Javascript must be enabled to continue!
Development and Baseline Comparison of a New Pulsed-Neutron Spectroscopy Tool for Carbon- Oxygen Analysis and Three-Phase Saturation Monitoring
View through CrossRef
A new slim multidetector pulsed-neutron wireline-logging tool has been developed for openhole or casedhole formation evaluation saturation analysis and time-lapse monitoring. With a greater neutron source output and high-spectral resolution gamma ray detectors, the tool can be operated with reduced uncertainty or faster logging speeds. New, fully programable digital electronics provide a range of acquisition modes optimized for specific formation evaluation objectives. Neutrons are generated from a high-output pulsed-neutron generator, which propagates radially outward, passing through the borehole, completion material, and into the formation. Energy is lost through scattering, and neutrons are absorbed by the surrounding material. Gamma rays are emitted from scattering and absorption interactions at discrete energies, which can be measured by one of three spectral gamma scintillation detectors. The energy distribution of these incident gamma rays by inelastic and capture interactions is affected by the elemental composition of the material. A salinity-independent oil-water saturation assessment begins with the deconvolution of neutron-induced gamma ray inelastic spectra into constituent elemental components. Carbon-oxygen ratios (C/O) of elemental yields are then compared to a reference model to determine the relative saturation and porosity-filled volume of oil and water. In PNC (pulsed-neutron capture) acquisition mode, a salinity-dependent oil-water saturation assessment is determined from neutron capture cross section (sigma) measurements, which are compared to formation and porosity fluids using a mass balance approach. Gas saturation assessment is determined from gas-sensitive inelastic (RIN13) and capture (RATO13) ratios. Gas ratios are compared to a reference model to assess the relative saturation of fluids, typically distinguishing gas from water or gas from oil. Gas saturation is not limited to hydrocarbon components and can also be used for saturation analysis of H2, He, CO2, N2, and other non-hydrocarbon-bearing components. A new Omni-mode acquisition combining simultaneous PNC and C/O measurements was also developed. This acquisition mode provides advantages in reducing multipass logging typically required from separate PNC and C/O acquisitions. By including PNC neutron capture sigma, gas-sensitive neutron capture and inelastic measurements, and C/O inelastic measurements, the simultaneous Omni-mode (PNC+C/O) acquisition is specifically optimized for three-phase saturation analysis applications, including baseline CO2 sequestration evaluation for carbon capture, utilization, and storage (CCUS) CO2 and steamflood time-lapse monitoring. Results from a field example are presented to demonstrate the new technology with spectral C/O saturation analysis compared to traditional windows C/O analysis and to compare the performance of the next-generation tool to the legacy tool. Multiphase saturations from C/O and RIN13 measurements and compatibility with legacy interpretations for time-lapse saturation monitoring are also presented.
Society of Petrophysicists and Well Log Analysts (SPWLA)
Title: Development and Baseline Comparison of a New Pulsed-Neutron Spectroscopy Tool for Carbon- Oxygen Analysis and Three-Phase Saturation Monitoring
Description:
A new slim multidetector pulsed-neutron wireline-logging tool has been developed for openhole or casedhole formation evaluation saturation analysis and time-lapse monitoring.
With a greater neutron source output and high-spectral resolution gamma ray detectors, the tool can be operated with reduced uncertainty or faster logging speeds.
New, fully programable digital electronics provide a range of acquisition modes optimized for specific formation evaluation objectives.
Neutrons are generated from a high-output pulsed-neutron generator, which propagates radially outward, passing through the borehole, completion material, and into the formation.
Energy is lost through scattering, and neutrons are absorbed by the surrounding material.
Gamma rays are emitted from scattering and absorption interactions at discrete energies, which can be measured by one of three spectral gamma scintillation detectors.
The energy distribution of these incident gamma rays by inelastic and capture interactions is affected by the elemental composition of the material.
A salinity-independent oil-water saturation assessment begins with the deconvolution of neutron-induced gamma ray inelastic spectra into constituent elemental components.
Carbon-oxygen ratios (C/O) of elemental yields are then compared to a reference model to determine the relative saturation and porosity-filled volume of oil and water.
In PNC (pulsed-neutron capture) acquisition mode, a salinity-dependent oil-water saturation assessment is determined from neutron capture cross section (sigma) measurements, which are compared to formation and porosity fluids using a mass balance approach.
Gas saturation assessment is determined from gas-sensitive inelastic (RIN13) and capture (RATO13) ratios.
Gas ratios are compared to a reference model to assess the relative saturation of fluids, typically distinguishing gas from water or gas from oil.
Gas saturation is not limited to hydrocarbon components and can also be used for saturation analysis of H2, He, CO2, N2, and other non-hydrocarbon-bearing components.
A new Omni-mode acquisition combining simultaneous PNC and C/O measurements was also developed.
This acquisition mode provides advantages in reducing multipass logging typically required from separate PNC and C/O acquisitions.
By including PNC neutron capture sigma, gas-sensitive neutron capture and inelastic measurements, and C/O inelastic measurements, the simultaneous Omni-mode (PNC+C/O) acquisition is specifically optimized for three-phase saturation analysis applications, including baseline CO2 sequestration evaluation for carbon capture, utilization, and storage (CCUS) CO2 and steamflood time-lapse monitoring.
Results from a field example are presented to demonstrate the new technology with spectral C/O saturation analysis compared to traditional windows C/O analysis and to compare the performance of the next-generation tool to the legacy tool.
Multiphase saturations from C/O and RIN13 measurements and compatibility with legacy interpretations for time-lapse saturation monitoring are also presented.
Related Results
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Development and Baseline Comparison of a New Pulsed-Neutron Spectroscopy Tool for Carbon- Oxygen Analysis and Three-Phase Saturation Monitoring
Development and Baseline Comparison of a New Pulsed-Neutron Spectroscopy Tool for Carbon- Oxygen Analysis and Three-Phase Saturation Monitoring
A new multidetector pulsed-neutron logging tool is introduced. Pulsed-neutron capture (PNC) and carbon/oxygen (C/O) measurements from pulsed-neutron logging tools are used as part ...
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
In our previous research which has published in 62th SPWLA symposium, a numerical simulation method was proposed which about the double particle detector CLYC (Cs2LiYCl6:CE) to get...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Abstract
Introduction
Cancer is one of the major medical problems threatening human health. Breast cancer ...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract
The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
Three-Phase Saturation Evaluation Using Advanced Pulsed Neutron Measurement
Three-Phase Saturation Evaluation Using Advanced Pulsed Neutron Measurement
Abstract
Accurately monitoring saturation change mechanisms requires adequate surveillance methods and techniques. We present a methodology to evaluate three-phase s...

