Javascript must be enabled to continue!
#1615 Working without peritoneal dialysate and urine collections during the COVID-19 pandemic: how to assure sufficient small solute removal
View through CrossRef
Abstract
Background and Aims
The guidelines of the International Society of Peritoneal Dialysis suggest regular control of small solute removal. During the COVID-19 pandemic we did not perform additional controls of dialysis adequacy in our peritoneal dialysis patients. We judged patients according symptoms and serum urea levels. In this retrospective study, we aimed to evaluate whether the measurement of serum urea alone might indicate sufficient small solute removal in peritoneal dialysis patients.
Method
In 216 adult PD patients (139 males, 77 females, median age 64 years, median BMI 26.7) Kt/V urea (renal and peritoneal) was registered together with anthropometric and laboratory data during the first two years of PD therapy. Patients presenting urea values between 100 and 250 mg/dl were included in the statistical analysis, thus resulting in the evaluation of 410 measurements (265 in male, 145 in female patients). Urea distribution volume was calculated using the formula of Watson and Watson. The measurement of urea in blood and urine was performed by a standard kinetic test with urease.
Results
Serum urea correlated significantly to Kt/V urea (r = −0.28, p < 0.01), whereas significance was not reached in female patients (male patients: r = −0.35, p < 0.01; female patients; r = −0.14, p = 0.13). Kt/V urea of at least 1.7 is achieved in male patients presenting serum urea values lower than 160 mg/dl (95% confidence interval), whereas in female patients apparently presenting serum urea values lower than 200 mg/dl (95% confidence interval). This difference is due to the distinct sex specific urea distribution volume (median value: male patients 40.8 liters, female patients 31.8 liters) and to the absence of a significant correlation between serum urea and Kt/V urea in female patients.
Conclusion
Serum urea values below 160 mg/dl in male peritoneal dialysis patients are roughly indicating sufficient small solute removal, whereas a clear relation between serum urea and Kt/V urea was not present in female patients in our study population.
Oxford University Press (OUP)
Title: #1615 Working without peritoneal dialysate and urine collections during the COVID-19 pandemic: how to assure sufficient small solute removal
Description:
Abstract
Background and Aims
The guidelines of the International Society of Peritoneal Dialysis suggest regular control of small solute removal.
During the COVID-19 pandemic we did not perform additional controls of dialysis adequacy in our peritoneal dialysis patients.
We judged patients according symptoms and serum urea levels.
In this retrospective study, we aimed to evaluate whether the measurement of serum urea alone might indicate sufficient small solute removal in peritoneal dialysis patients.
Method
In 216 adult PD patients (139 males, 77 females, median age 64 years, median BMI 26.
7) Kt/V urea (renal and peritoneal) was registered together with anthropometric and laboratory data during the first two years of PD therapy.
Patients presenting urea values between 100 and 250 mg/dl were included in the statistical analysis, thus resulting in the evaluation of 410 measurements (265 in male, 145 in female patients).
Urea distribution volume was calculated using the formula of Watson and Watson.
The measurement of urea in blood and urine was performed by a standard kinetic test with urease.
Results
Serum urea correlated significantly to Kt/V urea (r = −0.
28, p < 0.
01), whereas significance was not reached in female patients (male patients: r = −0.
35, p < 0.
01; female patients; r = −0.
14, p = 0.
13).
Kt/V urea of at least 1.
7 is achieved in male patients presenting serum urea values lower than 160 mg/dl (95% confidence interval), whereas in female patients apparently presenting serum urea values lower than 200 mg/dl (95% confidence interval).
This difference is due to the distinct sex specific urea distribution volume (median value: male patients 40.
8 liters, female patients 31.
8 liters) and to the absence of a significant correlation between serum urea and Kt/V urea in female patients.
Conclusion
Serum urea values below 160 mg/dl in male peritoneal dialysis patients are roughly indicating sufficient small solute removal, whereas a clear relation between serum urea and Kt/V urea was not present in female patients in our study population.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Abstract B140: Autologous human growing tumor model and its immunological relevance for cancer immunology research
Abstract B140: Autologous human growing tumor model and its immunological relevance for cancer immunology research
Abstract
Background: Tumors grow in accordance with immunoediting. If we can see the changes of immune characteristics in the microenvironment during tumor growth, w...
Osteopontin levels in the drained dialysate reflect the peritoneal solute transport rate
Osteopontin levels in the drained dialysate reflect the peritoneal solute transport rate
Abstract
Background and objectives: Long-term peritoneal dialysis (PD) is accompanied by low-grade intraperitoneal inflammation, may eventually lead to peritoneal membrane ...
A STUDY ON DIALYSATE GLUCOSE CONCENTRATION IN PATIENTS WITH CONTINUOUS AMBULATORY PERITONEAL DIALYSIS
A STUDY ON DIALYSATE GLUCOSE CONCENTRATION IN PATIENTS WITH CONTINUOUS AMBULATORY PERITONEAL DIALYSIS
Background: Glucose-based peritoneal dialysis (PD) is the predominantly used dialysate in PD patients. Glucose absorption in peritoneal dialysis (PD) patients may contribute to adv...
Burden of the Beast
Burden of the Beast
Introduction
Throughout the COVID-19 pandemic, and its fluctuating waves of infections and the emergence of new variants, Indigenous populations in Australia and worldwide have re...
Comparison of Two Different Kt/V Methods in Continuous Ambulatory Peritoneal Dialysis Patients
Comparison of Two Different Kt/V Methods in Continuous Ambulatory Peritoneal Dialysis Patients
Dialysis adequacy has gained particular interest for the assessment of the quality of dialysis in patients undergoing hemodialysis (HD) and continuous ambulatory peritoneal dialysi...
Hyaluronan reduces colitis-induced intraperitoneal inflammation during peritoneal dialysis
Hyaluronan reduces colitis-induced intraperitoneal inflammation during peritoneal dialysis
Background: Peritoneal dialysis induces the inflammatory response within the peritoneal cavity, which contributes to the progressive damage of the peritoneum. Due to close contact ...