posterior Lumbar Interbody Fusion
Surgical Outcomes of Lumbar Spondylolisthesis Treated with Posterior Lumbar Interbody Fusion
Background: Posterior lumbar interbody fusion (PLIF) involves fusing vertebrae in the lower spine with bone grafts or cages to stabilize it. This surgical solution effectively addr...
CHANGES IN RADIOGRAPHIC PARAMETERS AFTER MINIMALLY INVASIVE LUMBAR INTERBODY FUSION
CHANGES IN RADIOGRAPHIC PARAMETERS AFTER MINIMALLY INVASIVE LUMBAR INTERBODY FUSION
Objective : This study aims to evaluate changes in lumbosacral parameters after minimally invasive lumbar interbody fusion. The secondary aim was to evaluate whether interbody cage...
Perioperative Nursing Plan for Posterior Lumbar Interbody Fusion in Patients with Lumbar Spinal Stenosis Based on the Enhanced Recovery After Surgery Concept
Perioperative Nursing Plan for Posterior Lumbar Interbody Fusion in Patients with Lumbar Spinal Stenosis Based on the Enhanced Recovery After Surgery Concept
Objective:To evaluate the impact of perioperative nursing plans based on enhanced recovery after surgery on the recoveryof patients undergoing posterior lumbar interbody fusion sur...