Javascript must be enabled to continue!
High Resolution SelfA Rotary Table by the Interpolation Signal Calibration
View through CrossRef
Self-A (Self-calibratable Angle device) rotary encoder can detect some kinds of angle error, not only its encoder scale error, but also the encoder attachment error (e.g. eccentricity error). When rotary table with built-in Self-A encoder rotates only one revolution, inner Self-A rotary encoder can calibrate the own angle error with a high accuracy. However, in the case of the Self-A using the encoder of 36,000 graduation scales, since the angular interval of the calibrated main scales corresponds to 36", it is insufficient for high resolution angular indexing control with high accuracy. Generally, the angle error of electric interpolation signal is estimated to be 1 % of main scale resolution that corresponds to about 0.36" for 36,000 scales encoder. Accordingly, even if Self-A had the ability which can calibrate in the accuracy 0.1", when it was controlling the rotary table using an electric interpolation signal, its total accuracy worsened to about 0.36". For improvement in precise angular-position control, we developed Self-A rotary table which can calibrate the angle signal at high resolution including electric interpolation signals. In this paper, we introduce the performance of the new high resolution Self-A encoder table. It keeps high accuracy and good repeatability in the 360° whole range as well as in the short range of ±1,000".
Trans Tech Publications, Ltd.
Title: High Resolution SelfA Rotary Table by the Interpolation Signal Calibration
Description:
Self-A (Self-calibratable Angle device) rotary encoder can detect some kinds of angle error, not only its encoder scale error, but also the encoder attachment error (e.
g.
eccentricity error).
When rotary table with built-in Self-A encoder rotates only one revolution, inner Self-A rotary encoder can calibrate the own angle error with a high accuracy.
However, in the case of the Self-A using the encoder of 36,000 graduation scales, since the angular interval of the calibrated main scales corresponds to 36", it is insufficient for high resolution angular indexing control with high accuracy.
Generally, the angle error of electric interpolation signal is estimated to be 1 % of main scale resolution that corresponds to about 0.
36" for 36,000 scales encoder.
Accordingly, even if Self-A had the ability which can calibrate in the accuracy 0.
1", when it was controlling the rotary table using an electric interpolation signal, its total accuracy worsened to about 0.
36".
For improvement in precise angular-position control, we developed Self-A rotary table which can calibrate the angle signal at high resolution including electric interpolation signals.
In this paper, we introduce the performance of the new high resolution Self-A encoder table.
It keeps high accuracy and good repeatability in the 360° whole range as well as in the short range of ±1,000".
Related Results
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Abstract
Aiming at the problems of fast wear and short service life of rotary tillage blade in gneiss mountainous area, and the lack of accurate and reliable discrete eleme...
SYSTEMATIZATION OF INTERPOLATION METHODS IN GEOMETRIC MODELING
SYSTEMATIZATION OF INTERPOLATION METHODS IN GEOMETRIC MODELING
This article proposes to show the connections between the practical problems of geometric modeling, for the solution of which there are no adequate interpolation methods. Interpola...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
MODAL ANALISIS PADA ROTARY KILN DENGAN MENGGUNAKAN METODE ELEMEN HINGGA
MODAL ANALISIS PADA ROTARY KILN DENGAN MENGGUNAKAN METODE ELEMEN HINGGA
This research is based on the general damage to the rotary kiln due to continuous use. Then the results from the burned in a Rotary Kiln So we need a prevention to overcome it. Tes...
A Dynamic Analysis of the Rotary Cutting System of King Grass Shredder
A Dynamic Analysis of the Rotary Cutting System of King Grass Shredder
With the rotary cutting system of king grass shredder as the research object, this paper established finite element models for rotating shaft, rotating shaft-belt pulley, rotating ...
A FAST MORPHING-BASED INTERPOLATION FOR MEDICAL IMAGES: APPLICATION TO CONFORMAL RADIOTHERAPY
A FAST MORPHING-BASED INTERPOLATION FOR MEDICAL IMAGES: APPLICATION TO CONFORMAL RADIOTHERAPY
A method is presented for fast interpolation between medical images. The method is intended for both slice and projective interpolation. It allows offline interpolation between nei...
A Spatiotemporal data Fusion method for generating a high-resolution, regular and cloud-free time series of satellite images
A Spatiotemporal data Fusion method for generating a high-resolution, regular and cloud-free time series of satellite images
<p>Scientific research of land surface dynamics in heterogeneous landscapes often require remote sensing data with high resolutions in both space and time. However, s...
Efficient and Effective Gas Sensor Calibration with Randomized Gas Mixtures
Efficient and Effective Gas Sensor Calibration with Randomized Gas Mixtures
Introduction
The selective quantification of target gases in complex mixtures is an important part of numerous applications of chemical gas sensors. ...