Influence of fire-ignition methods and stove ventilation rates on gaseous and particle emissions from residential coal braziers
View through CrossRef
Despite extensive electrification of low-income residential areas on the South African Highveld, extensive use is still made of wood and coal as domestic fuels, particularly for winter space heating. In informal settlements characterised by poverty and lacking electrification, coal is combusted in non-standardised, inefficient and polluting metal braziers, colloquially known as imbaulas. Copious emissions from domestic coal fires result in elevated household and ambient air pollution levels well above national air quality limits. Despite the severity of this pollution as a public health issue, emissions data from residential coal-burning braziers are still scarce. Consequently, there is a need to evaluate the emission characteristics of these devices. In this paper, we report on controlled combustion experiments carried out to investigate systematically influences of fire-ignition methods and stove ventilation rates on gaseous and condensed matter (smoke) emissions from informal residential coal combustion braziers. Two methods of stove ignition—conventional bottom-lit updraft (BLUD) and the top-lit updraft (TLUD) (colloquially known as the Basa njengo Magogo) were investigated. Emission factors (EFs) were found to be dependent on fire ignition method and stove ventilation rates. The top-lit ignition method reduces PM10/PM2.5 by 76% to 80% compared to the BLUD method. Carbon monoxide emissions do not change significantly with the ignition method. Pollutant emissions from normal combustion in high ventilation conditions were low compared to pollutants emitted when an oxygen deficient atmosphere was created under low ventilation conditions. High stove ventilation rates resulted in a 50% reduction in PM10/PM2.5 emissions compared to the low ventilation rates. Emissions of gaseous and particulate matter from incomplete combustion can be minimised by design optimisation of the braziers. Ideally, the emissions of condensed matter particles (which form the bulk of emitted particles in residential coal fires) can be reduced through good mixing of emitted gases and air, and by ensuring a long residence time in the high temperature oxygen rich post combustion zone, to allow for complete oxidation. This study is significant in that it presents the first systematic and comprehensive study of factors affecting emissions from coal braziers.
Academy of Science of South Africa
Title: Influence of fire-ignition methods and stove ventilation rates on gaseous and particle emissions from residential coal braziers
Description:
Despite extensive electrification of low-income residential areas on the South African Highveld, extensive use is still made of wood and coal as domestic fuels, particularly for winter space heating.
In informal settlements characterised by poverty and lacking electrification, coal is combusted in non-standardised, inefficient and polluting metal braziers, colloquially known as imbaulas.
Copious emissions from domestic coal fires result in elevated household and ambient air pollution levels well above national air quality limits.
Despite the severity of this pollution as a public health issue, emissions data from residential coal-burning braziers are still scarce.
Consequently, there is a need to evaluate the emission characteristics of these devices.
In this paper, we report on controlled combustion experiments carried out to investigate systematically influences of fire-ignition methods and stove ventilation rates on gaseous and condensed matter (smoke) emissions from informal residential coal combustion braziers.
Two methods of stove ignition—conventional bottom-lit updraft (BLUD) and the top-lit updraft (TLUD) (colloquially known as the Basa njengo Magogo) were investigated.
Emission factors (EFs) were found to be dependent on fire ignition method and stove ventilation rates.
The top-lit ignition method reduces PM10/PM2.
5 by 76% to 80% compared to the BLUD method.
Carbon monoxide emissions do not change significantly with the ignition method.
Pollutant emissions from normal combustion in high ventilation conditions were low compared to pollutants emitted when an oxygen deficient atmosphere was created under low ventilation conditions.
High stove ventilation rates resulted in a 50% reduction in PM10/PM2.
5 emissions compared to the low ventilation rates.
Emissions of gaseous and particulate matter from incomplete combustion can be minimised by design optimisation of the braziers.
Ideally, the emissions of condensed matter particles (which form the bulk of emitted particles in residential coal fires) can be reduced through good mixing of emitted gases and air, and by ensuring a long residence time in the high temperature oxygen rich post combustion zone, to allow for complete oxidation.
This study is significant in that it presents the first systematic and comprehensive study of factors affecting emissions from coal braziers.
Related Results
Influence of fire-ignition methods and stove ventilation rates on gaseous and particle emissions from residential coal braziers
Influence of fire-ignition methods and stove ventilation rates on gaseous and particle emissions from residential coal braziers
Despite extensive electrification of low-income residential areas on the South African Highveld, extensive use is still made of wood and coal as domestic fuels, particularly for wi...
Ceramic Braziers Found at the Bronze Age Monuments of Azerbaijan
Ceramic Braziers Found at the Bronze Age Monuments of Azerbaijan
During the excavations of the Bronze Age archaeological sites in Azerbaijan, clay braziers were found among the artifacts revealed in the residential areas and, very rarely, in the...
Emission factors of domestic coal-burning braziers
Emission factors of domestic coal-burning braziers
We present experimental results of emission factors from a suite of domestic coal-burning braziers (lab fabricated and field collected) that span the possible range of real-world u...
Research on water immersion damage characteristics and equivalent width of coal pillar
Research on water immersion damage characteristics and equivalent width of coal pillar
Abstract
Affected by weakening effect of water in the goaf, the bearing capacity of coal pillar reduced, and coal pillar rock burst is prone to occur, which is a serious th...
The quest for the smoking gun
The quest for the smoking gun
Around one-third of the global population relies on solid fuels like coal, wood, and plant residue for cooking and heating, the household air pollution (HAP) resulted from which ha...
Influence of coal properties on the performance of fixed-bed coal-burning braziers
Influence of coal properties on the performance of fixed-bed coal-burning braziers
Informal fixed-bed coal-burning braziers are used extensively in low-income communities of South Africa for space-heating and cooking needs. An investigation was carried out on the...
The CO2 storage in coal seams at the influence of coal fines migration
The CO2 storage in coal seams at the influence of coal fines migration
Abstract: the pressure of the coal seam decays to a certain value due to the production of CH4, the production wells are switched to CO2 injection wells. The injection of CO2 can i...