Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Effect of Patient Positioning on Intraoperative Neuromonitoring During Thyroid and Parathyroid Surgery

View through CrossRef
Background Intraoperative neuromonitoring (IONM) has been accepted as a routine adjunct among surgeons who perform thyroid and parathyroid surgeries. Thyroid and parathyroid surgeries use various patient positioning strategies that have poorly understood effects on IONM. The aim of this study was to compare IONM signals between the transaxillary and transcervical approaches. Methods In this retrospective cohort study, we evaluated 463 adult patients who underwent a total of 502 procedures. The procedures performed included total thyroidectomy, right or left hemithyroidectomy, and parathyroidectomy. Vagus nerve and recurrent laryngeal nerve (RLN) latency and amplitude measurements were analyzed intra-operatively. The distances between the vagus nerve and the trachea were measured via ultrasound during transaxillary procedures. Results Compared to the transcervical approach, the right vagus nerve latency was significantly decreased in the transaxillary approach. Transaxillary surgery was not associated with increased latency or decreased amplitude on IONM. The distance between the vagus nerve and trachea was significantly decreased post-positioning during transaxillary approaches. Discussion Despite differences in patient positioning, a transaxillary approach was not associated with increased stress on the vagus nerve or RLN, according to IONM data. The decreased right vagus nerve latency associated with a transaxillary approach highlights the importance of considering patient positioning and laterality while interpreting IONM data.
Title: The Effect of Patient Positioning on Intraoperative Neuromonitoring During Thyroid and Parathyroid Surgery
Description:
Background Intraoperative neuromonitoring (IONM) has been accepted as a routine adjunct among surgeons who perform thyroid and parathyroid surgeries.
Thyroid and parathyroid surgeries use various patient positioning strategies that have poorly understood effects on IONM.
The aim of this study was to compare IONM signals between the transaxillary and transcervical approaches.
Methods In this retrospective cohort study, we evaluated 463 adult patients who underwent a total of 502 procedures.
The procedures performed included total thyroidectomy, right or left hemithyroidectomy, and parathyroidectomy.
Vagus nerve and recurrent laryngeal nerve (RLN) latency and amplitude measurements were analyzed intra-operatively.
The distances between the vagus nerve and the trachea were measured via ultrasound during transaxillary procedures.
Results Compared to the transcervical approach, the right vagus nerve latency was significantly decreased in the transaxillary approach.
Transaxillary surgery was not associated with increased latency or decreased amplitude on IONM.
The distance between the vagus nerve and trachea was significantly decreased post-positioning during transaxillary approaches.
Discussion Despite differences in patient positioning, a transaxillary approach was not associated with increased stress on the vagus nerve or RLN, according to IONM data.
The decreased right vagus nerve latency associated with a transaxillary approach highlights the importance of considering patient positioning and laterality while interpreting IONM data.

Related Results

Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Abstract Introduction Non-Hodgkin lymphoma (NHL) of the thyroid, a rare malignancy linked to autoimmune disorders, is poorly understood in terms of its pathogenesis and treatment o...
Thyroid Hemiagenesis: A Single-Center Case Series
Thyroid Hemiagenesis: A Single-Center Case Series
Abstract Introduction: Thyroid hemiagenesis (TH) is a rare congenital anomaly characterized by the complete absence of one thyroid lobe, with or without absence of the isthmus. Its...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Unusual Metastasis from Follicular Thyroid Carcinoma: A Case Report and Literature Review
Unusual Metastasis from Follicular Thyroid Carcinoma: A Case Report and Literature Review
Abstract Introduction Follicular thyroid carcinoma (FTC) is a type of well-differentiated thyroid carcinoma. It has a poorer prognosis, is more metastatic, and has characteristics ...
Clinicopathological Features of Indeterminate Thyroid Nodules: A Single-center Cross-sectional Study
Clinicopathological Features of Indeterminate Thyroid Nodules: A Single-center Cross-sectional Study
Abstract Introduction Due to indeterminate cytology, Bethesda III is the most controversial category within the Bethesda System for Reporting Thyroid Cytopathology. This study exam...
Hyalinizing Trabecular Tumor: A Case Series with Literature Review
Hyalinizing Trabecular Tumor: A Case Series with Literature Review
Abstract Introduction: Hyalinizing trabecular tumor (HTT) is a rare thyroid neoplasm originating from follicular cells and poses diagnostic challenges due to its cytologic and hist...
The calcium-sensing receptor regulates parathyroid hormone gene expression in transfected HEK293 cells
The calcium-sensing receptor regulates parathyroid hormone gene expression in transfected HEK293 cells
Abstract Background The parathyroid calcium receptor determines parathyroid hormone secretion and the response of parathyroid hormone gene expr...

Back to Top