Javascript must be enabled to continue!
Chiral Separation of Diastereoisomers of Cefuroxime Axetil by High-Performance Thin-Layer Chromatography
View through CrossRef
Abstract
Conditions for separation and determination of diastereoisomers of cefuroxime axetil by HPTLC on cellulose layers with densitometry were developed. A good separation of the constituents was achieved using a mobile phase composed of 1 aqueous -cyclodextrinmethanol (15 + 1, v/v). For detecting spots on the chromatograms, densitometric measurements were used at 285 nm. The method is characterized by high sensitivity; the LOD was 0.04 g/spot and LOQ was 0.11 g/spot for both forms of the cefuroxime axetil diastereoisomers. For the individual diastereoisomers, high recovery values from 96.63 to 104.16 were obtained. Identification of the diastereoisomers was performed by 1H-NMR spectrometric analysis.
Title: Chiral Separation of Diastereoisomers of Cefuroxime Axetil by High-Performance Thin-Layer Chromatography
Description:
Abstract
Conditions for separation and determination of diastereoisomers of cefuroxime axetil by HPTLC on cellulose layers with densitometry were developed.
A good separation of the constituents was achieved using a mobile phase composed of 1 aqueous -cyclodextrinmethanol (15 + 1, v/v).
For detecting spots on the chromatograms, densitometric measurements were used at 285 nm.
The method is characterized by high sensitivity; the LOD was 0.
04 g/spot and LOQ was 0.
11 g/spot for both forms of the cefuroxime axetil diastereoisomers.
For the individual diastereoisomers, high recovery values from 96.
63 to 104.
16 were obtained.
Identification of the diastereoisomers was performed by 1H-NMR spectrometric analysis.
Related Results
A multicenter, randomized study comparing the efficacy and safety of intravenous and/or oral levofloxacin versus ceftriaxone and/or cefuroxime axetil in treatment of adults with community-acquired pneumonia
A multicenter, randomized study comparing the efficacy and safety of intravenous and/or oral levofloxacin versus ceftriaxone and/or cefuroxime axetil in treatment of adults with community-acquired pneumonia
Five hundred ninety patients were enrolled in a prospective, multicenter, randomized trial comparing the efficacy and safety of 7 to 14 days of levofloxacin treatment with that of ...
Advances on broadband and resonant chiral metasurfaces
Advances on broadband and resonant chiral metasurfaces
Abstract
Chirality describes mirror symmetry breaking in geometric structures or certain physical quantities. The interaction between chiral structure and chiral ...
Comparative Bioavailability of Cefuroxime Axetil from Tablets and Self-Microemulsifying Drug Delivery Systems in Rats
Comparative Bioavailability of Cefuroxime Axetil from Tablets and Self-Microemulsifying Drug Delivery Systems in Rats
Cefuroxime axetil has poor bioavailability due to low solubility. This can be surmounted by preparing the drug by self-microemulsifying drug delivery system (SMEDDS). In this study...
Chiral Ionic Liquids as Stationary Phases in Electrophoretic Separations
Chiral Ionic Liquids as Stationary Phases in Electrophoretic Separations
Ionic liquids (ILs) are exceptional solvents having melting points at or
below 100 0C. They are completely made up of ions, often consisting of an organic
cation and an inorganic o...
Advancing Cefuroxime Axetil through Nanotechnology: Enhancing Its Effectiveness
Advancing Cefuroxime Axetil through Nanotechnology: Enhancing Its Effectiveness
Cefuroxime axetil, a second-generation cephalosporin antibiotic, has long been utilized to treat various bacterial infections. However, recent advances in nanotechnology have provi...
Chiral Chromatography and Artificial Intelligence Integration in Enantiomers Separation
Chiral Chromatography and Artificial Intelligence Integration in Enantiomers Separation
ABSTRACT
Chiral chromatography is the most sensitive technique in separation science due to the similar properties of the enantiomers, which require highly expert...
COMPARATIVE EFFICACY OF INTRACAMERAL 0.5% MOXIFLOXACIN VERSUS 0.1% CEFUROXIME IN PREVENTING POSTOPERATIVE ENDOPHTHALMITIS FOLLOWING PHACOEMULSIFICATION CATARACT SURGERY: A RANDOMIZED CONTROLLED TRIAL
COMPARATIVE EFFICACY OF INTRACAMERAL 0.5% MOXIFLOXACIN VERSUS 0.1% CEFUROXIME IN PREVENTING POSTOPERATIVE ENDOPHTHALMITIS FOLLOWING PHACOEMULSIFICATION CATARACT SURGERY: A RANDOMIZED CONTROLLED TRIAL
Background: Postoperative endophthalmitis is an uncommon but vision-threatening complication of cataract surgery that can result in serious ocular morbidity if not prevented or tre...
Chiral Ionic Liquids and Chromatography: Synergistic Effects in Enantioseparations
Chiral Ionic Liquids and Chromatography: Synergistic Effects in Enantioseparations
Chiral ionic liquids (CILs) are a subcategory of ionic liquids that possess a
chiral moiety. The need for chiral separations in several industries, including
pharmaceutical, food, ...