Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Application of Lyon Consensus criteria for GORD diagnosis: evaluation of conventional and new impedance-pH parameters

View through CrossRef
Objective To validate Lyon Consensus criteria for diagnosing gastro-oesophageal reflux disease (GORD) by reflux monitoring. Design Manual review of impedance-pH tracings from patients with proton pump inhibitor (PPI)-dependent heartburn, evaluated off PPI. Acid exposure time (AET) thresholds defined by the Lyon Consensus and impedance parameters were investigated, namely, total refluxes (TRs), postreflux swallow-induced peristaltic wave (PSPW) index and mean nocturnal baseline impedance (MNBI). Results The study included 488 patients, 178 (36%) with normal (<4%) AET, 89 (18%) with inconclusive (4%–6%) AET and 221 (45%) with abnormal (>6%) AET, alongside with 70 healthy controls. At receiver operating characteristic analysis, area under curve was 0.89, 0.95 and 0.89 for TRs, PSPW index and MNBI, respectively, and threshold values were 40, 50% and 2000 Ω; the 4% physiological AET threshold defined by the Lyon Consensus showed 100% specificity but 63% sensitivity. The thresholds defined for impedance parameters were validated against AET by means of ordered logistic regression, being in concordance with the 4% AET threshold (OR 2.5 for TRs, 18.9 for PSPW index and 5.7 for MNBI). TRs positivity and concordant PSPW index/MNBI positivity were found in 80%–90% of patients in the abnormal AET group, in 73%–74% of cases in the inconclusive AET group and in 28%–40% of cases in the group with normal AET. Conclusions Our results show the overall validity of the Lyon Consensus approach to GORD diagnosis. Adding evaluation of impedance parameters, namely, TRs, PSPW index and MNBI to AET appraisal, substantially improves the diagnostic yield of reflux monitoring.
Title: Application of Lyon Consensus criteria for GORD diagnosis: evaluation of conventional and new impedance-pH parameters
Description:
Objective To validate Lyon Consensus criteria for diagnosing gastro-oesophageal reflux disease (GORD) by reflux monitoring.
Design Manual review of impedance-pH tracings from patients with proton pump inhibitor (PPI)-dependent heartburn, evaluated off PPI.
Acid exposure time (AET) thresholds defined by the Lyon Consensus and impedance parameters were investigated, namely, total refluxes (TRs), postreflux swallow-induced peristaltic wave (PSPW) index and mean nocturnal baseline impedance (MNBI).
Results The study included 488 patients, 178 (36%) with normal (<4%) AET, 89 (18%) with inconclusive (4%–6%) AET and 221 (45%) with abnormal (>6%) AET, alongside with 70 healthy controls.
At receiver operating characteristic analysis, area under curve was 0.
89, 0.
95 and 0.
89 for TRs, PSPW index and MNBI, respectively, and threshold values were 40, 50% and 2000 Ω; the 4% physiological AET threshold defined by the Lyon Consensus showed 100% specificity but 63% sensitivity.
The thresholds defined for impedance parameters were validated against AET by means of ordered logistic regression, being in concordance with the 4% AET threshold (OR 2.
5 for TRs, 18.
9 for PSPW index and 5.
7 for MNBI).
TRs positivity and concordant PSPW index/MNBI positivity were found in 80%–90% of patients in the abnormal AET group, in 73%–74% of cases in the inconclusive AET group and in 28%–40% of cases in the group with normal AET.
Conclusions Our results show the overall validity of the Lyon Consensus approach to GORD diagnosis.
Adding evaluation of impedance parameters, namely, TRs, PSPW index and MNBI to AET appraisal, substantially improves the diagnostic yield of reflux monitoring.

Related Results

Knowledge of Gastroesophageal Reflux Disease among Dental Practitioners in Nigeria
Knowledge of Gastroesophageal Reflux Disease among Dental Practitioners in Nigeria
Background: Gastroesophageal reflux disease (GORD) is the clinical condition that develops when the reflux of gastric contents into the oesophagus leads to troublesome symptoms and...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Is internal anal sphincter degeneration associated with lower oesophageal sphincter dysfunction?
Is internal anal sphincter degeneration associated with lower oesophageal sphincter dysfunction?
Introduction Internal anal sphincter (IAS) degeneration is the cause of up to 13% of faecal incontinence referrals to a tertiary centre. The authors speculated ...
Applying Lyon Consensus criteria in the work‐up of patients with proton pump inhibitory‐refractory heartburn
Applying Lyon Consensus criteria in the work‐up of patients with proton pump inhibitory‐refractory heartburn
SummaryBackgroundA hierarchical approach for gastro‐oesophageal reflux disease (GERD) diagnosis by impedance‐pH monitoring was proposed by the Lyon Consensus, based on acid exposur...
Sondes à impédance mutuelle pour plateformes nanosatellite
Sondes à impédance mutuelle pour plateformes nanosatellite
Mutual impedance probes for nanosatellite platforms Les sondes à impédance mutuelle sont des expériences spatiales de diagnostic utilisées pour mesurer in situ la d...

Back to Top